6. Do’s & Don’ts When Gas Leakage Occurs 

Do’s

 

If the gas leakage is severe, it is very dangerous for anybody to enter the premises. 

 

If there is a minor/moderate gas leakage- Turn off the knob, regulators etc., to stop gas supply. 

 

Open all doors & windows. 

 

Don’ts

 

Do not panic 

 

Do not OFF/ON any electrical switch. 

 

7. Warranty

 

Realty Automation and Security Systems PVT. Ltd

 products are warranted for 

12 months subjected to following terms and condition.

 

 

 

This limited warranty covers defects in materials and workmanship in this 
product, it does not cover any malfunction occurred due to transportation, 
wrong material handling practice, wrong wiring, voltage and current fluctuations 
etc.

 

 

Consumable parts such as cables, cords, stickers etc. are not subjected to 
warranty. 

 

 

This limited warranty covers only the original purchaser of the product. The 
limited warranty is not transferable to subsequent owners or purchasers of this 
product 

 

 

The limited warranty does not assume the risk of loss during shipment.

 

 

Warranty does not include fuses, disposable batteries or the routine replacement 
of parts due to normal wear and tear of the product

 

Product warranty void if

 

 

Any damage or defects attributable to repair of the product by any person other 
than an authorized dealer, or the installation of unapproved parts on the product

 

 

LCD/LED crushed or bleeding

 

 

Warpage to the main PCB as a result of crushing

 

 

Fluid ingress as a result of submergence beyond the I.P rating specification

 

 

If not followed: proper storage, installation, calibration, use, maintenance and 
compliance with the product manual instructions and any other applicable 
recommendations of Realty Automations and Security Systems PVT. Ltd

 

Limited Warranty Liability:

 If in case, due to any reason if the product does not 

function as per the desired specifications, then the manufacturer will not be 
responsible for any liability/damages arises because of its non-function. In any case 
manufacturer will not be able to pay the compensation beyond the selling price of 
manufacturer, which need to be shown in terms of selling/buying invoice in terms 
of Indian Rupees. For exports warranty claims, invoiced date should be considered 

Summary of Contents for TrueSafe GASMon

Page 1: ...rta in Website http www vighnaharta in Prepared by HC Approved By Doc No RASS R D GASMon_UM_1_0 Rev No 1_0 Eff Date 14 10 2019 USER MANUAL FOR Gas Leak Monitor System VERSION 1 0 Mfg By Vighnaharta Technologies Pvt Ltd 2nd Floor Karanjkar Estate S N 11 11 Nanded Gaon Pune 411041 Contact no 919011033259 Landline Sales 919011033260 Email sales vighnaharta in Website http www vighnaharta in ...

Page 2: ... 1 Overview 3 Salient Features 3 2 Technical Specifications 3 3 Installation Instructions 3 Pre installation Checklist 3 Locations to be avoided for installing GASMon 4 4 Operation 4 5 Wiring Diagram 6 6 Do s Don ts When Gas Leakage Occurs 7 7 Warranty 7 ...

Page 3: ... for protecting the sounder from over heating and damage Two PFC outputs for interfacing the other systems LED Indications for MAINS ON SYSTEM HEALTHY ZONE 1 2 3 4 ALARM SILENCE Easy installation operation and maintenance free MS sheet housing and powder coated enclosure 2 Technical Specifications Electric specification Operating Voltage 220V AC 50Hz Voltage tolerance 10 Power supply output Voltag...

Page 4: ... LED ON 2 System Healthy LED ON 3 Zone 1 Alarm LED OFF 4 Zone 2 Alarm LED OFF 5 Zone 3 Alarm LED OFF 6 Zone 4 Alarm LED OFF Hooter with Flasher OFF 2 When digital input 1 is open Digital input 1 is opened LEDs 1 Mains ON LED ON 2 System Healthy LED OFF 3 Zone 1 AlarmLED ON 4 Zone 2 Alarm LED OFF 5 Zone 3 Alarm LED OFF 6 Zone 4 Alarm LED OFF Hooter with Flasher ON 3 When digital input 2 is open Dig...

Page 5: ...input 4 is opened LEDs 1 Mains ON LED ON 2 System Healthy LED OFF 3 Zone 1 Alarm LED OFF 4 Zone 2 Alarm LED OFF 5 Zone 3 Alarm LED OFF 6 Zone 4 Alarm LED ON Hooter with Flasher ON Silence Switch Silence switch can be used to silence the alarm triggered by GASMon If the user press silence switch in case of Gas detect then it will be considered as acknowledgement of alarm Relay Output The relay outp...

Page 6: ...tal Input 1 ve B PFC Output ON 1 Common Z1 GND C PFC Output ON 1 NC Z2 Digital Input 2 ve D PFC Output ON 2 NO Z2 GND E PFC Output ON 2 Common Z3 Digital Input 3 ve F PFC Output ON 2 NC Z3 GND Z4 Digital Input 4 ve G DC 12V Z4 GND H GND I Flasher Sounder ve J GND K NA L NA M NA N NA ...

Page 7: ... of loss during shipment Warranty does not include fuses disposable batteries or the routine replacement of parts due to normal wear and tear of the product Product warranty void if Any damage or defects attributable to repair of the product by any person other than an authorized dealer or the installation of unapproved parts on the product LCD LED crushed or bleeding Warpage to the main PCB as a ...

Page 8: ...f the products sold as per the invoice Manufacturer seller does not take any responsibility of any damages which arises because of timely non function of the product To and fro transportation cost till the centre factory at Pune to be borne by the customer For all warranty claims customer need to produce invoice warranty certificate ...