Application Drawing 

Vi2308A

 

 8-Port UTP Ethernet Extender’s Installation Manual

DO NOT OPEN

RISK OF ELECTRIC SHOCK

CAUTION

CAUTION: 

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

                   DO NOT REMOVE COVER. NO USER SERVICEABLE

                   PARTS INSIDE. REFER SERVICING TO QUALIFIED

                   SERVICE PERSONNEL.

IP Camera-end Installation

The Smart Choice for Transmission Solutions                       

www.vigitron.com

The MaxiiCopper

TM

 Vi2308A is a revolutionary data transmission device that 

extends full-duplex High-Speed Ethernet over existing or new UTP 

infrastructures. It extends 10BaseT signals up to 3,000 ft. (909M) and 

100BaseT up to 2,100 ft. (640m). It employs MaxiiCopper, an innovative and 

unique Ethernet extension technology, that is designed to take full advan-

tage of high-bandwidth UTP cables and maintain a full-duplex 10 or 100 

Mb/s Ethernet connection up to the maximum range - with minimum 

transmission error and latency. Its dual-rate capability provides an easy way 

to balance the best possible network throughput and long-reach distance 

design. The Vi2308A 8 ports. 1 pair of UTP can be used for both 10BaseT 

and 100BaseT signals. 4 Pair is restricted to 100BaseT use.
The Vi2308A  needs to be deployed along with single port Vi23xxA on the 

remote end of each UTP cable. It is equipped with LEDs to provide link 

status and configured data rate for each port. It is completely transparent to 

the corporate IP network and higher layer protocols and requires no IP 

programming or other configurations. 
The Vi2308A is offered in 19 inch 1U height enclosure for rack-mount or 

wall-mount applications. It is an ideal for medium to large scale IT network-

ing or digital CCTV projects. 

Important Safety Warning

Ethernet Switch/NVR-end Installation

- Connect the chassis ground screw to a solid earth ground.

- Connect the RJ45 connector of the Ethernet switch to the 10/100BaseT 

  Ethernet port of Vi2308A using a standard Cat5/6 cable of maximum 100 m

   in length.

- Connect long UTP cables to the RJ45 connectors of the Vi2308A.

- Connect the 12V power supply to the power connector of the extender hub.
The link LED on the 10/100 Ethernet connectors should be “ON” to indicate 

proper connection between the switch and Ethernet ports of Vi2308A. While 

the Link LED, Orange for 100BaseT and Green for 10BaseT, on the 

extended side, in a steady state will indicate confirmed connection between 

extenders.       

- Read and keep these instructions.

- Heed all warnings.

- Follow all instructions.

- Do not use this apparatus near water.

- Clean only with a dry cloth.

- Install in accordance with the manufacturer’s instructions.

- This installation should be made by a qualified service person and should conform to all local 

codes.

- DO NOT bundle UTP or UTP signals in the same conduit as high-voltage wiring.

- To reduce the risk of fire or electrical shock, do not expose these products to rain, moisture, 

dripping or splashing.

- No objects filled with liquids, such as vases, shall be placed on Vigitron equipment.

- DO NOT install the unit in a place where the operating ambient temperature exceeds 75°C.

- Make sure that the external power supply output voltage is in the recommended range. 

- Do not install near any heat sources such as radiators, heat registers, stoves or other 

apparatus (including DVRs and NVRs) that produce heat.

- Protect the power cord from being walked on or pinched particularly at power source, 

convenience receptacles, and the point where they exit from the apparatus.

- Only use attachments/accessories specified by the manufacturer.

- Unplug this apparatus during lightning storms or when unused for long periods of time.

- Refer all servicing to qualified service personnel. Servicing is required when the apparatus 

has been damaged in any way, such as when a power supply cord or plug is damaged, liquid 

has been spilled, objects have fallen inside the apparatus, the apparatus has been exposed to 

rain or moisture, does not operate normally, or has been dropped.

- The main plug is used as the disconnect device and shall remain readily operable.

         WARNING! - To reduce the risk of fire or electric shock, do not expose 

this apparatus to rain or moisture. This apparatus shall not be exposed to 

dripping or splashing and no objects filled with liquids, such as vases shall 

be placed on the apparatus.
         WARNING! - This apparatus is a Class I product. This product must 

be connected to a mains socket outlet thru an AC to DC Power supply.
         WARNING! - The mains plug is used as the disconnect device and 

shall remain readily operable. 

- If you like to power the unit using a local power supply connect the 12VDC

  power supply to the power connector of the Vi2300A/Vi2301A. A power 

  adapter connector is provided to simplify connection.

- If no power supply is plugged in the unit will use PoE. When using PoE the

  camera has to be powered by PoE also.  

- Connect the IP camera RJ45 connector to the “10/100BaseT Ethernet” port 

  of Vi2300A/Vi2301A using a standard Cat5/6 cable of maximum 100 m in length.

- Connect one end of the long UTP cable to the “Extended Ethernet” RJ45

  connector of Vi2300A/Vi2301A .
The link LED on the 10/100 connector should be “ON” to indicate proper 

connection between the camera and Vi2300A/Vi2301A .

Max

ii

 

Copper

TM

Connecting Multiple PoE Cameras over Extended UTP

The Vi2308A and Vi230XXs can be used to connect multiple PoE cameras at extended distances.

Network Switch

Data + 

PoE

328 ft. (100m)

Data + 

PoE

328 ft. (100m)

Data + 

PoE

328 ft. (100m)

Data + 

PoE

328 ft. (100m)

PoE Cameras

Vi2301A

Vi2301A

Vi2300WP

Data + 

PoE

Extended Cat5/6

Data + 

PoE

Extended Cat5/6

Data + 

PoE

Extended Cat5/6

Data + 

PoE

Extended Cat5/6

Vi2300A

Vi2308A

Data + 

PoE

328 ft. (100m)