19
Standard menu
Press
"Heating circuit 1"
; the display
changes to
"Heating circuit 2"
.
Each time you press
"Heating cir-
cuit ..."
, the display changes to the next
heating circuit.
Note
The standard menu shows the informa-
tion on the heating circuit that was last
selected.
Setting the room temperature
Setting the room temperature for standard heating mode
Factory setting (Vitotronic control unit):
20 °C
Standard menu
1.
"Heating circuit 1"
,
"Heating circuit
2"
or
"Heating circuit 3"
.
2.
+/–
for the required value.
3.
"OK"
to confirm.
Setting the room temperature for reduced heating mode (night
setback)
Factory setting (Vitotronic control unit):
3 °C
Extended menu
1.
"Menu"
2.
"Heating"
3.
"Heating circuit 1"
,
"Heating circuit
2"
or
"Heating circuit 3"
.
4.
"Red. set room temperature"
5.
+/–
for the required value.
6.
"OK"
to confirm.
The rooms are heated to this tempera-
ture:
■ Between the time phases for standard
heating mode (see page 13).
■ In the holiday program (see
page 24).
Note
Frost protection monitoring is enabled
for the boiler and DHW cylinder under
the factory setting (3 °C). The rooms are
not heated.
Central heating
Selecting a heating circuit
(cont.)