Operating Your Sentry System

1. Allow the Sentry System to operate at the pre-set level for at least 24 hours before adding cigars to your    

  cabinet. The initi al digital reading will be much lower than 70%, but will rise upon starti ng the system. 

2. The system will consume large quanti ti es of water during the seasoning stage of 3 to 4 days. Therefore, it is    

  important to keep the reservoir fi lled at all ti mes.

3. The Sentry Humidifi cati on System requires that you adjust the humidity level in response to the independent   

  LCD hygrometer. Close your cabinet’s door and allow the system to run for several hours. When the fan stops  

  running, the system has reached the set-point level and you should now note the humidity reading on the    

  hygrometer.

Adjusti ng the Set Point

4. With the knob at its lowest setti  ng, turn it slowly clockwise to increase the set point. Stop when the green 

          indicator turns on. The system is now set to the current Relati ve Humidity.

5. Turn the knob further in small increments to increase the Relati ve Humidity and wait. When the green  

 

  indicator automati cally turns off , the set point is at its current Relati ve Humidity on the display. If necessary,   

  adjust further unti l you reach your desired Relati ve Humidity. 

Note:

 Once set the system will not need adjustment and will maintain a Relati ve Humidity /- 5% of    

  your set point.

6. To lower your set point, slowly turn the control knob counterclockwise 1/8 turn and close the cabinet door.    

  You may have to repeat this process every few hours unti l you hit your desired humidity level. 

Note: 

If your system has been running at a high humidity level for an extended period of ti me it may take

  up to 10 days for the humidity level in your cabinet to drop to the new set point. 

The Sentry Humidifi cati on System electronically controls the humidity level of your Wall Humidor cabinet using 

a digital display. This system uses a manual dial to adjust the relati ve humidity within your cabinet and is accurate 

to +/-5% of your desired set point. 

Note: 

This is our standard system.

Summary of Contents for Sentinel 250

Page 1: ...idor Owner s Manual Sentinel 250 Wall Mounted Humidor _________________________________________________________________________________________ Vigilant Inc 85 Industrial Park Drive Dover NH 03820 888...

Page 2: ...ase read this entire manual before plugging in and operating your cigar cabinet By following these instruc tions you will not only ensure the proper operation of your Wall Humidor you will be guarante...

Page 3: ...VIGILANT WITHIN 7 DAYS OF DELIVERY OR THE DAMAGE CLAIM CANNOT BE HONORED To report any damage please contact us at 888 812 4427 2 Find a suitable location for your Wall Humidor away from temperature...

Page 4: ...1 Measure the cabinet and roughly locate where you would like to hang the cabinet before marking the wall 2 Measure up from the floor 69 and gently mark the wall with a pencil 3 Use the level to dete...

Page 5: ...mark the wall accordingly below the prior marked 69 line Note Vigilant recommends that at least one z clip be mounted at a stud location for maximum weight sup port and that both wall mounted z clips...

Page 6: ...vigilantinc com Page 6 6 Determine which of the two holes will land on the stud The one that is not landing on the stud will need to be drilled out to accept a supplied wall anchor 7 Using a drill bi...

Page 7: ...d secure one into the hole 9 Once secured locate the z clip and fasten to the wall using a 8 construction screw and supplied wall anchor screw We recommend hand tightening the wall anchor screw to ens...

Page 8: ...13 With the help of a second individual hold the humidor against the wall above where the clips will want to engage and let the humidor gently slide down the wall until the z clips attach together 14...

Page 9: ...ear of bacteria 4 Check to make sure that the white mesh wicking filters are positioned vertically in the slots in the reservoir They should protrude about an inch above the top edge of the reservoir...

Page 10: ...ther in small increments to increase the Relative Humidity and wait When the green indicator automatically turns off the set point is at its current Relative Humidity on the display If necessary adjus...

Page 11: ...se The final stabilization is required when the ambient parameter is near full scale Typically no longer than 30 minutes Operating Your Guardian System The Guardian Humidification System is our state...

Page 12: ...78 Low Alarm 62 LED Lighting The Wall Humidor comes with a dimming LED display lighting For convenience it comes with an easy to use touch control Maintenance Your Wall Humidor is more than just a ci...

Page 13: ...porarily surpass the factory set point of 68 Relative Humidity This may shut down active humidification for a short period until the humidity level falls back below the set point This is perfectly nor...

Page 14: ...fans and airflow intakes on each side of the reservoir are clear of any obstructions that can impede air circulation 4 Make sure humidity wicks are vertically positioned at least one inch above the re...

Page 15: ...lant electronic products are guaranteed to be free from defects in materials and or workmanship for up to two years from date of purchase Vigilant at its sole discretion may repair or replace defectiv...

Page 16: ...o any customer applied finishes or any damage caused by neglect abuse misuse improper operation or acts of God Vigilant s warranty is considered null and void if submittal of your warranty registratio...