background image

2.

 

Device  Description 
 

TSGC230 divided into two parts. First circuits continually sense the surrounding Gas and second 
use to send data to mobile App. 

 

 

TSGC230 has following things on front face 

 

Gas and Heat LED to indicate mode of Gas sensor 

 

Gas LEL LED indication. 2.5%, 5%, 7.5%, and 10% LED 

 

WIFI LED for network and device status 

 

Test Button to generate test signal to check connectivity 

 

Wifi reset button for device configuration 

 

 
 
 
 
 
 

 
 
 
 
 
 

 

 

And 5V micro USB  connector at left side for powering the device 

 

Fig 3.2 Device top 
side 

Fig 3.3 Device left 

side 

Summary of Contents for TrueSafe Gas Cloud

Page 1: ...11041 Phone No 91 9011033259 Customer Support No 91 9011033251 Email support vighnaharta in Website http www vighnaharta in Prepared By RRB Approved By JG Doc No RASS R D TSGC 230_UM Rev No 2_0 Eff Date 14 10 2020 USER MANUAL FOR TrueSafe Gas Cloud TSGC 230 FOR LPG CNG Model TSGC 230 VERSION 2 0 ...

Page 2: ... cloud in the premises 6 Fixing the unit for LPG detection 7 Locations to be avoided for installing True Safe 7 Power ON TSGC230 8 6 Operation 8 Warm up period 8 Sense mode 8 7 TSGC230 WiFi LED indications 9 8 TSGC230 reset button mode 9 9 TSGC230 WiFi configuration 9 10 TSGC230 Gas and Heat Alert on Mobile App 13 11 Do s and Don t when gas leak detect 14 12 Disclamer for Truesafe 15 ...

Page 3: ...hrough Wi Fi It is compatible with almost all type of Gas Detection like LPG CNG PNG gases It is used for detecting gas Leakage from cylinders or pipelines and send their status on Cloud This wall mounted unit is compact and designed for low cost domestic applications as well as commercial applications like hotel kitchens One TEST switch is also provided for user to ensure working status of system...

Page 4: ...ng things on front face Gas and Heat LED to indicate mode of Gas sensor Gas LEL LED indication 2 5 5 7 5 and 10 LED WIFI LED for network and device status Test Button to generate test signal to check connectivity Wifi reset button for device configuration And 5V micro USB connector at left side for powering the device Fig 3 2 Device top side Fig 3 3 Device left side ...

Page 5: ...er Supply 230V 50Hz AC to 5V 1A DC adapter Power Consumption About 0 5W LED Indication Gas Red LED Heat Yellow LED LEL Level 2 5 LEL Yellow LED 5 LEL Yellow LED 7 5 LEL Yellow LED 10 LEL Red LED WiFi network Status WiFi Blue LED Alarm Type Audible Buzzer Alarm Dimension 111 x 90 x 40 mm L x H x W Operating Temperature 0 C to 65 C Recommended Operating Conditions 10 40 C 30 95 RH Recommended Storag...

Page 6: ...er manual Identifying place for True Safe cloud in the premises Figure 1 For LPG detection Note LPG is heavier than air It has tendency to settle down Hence when you are using LPG cylinder True Safe Cloud must be installed at 30cm height from the floor Figure 1 Fig 2 For CNG PNG detection Note Natural gas LNG PNG CNG is lighter than air Hence when you are using it True Safe must be installed 30cm ...

Page 7: ...pinched in the hinges while closing the door 2 If it is mounted behind gas cylinder the cabinet for the gas must have grills in order to detect gas leak from the gas stove also Please refer the following diagram Figure 4 Locations to be avoided for installing True Safe Very near to exhaust fan By the side of a door or window In an enclosed space Many times LPG detector is mounted on the wall behin...

Page 8: ...as is dispersed alarms get reset During this mode Gas Leak and Heat LED flash alternately During Sense mode TSGC230 measures the ambient temperature and gives visual indication When the temperature rise above 60 C is detected Heat LED turns ON and audible buzzer remains ON Sr No Mode Gas Heat All LEL LED status Portal alert status 1 Warm up All LEL LEDs are OFF GAS and Heat blink together Buzzer o...

Page 9: ...sconnected ON for 1s and 1s OFF 2 WiFi Configuration Blink Faster 3 WiFi connected OFF continue 8 TSGC230 Reset Button Modes Sr No Reset button action Mode 1 Pressed and hold for 5s Device Enter in the WiFi configuration Mode WiFi LED blinks faster 9 TSGC230 WiFi Configuration 1 Install Cogcon App from the Play store 2 Registered with mobile number on the App Ensure that you have selected Smart Ho...

Page 10: ...ile Data is turned off and enter the WiFi Password Please ensure you have to be connected to your 2 4G WiFi and enter password of the same and click on Next button on the screen 8 Click on Confirm Indicator Blinking Rapidly button If you get a message Connect Device Manually with Retry and WiFi Settings after Connecting Progress click on WiFi settings and connect to COGCONS DEVICE hotspot manually...

Page 11: ......

Page 12: ...9 Please wait patiently and follow the process shown on the app 10 Once process is complete click on next till device shown on main screen ...

Page 13: ...SGC230 Gas and Heat Alert on Mobile App Generate Gas alert by pressing test button or giving Gas by Lighter Gas alert should shown on App Similarly generate heat condition heat alert should be shown on App ...

Page 14: ...ll be affected If lighter gas sprays the sensor it will cause extremely damage 3 Long time storage The sensors resistance will drift reversibly if it s stored for long time without electrify this drift is related with storage conditions Sensors should be stored in airproof bag without volatile silicon compound For the sensors with long time storage but no electrify they need long galvanical aging ...

Page 15: ...ng defect and returned within the warranty period Terms of Warranty 1 All models of TrueSafe detectors are warranted against any manufacturing defects for a period of Twelve months from the date of purchase The company shall repair replace only the part or a part which proves to be defective due to faulty material or workmanship 2 The warranty extended herein is confined only to the extent of repa...

Reviews: