38
Vitotrol 300-E
Rated voltage
■
Plug-in power supply unit: 5 V
■
Power supply unit for flush mounting: 12 V
Rated current
■
Plug-in power supply unit: 0.8 A
■
Power supply unit for flush mounting: 0.33 A
Internet protocol
IPv4
IP assignment
DHCP
Power consumption
4 W
Protection class
III
IP rating
IP 20D to EN 60529, ensure through design/installation.
WiFi
WiFi frequency
2.4 GHz
WiFi encryption
Unencrypted or WPA2
Frequency band
2400.0 to 2483.5 MHz
Max. transmitting power
0.1 W (e.i.r.p.)
Low Power Radio Status
Radio frequency
2.4 GHz
Encryption
Encrypted
Wireless range through walls
Up to 14 m (depending on wall thickness and wall type)
Permissible ambient temperature
■
Operation
+5 to +40 °C
Installation in living spaces or boiler rooms (standard ambient con-
ditions)
■
Storage and transport
–
20 to +60 °C
Plug-in power supply unit
Rated voltage
100 to 240 V~
Rated frequency
50/60 Hz
Output voltage
5 V
Output current
2 A
Protection class
II
Permissible ambient temperature
■
Operation
5 to +40 °C
Installation in living spaces or boiler rooms (standard ambient con-
ditions)
■
Storage and transport
–
20 to +60 °C
Specification
Specification
5839615
Appendix
Summary of Contents for Vitotrol 300-E
Page 42: ...42 Certification Certification 5839615 Appendix ...
Page 45: ...45 5839615 ...
Page 46: ...46 5839615 ...