background image

F20334G EN

(111008J)

Viking Range Corporation

111 Front Street 

Greenwood, Mississippi 38930 USA

(662) 455-1200

For product information,

call 1-888-VIKING1 (845-4641)

or visit the Viking Web site at 

vikingrange.com

Viking Installation Guide

Built-In Gas Cooktops

Summary of Contents for DGCU105

Page 1: ...Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com Viking Installation Guide Built In Gas Cooktops ...

Page 2: ...m product This may void the warranty 3 Please observe all local and national codes and ordinances 4 Please ensure that this product is properly grounded 5 The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference Installation must conform with local codes or in the absence of codes the National Fuel Gas Code ANSI Z223 1 or ...

Page 3: ...e and other flammable vapors 5 Do not obstruct the flow of combustion and ventilation air 6 Disconnect the electrical supply to the appliance before servicing 7 When removing cooktop for cleaning and or service A Shut off gas at main supply B Disconnect AC power supply C Disconnect gas line to the inlet pipe D Lift appliance out of cabinet cutout 8 Electrical Requirement Normal grounded household ...

Page 4: ...OVERLAY INSTALLATION The bottom of the hood should be 30 76 2 cm min to 36 91 4 cm above the countertop This would typically result in the bottom of the hood being 66 167 6 cm to 72 182 9 cm above the floor Refer to the rangehood installation instructions for further information These dimensions provide for safe and efficient operation of the hood 30 76 2 cm min 36 91 4 cm max 30 76 2 cm min 36 91...

Page 5: ...3 36 min cutout VESO166 36 min cutout OPTIONAL INSTALLATION OF GASKET If desired the gasket can be installed to eliminate the space between the countertop and the cooktop This will help prevent spillovers into the cabinet underneath the cooktop 1 Remove the roll of gasket material from your packed with items 2 Turn your cooktop upside down on a flat surface Make sure to place some protective mater...

Page 6: ...2 5 cm 1 1 4 3 2 cm 5 3 8 13 7 cm 4 1 4 10 8 cm DGCU Height Dimension NOTE Minimum cutout height when using a 90 elbow supplied by installer 5 5 8 14 3 cm DGCU CUTOUT DIMENSIONS Cutout Opening B Min Max 30 W 28 3 4 73 0 cm 29 7 8 75 9 cm 36 W 34 1 2 87 6 cm 35 7 8 91 1 cm 45 W 42 7 8 108 9 cm 44 1 8 112 1 cm B 30 W Model 28 3 4 73 0 cm 36 W Model 34 1 2 87 6 cm 45 W Model 42 7 8 108 9 cm 19 11 16 ...

Page 7: ... 7 cm 1 3 4 4 5 cm 36 3 4 93 4 cm 12 Cutout Opening 19 3 4 50 2 cm Minimum 20 1 8 51 1 cm Maximum DGSU CUTOUT DIMENSIONS DGSU BURNER BOX DIMENSIONS Electric Cord 48 121 9 cm Gas Inlet 1 1 16 2 7 cm 1 1 16 2 7 cm 3 1 16 7 8 cm 30 W Model 29 1 8 74 0 cm 36 W Model 34 7 8 88 6 cm 19 3 4 50 2 cm C C Min Max 30 W 29 1 8 74 0 cm 29 7 8 75 9 cm 36 W 34 7 8 88 6 cm 35 7 8 91 1 cm ...

Page 8: ... to this intake pipe not supplied to the regulator supplied but not connected through the cooktop In Massachusetts This appliance must be installed with a 36 3 foot long flexible gas connector b Double check any installer supplied intake pipes visually and or blow them out with compressed air to clear any dirt particles threading chips or other foreign matter before installing in a service line Th...

Page 9: ...s turn the knob counter clockwise to any position 2 Upon ignition of the surface burner turn the knob to the desired position HI Med or Low 3 To shutdown the burner turn knob clockwise to the OFF position 4 In case of failure shut the gas OFF using the installer supplied manual shut off valve FINAL PREPARATION a New units are cleaned atthe factory to remove any visible signs of dirt oil grease etc...

Page 10: ...19 18 ...

Reviews: