background image

PRODUCT MANUAL

Designed, Manufactured and Supported in the USA

C O M M U N I C A T I O N   &   S E C U R I T Y   S O L U T I O N S

Add Keyless Entry and/or Card Reader Entry for a

Single Door with Up to 250 Users

Features

The 

ES-1

is a door controller designed to operate

a door strike or magnetic lock upon receiving a
valid card read and/or keyless entry code from Wie-
gand devices. One 

ES-1

, one or two Wiegand de-

vices and a door strike or magnetic lock of your
choice is required for each entry point.  

The Wiegand device used may be the 

Viking

model 

PRX-1

Proximity Card Reader and/or the

PRX-2

Proximity Card Reader with Keypad, 

PRX-

3

Medium Range Proximity Card Reader or or

PRX-4

Wiegand Output Keypad or any other card

reader, RF transmitter or digital keypad that outputs
the 26 bit Wiegand format. If two Wiegand devices
are used, one can be placed on each side of a
doorway to control access in both directions (entry
and exit). Up to 250 valid Wiegand codes can be
programmed into the 

ES-1

Other programmable parameters, like relay activa-
tion, mode (normal, off, or open) and facility codes

are also stored in non-volatile memory. All program-
ming is done with a local touch tone phone. Up to
three 

ES-1

s can be programmed simultaneously if

they will be sharing all the same programming
codes and parameters. Entry logging is possible
with the 

ES-1’

s log bus data output.

•  Up to 250 tenants

•  Program and control with a Touch Tone phone

•  Use with any 26 bit Wiegand device

•  Supports 1 entry point

•  Compatible with Viking models 

PRX-1

PRX-2

PRX-3

, and 

PRX-4 

and certain legacy 125KHz 

HID® proximity card readers*

•  Non-volatile memory (no batteries required)

•  LOG BUS data output for logging entry events

•  Card plus keypad mode for highest security

•  One time codes for visitors

•  Bi-directional (entry and exit) control

•  Business entrances

•  High rise apartment buildings

•  Condos

•  Senior citizen buildings

•  Assisted care centers

•  Retirement homes

•  Gated communities

Power:  

120V AC/12V DC 500mA, UL listed adapter pro-

vided or use any 12-24V AC or DC source @ 100mA (de-
signed to share power with the door strike’s power supply)

Dimensions:  

133mm x 89mm x 44mm (5.25” x 3.5” x

1.75”)

Shipping Weight:  

1.3 kg (3 lbs)

Environmental: 

0° C to 32° C (32° F to 90° F) with 5%

to 95% non-condensing humidity

Relay Contact Ratings:  

5A @ 30V DC/250V AC maxi-

mum

Maximum Wiegand Length:

152m (500 ft) - 24 AWG

Maximum LOG BUS Length:

1610m (5280 ft - 1 mile),

24 AWG

Connections:

11 screw terminals, (1) RJ-11 telco jack

ES-1

Stand Alone Door

Controller Entry System

July 3, 2014

Applications

Specifications

www.vikingelectronics.com

Information: (715) 386-8861

VIKING

* HID and the HID logo are registered trademarks of HID
Global Corporation, an ASSA ABLOY company. All other
trademarks are the property of their respective owners.

Summary of Contents for ES-1

Page 1: ...ogramming codes and parameters Entry logging is possible with the ES 1 s log bus data output Up to 250 tenants Program and control with a Touch Tone phone Use with any 26 bit Wiegand device Supports 1 entry point Compatible with Viking models PRX 1 PRX 2 PRX 3 and PRX 4 and certain legacy 125KHz HID proximity card readers Non volatile memory no batteries required LOG BUS data output for logging en...

Page 2: ...ns a 3 digit Facility Code a 5 digit Internal Card number and a 5 digit External Printed number that may or may not match the Internal number Proximity Card Reader A device used to read the data from a Proximity Card when its held within a few inches of the reader Note Maximum Wiegand run length is 600 feet using 24 gauge wire when using the Viking model PRX 1 proximity card reader 500 feet for th...

Page 3: ...16 STAND ALONE DOOR CONTROLLER ENTRY SYSTEM POWER 12V DC MODEL ES 1 1 POWER PROGRAM PHONE LOG BUS 2 3 4 5 GANG PROG 6 7 8 9 WIEGAND DEVICE 10 11 DOOR STRIKE N O 2 1 L H COM N C BLK RED GRN WHT VIKING VIKING ELECTRONICS HUDSON WI 54016 STAND ALONE DOOR CONTROLLER ENTRY SYSTEM POWER 12V DC MODEL ES 1 1 POWER PROGRAM PHONE LOG BUS 2 3 4 5 GANG PROG 6 7 8 9 WIEGAND DEVICE 10 11 DOOR STRIKE N O 2 1 L H...

Page 4: ...his will clear all entry codes all facility codes and set all programming to factory settings CAUTION All entry codes will be permanently erased The ES 1 can be set into one of 3 different operating modes The factory default setting is the NORMAL mode In the NORMAL mode the ES 1 strikes the door when a proper card or keyless code is entered Enter Q1 to put the ES 1 in NORMAL mode Enter Q0 to put t...

Page 5: ... activation time The ES 1 outputs event data on the LOG BUS each time a card or keypad is used An ID number can be pro grammed in each ES 1 so that the device receiving the LOG BUS data knows which entry point the event came from While in programming enter a single digit ID number 1 9 7 Example 6 7 an Entry Point ID number of 6 While programming the ES 1 a double beep will be heard after entering ...

Page 6: ...o gain ac cess If the card plus keypad mode is enabled first the card must match a programmed facility code and entry code then the same 5 digit entry code must be entered on the keypad for access to be granted In addition to using a Touch Tone phone to program the ES 1 a few Touch Tone commands are also available as follows An entry code can be programmed for one time use If this is the case once...

Page 7: ...Please use this chart to record the numbers programmed into the ES 1 USE PENCIL Security Code Relay Activation Code Memory Location Tenant s Name Entry Code 7 ...

Page 8: ...hat you will have to pay a restocking charge DOD 193 ZF301940 Rev B Due to the dynamic nature of the product design the information contained in this document is subject to change without notice Viking Electronics and its affiliates and or subsidiaries assume no responsibility for errors and omissions contained in this information Revisions of this document or new editions of it may be issued to i...

Reviews: