57
3-2.2 Rate Limiters
Parameter
Description
The section describes how to configure the switch’s ACL rate limiter parameters.
The rate limiter Level from 1 to 16 allows the user to set rate limiter value and units
with pps or kbps.
Web Interface
To configure ACL Rate Limiter in the web interface:
1.
Click Configuration, ACL, then Rate Limiter.
2.
Specify the “Rate” field and the range from 0 to 3276700.
3.
To scroll the unit with pps or kbps.
4.
Click “Apply” to save the setting.
5.
If you want to cancel the setting, click the reset button to revert back to
previously saved values.
Figure 3-2.2: The ACL Rate Limiter Configuration
Rate Limiter ID:
The rate limiter ID for the settings contained in the same row.
Rate:
The allowed values are: 0-3276700 in pps or 0, 100, 200, 300, .., 1000000 in
kbps.
Unit:
Specify the rate unit. The allowed values are:
Pps:
Packets per second.
Kbps:
Kbits per second.
Buttons
Apply
– Click “Apply” to apply changes.
Reset
- Click “Reset” to undo any changes made locally and revert back to
previously saved values.