Important - Read and Follow! 

Before beginning, please read these instructions completely and carefully.

•DO NOT remove permanently affi

  xed labels, warnings, or plates from product. This may void the warranty. 

• All local and national codes and ordinances must be observed. Installation must conform with local codes or in the absence of 

codes, the National Fuel Gas Code ANSI Z223.1 INFPA54.

•The installer must leave these instructions with the consumer who should retain for local inspector’s use and for future reference.

In Canada

: Installation must be in accordance with the current CAN/CGA B149.1 & 2 Gas Installation codes and/or local codes. 

Electrical installation must be in accordance with the current CSA C22.1 Canadian Electrical Codes
Part 1 and/or local codes.

In Massachusetts

: All gas products must be installed by a “Massachusetts” licensed plumber or gasfi tter. A “T” type handle manual 

valve must be installed in the gas supply line to the appliance.

An air curtain or other overhead range hood which operates by blowing a downward airfl ow onto the range, shall not be used 
with a gas range

To prevent possible damage to cabinets 
and cabinet fi nishes, use only materials and 
fi nishes that will not discolor or delaminate 
and will withstand temperatures up to 194°F 
(90°C). Heat resistant adhesive must be used 
if the product is to be installed in laminated 
cabinetry. Check with your builder or cabinet 
supplier to make sure that the materials meet 
these requirements.

WARNING

GAS LEAK HAZARD

To avoid risk of personal 
injury or death; leak testing 
of the appliance must be 
conducted according to the 

manufacturer’s instructions. Before 
placing appliance in operation, always 
check for gas leaks with soapy water 
solution.
•  DO NOT USE AN OPEN FLAME TO CHECK 

FOR GAS LEAKS

WARNING

WARNING

 ELECTRICAL SHOCK HAZARD

To avoid risk of electrical shock, 
personal injury or death; verify 
your appliance has been properly 

grounded in accordance with local codes or in 
absence of codes, with the National Electrical 
Code (NEC). ANSI/NFPA 70-latest edition

 TIPPING  HAZARD
To reduce the risk of 
the appliance tipping, 
it must be secured by 

a properly installed anti-tip bracket(s). To 
make sure the bracket has been installed 
properly, look behind the range with a 
fl ashlight to verify proper installation 
engaged in the rear top left corner of the 
range.

•  THIS RANGE CAN TIP
•  INJURIES TO PERSONS CAN RESULT
•   INSTALL ANTI-TIP DEVICE PACKED 

WITH RANGE

•  SEE INSTALLATION INSTRUCTIONS

WARNING

DANGER

CHEMICAL  HAZARD

To avoid risk of property 
damage and/or personal injury 
or death; this appliance is not 
too be used as a heating source.

Benzene is a chemical which is part of the 
gas supply to this cooking product, which is 
consumed in the fl ames during combustion. 
Exposure to a small amount of benzene is 
possible if a gas leak occurs. Formaldehyde 
and soot are by-products of incomplete 
combustion.

WARNING

 MOVING    HAZARD

To avoid risk of severe personal 
injury; this appliance requires two 
or more personnel while handling 

and moving. Possible use of appliance moving 
devices is recommended.

A GFI shall be used if required by NFPA-70 (National Electric Code), federal/state/local laws, or local ordinances.

• The required use of a GFI is normally related to the location of a receptacle with respect to any signifi cant sources of water or 

moisture.

• Viking Range, LLC will NOT warranty any problems resulting from GFI outlets which are not installed properly or do not meet the 

requirements below.

If the use of a GFI is required, it should be:

•Of the receptacle type (breaker type or portable type NOT recommended)
•Used with permanent wiring only (temporary or portable wiring NOT recommended)
•On a dedicated circuit (no other receptacles, switches or loads in the circuit)
•Connected to a standard breaker of appropriate size (GFI breaker of the same size NOT recommended)
•Rated for Class A (5 mA +/- 1 mA trip current) as per UL 943 standard
•In good condition and free from any loose-fi tting gaskets (if applicable in outdoor situations)
•Protected from moisture (water, steam, high humidity) as much as reasonably possible

Summary of Contents for VGIC5302

Page 1: ...1 Installation GUIDE Professional Freestanding Open Burner Gas Ranges VGIC5302 VGIC5362...

Page 2: ...w to reduce the chance of injury and tell you what can happen if the instructions are not followed Your safety and the safety of others is very important We have provided many important safety message...

Page 3: ...local codes or in absence of codes with the National Electrical Code NEC ANSI NFPA 70 latest edition TIPPING HAZARD To reduce the risk of the appliance tipping it must be secured by a properly instal...

Page 4: ...4 0 cm max 1 2 5 cm 29 7 8 75 9 cm 35 7 8 91 1 cm 25 3 4 65 4 cm 45 1 8 114 6 cm 19 3 8 49 2 cm 8 1 8 20 6 cm 26 7 16 67 2 cm 1 5 8 4 1 cm 1 2 5 cm 35 7 8 91 1 cm min to 37 94 0 cm max 24 5 16 61 8 cm...

Page 5: ...wire cord with grounded 3 prong plug attached to unit Maximum amp usage 83 amps 1 5 amps Surface Burners Natural LP 15 000 BTU 4 4 kW 13 500 BTU 4 3 kW Broil Burner Natural LP 18 000 BTU 5 3 kW 16 000...

Page 6: ...requirement does not apply if a range hood is installed over the cooking surface 46 min 116 8 cm 13 max 33 0 cm 8 min 20 3 cm 18 min 45 7 cm 3 8 0 95 cm 36 91 4 cm A opening width BURN HAZARD To avoid...

Page 7: ...trim Important Clearances from non combustible materials are not part of the ANSI Z21 1 scope and are not certified by CSA Clearances to non combustible materials must be approved by the authority ha...

Page 8: ...emand External regulators are not required on this range since a regulator is built into each unit at the factory Under no condition bypass this built in regulator Manifold pressure should be checked...

Page 9: ...r grates and styrofoam off the top cooking surface Be sure to remove the burner caps packaged in styrofoam below the burner grates Do not discard the anti tip metal brackets supplied with the range Th...

Page 10: ...mended that a pallet or lift jack be used rather than tilting Raise unit about a foot Unscrew temporary legs from couplings Screw legs into couplings on all four corners Lower range gently to keep any...

Page 11: ...nly as the adjustment required may exceed the thread available in the leg Move unit into opening Check that unit is level side to side and front to back Side trim of the high corner must be 3 8 0 95 c...

Page 12: ...evice must be engaged properly to prevent product from tipping over WARNING 1 Measurement A Measurement A Measurement A Measurement A Measurement A 1 4 64 cm 1 4 64 cm Measurement A 1 2 1 3 cm B 2 Mea...

Page 13: ...ance in operation always check for gas leaks This must be performed by your dealer a qualified licensed plumber or gas service company 1 1 8 1 8 32 cm 32 cm 1 8 32 cm 1 1 2 1 1 2 3 8 cm 3 8 cm 2 1 2 6...

Page 14: ...1 2 3 3 8 3 8 0 95 cm 0 95 cm 3 8 0 95 cm Slide range into place Be sure wall anti tip bracket slides into the anti tip opening or floor anti tip hook and bracket are engaged depending on the one used...

Page 15: ...ED SERVICE 111 Front Street Greenwood Mississippi 38930 Record the information indicated below You will need it if service is ever required You will first need to remove the left side surface burner g...

Page 16: ...Viking Range LLC 111 Front Street Greenwood Mississippi 38930 662 4551200 For more product information call 1 888 845 4641 or visit our website at www vikingrange com 069750 000 EN 060119...

Reviews: