background image

MODEL VG6046

9

B.    INSTALLING THE INNER DOOR PANEL

1.

Screw the double rollers (#8) to the inner
door panel (#7) using the allen key
supplied.  Once tightened, place the covers
on the rollers.

B1

4

2

8

8

7

INSIDE OF

THE SHOWER

7

8

COVERS

Summary of Contents for CASPIAN VG6046

Page 1: ...stallation of the product These instructions must be observed for safe installation Maintenance and other important non personal injury and non material damage instructions or statements that should be observed It is highly advised to dry fit the unit prior to any installation IMPORTANT SAFETY PRECAUTIONS WARNING 1 VIGO reserves the right to modify update all hardware and glass components based on...

Page 2: ...UALIFIED LICENSED PROFESSIONAL GLASS THICKNESS 3 8 PLEASE READ INSTRUCTIONS BEFORE PROCEEDING INSTALLATION INSTRUCTIONS FOR SHOWER DOOR 2 9 Door threshold cap 2pc 10 Phillips screw 3 4 4pc 11 Door threshold 1pc 12 Plastic anchors green 4pc 13 Bottom door guide 1pc 14 Single rollers 2pc 15 Outer door panel 1pc 16 8mm Screw cover 4pc 17 Door seal strip with flange 2pc 1 extra 18 Roller guides 2pc 4 ...

Page 3: ... COMPLETELY INSTALLED DIMENSION B OUTER DOOR DIMENSION A INNER DOOR HEIGHT MODEL DIMENSION C WIDTH 7 INNER DOOR PANEL 31 3 16 x 73 1 2 31 3 16 x 73 1 2 73 1 2 VG6046XX6074 59 61 14 SINGLE ROLLERS 98039 Product lines may change contact your Vigo representative at 1 866 591 7792 or visit our website at www vigoindustries com for the most up to date product line information 98128 96001 98125 98126 98...

Page 4: ...ems on your invoice with what you have received Carefully review the Parts List on page 2 If any items are missing please call Vigo Industries at 1 866 591 7792 Please check our website at www vigoindustries com for additional information or instructional videos IMPORTANT Fiberglass acrylic or sheetrock construction might not be sufficiently strong enough to support the shower door enclosure You s...

Page 5: ...1 MODEL VG6046 5 INSTALLATION STEPS NOTE Prior to any installation mark lines on the floor and wall for proper dry fit Proper planning is imperative for proper installation The measurements of 70 5 8 and 71 9 16 should just be used as a guide Your actual dimensions may vary This unit is design to fit a 60 61 opening without having to cut the rails but based off of specification needs the installer...

Page 6: ...opening Make sure that the wall mount brackets 2 are assembled on the rail before doing this Make sure the structural rail is level Mark the location of the wall mount brackets 2 on the wall Note If you have chosen to install this unit into a 59 opening you will have to cut the structural rail 4 in order for it to fit 71 9 16 The dimension supplied is measured at the center of the wall mount brack...

Page 7: ...he wall at the center of the holes of the plate Note It is important to perform a dry fit prior to install Once everything is level and plumb then you can begin your drilling A4 2 MARK THE TWO HOLES ON THE WALL WITH A PENCIL 2 A5 A6 1 1 6 Drill holes where you marked the walls and place plastic anchors 1 inside them Preferred method of installation negates anchors and has the installation going ri...

Page 8: ...right into the studs A7 PLATE 1 PLATE 1 3 8 Slide the bracket body 2 in position on the structural rail 4 Align the plates to the rail and slide the bracket body over the plate Lock the bracket body to the plate with the supplied allen key note the screws should be at the top of the rail Make sure the structural rail is level PLATE HEX SCREW ON TOP BRACKET BODY 4 PLATE 2 4 2 A8 ...

Page 9: ...6 9 B INSTALLING THE INNER DOOR PANEL 1 Screw the double rollers 8 to the inner door panel 7 using the allen key supplied Once tightened place the covers on the rollers B1 4 2 8 8 7 INSIDE OF THE SHOWER 7 8 COVERS ...

Page 10: ...10 MODEL VG6046 B2 4 2 7 2 Position the inner door panel 7 into the back of the structural rail 4 3 Find the center point of your shower opening and mark a line 8 B3 4 2 7 CENTER OF SHOWER OPENING ...

Page 11: ... door guide 13 5 Remove the inner door panel 7 Position the door threshold 11 into the bottom door guide 13 and place the bottom door guide to where you have marked Mark the hole locations for the bottom door guide 13 and door threshold 11 Note If you have chosen to install this unit into a 59 opening you will have to cut the door threshold 11 in order for it to fit 4 7 CENTER OF SHOWER OPENING 13...

Page 12: ...the green plastic anchors 12 inside them 7 Replace the door bottom guide 13 and door threshold 11 and screw them to the floor with 3 4 screws 10 8 Place the door threshold cap 9 over the end of the threshold and slide it towards the wall Repeat for the other side B7 12 13 13 10 12 10 B8 13 11 9 9 11 9 11 ...

Page 13: ...he structural rail 4 and bottom door guide 13 B8 4 7 13 C INSTALLING THE OUTER DOOR PANEL 1 Screw the single rollers 14 to the outer door panel 15 using the allen key supplied Once tightened place the covers on the rollers C1 INSIDE OF THE SHOWER 15 14 11 COVERS ...

Page 14: ...6 2 Place the two top rollers and the outer door panel 15 assembly onto the structural rail 4 3 Verify that the bottom of the door rests in the front notch of the bottom door guide 13 C2 C3 4 15 13 15 13 7 13 7 15 14 ...

Page 15: ...two bottom roller guides 18 to the door panel 15 using the allen key supplied C4 INSIDE HANDLE OUTSIDE HANDLE GLASS SUPPORT CLEAR WASHER CLEAR WASHER GLASS SUPPORT CLEAR WASHER CLEAR WASHER HEX SCREW HEX SCREW COVER 16 HEX SCREW HEX SCREW COVER 16 INSIDE OF THE SHOWER 15 18 SMALL HEX HOLE ...

Page 16: ...up using the heel of your hand to firmly press the seal strip onto the glass Note Make sure the flange on the door seal strip with flange 17 faces inside on the outer door panel 15 and outside on the inner door panel 7 to prevent any water leakage in between the doors 5 5 F APPLYING THE SILICONE 1 Apply clear silicone caulking along the threshold of the shower enclosure interior F1 11 11 17 ...

Page 17: ...to remove IMPORTANT 1 DO NOT use abrasive cleaners scrapers metal brushes or any items that could scratch or dull the surface 2 DO NOT allow surface to come in contact with acetone nail polish remover dry cleaning solution lacquer thinner gasoline or other similar products REGULAR CARE AND MAINTENANCE OF YOUR VIGO SHOWER ENCLOSURE Your home is a moving entity shifting and settling over time Vigo u...

Page 18: ...t as described in the installation guide so that VIGO can execute the warranty specified herein If such access is not available all expenses to provide said access will be the responsibility of the owner end user This warranty does not apply to Products that have not been installed or operated in accordance with instructions supplied by VIGO and all applicable rules regulations and legislation per...