4
Installation room requirements
Danger
Sealed vents result in a lack of combustion air.
This leads to incomplete combustion and the
formation of life threatening carbon monoxide.
Never cover or close existing vents.
Do not make any subsequent modifications to
the building characteristics that could affect safe
operation (e.g. cable/pipework routing, cladding
or partitions).
Danger
Easily flammable liquids and materials (e.g. pet-
rol, solvents, cleaning agents, paints or paper)
can cause deflagration and fire.
Never store or use such materials in the boiler
room or in direct proximity to the heating sys-
tem.
!
Please note
Incorrect ambient conditions can lead to heating
system damage and can put safe operation at
risk.
■
Ensure ambient temperatures are above 0 °C
and below 35 °C.
■
Prevent air contamination by halogenated
hydrocarbons (e.g. as contained in paints, sol-
vents or cleaning fluids) and excessive dust
(e.g. through grinding/polishing work).
■
Avoid continuously high humidity levels (e.g.
through continuous drying of washing).
Extractors
The operation of appliances that extract air to the out-
side (cooker hoods, extractors, air conditioning units,
etc.) can create negative pressure. If the boiler is oper-
ated at the same time, this can lead to reverse flow of
the flue gas.
Danger
The simultaneous operation of the boiler and
appliances that extract air to the outside can
result in life threatening poisoning due to
reverse flow of the flue gas.
Take suitable steps to ensure an adequate sup-
ply of combustion air. If necessary, contact your
contractor.
Auxiliary components, spare and wearing parts
!
Please note
Components not tested with the heating system
may damage the system or affect its function.
Only allow qualified contractors to carry out
installation or replacement work.
Safety instructions
For your safety
(cont.)
5839324