3.  Peer to Peer Settings

When set to Peer to Peer mode, a SIP server is not used. The unit should be programmed with a Static IP Address and
Username, a password is not used. Caller ID can be programmed if needed. Simply call the unit by entering the pro-
grammed “username@192.168...(Static IP address for the unit)”. The static IP address is normally programmed into a
page button on the VoIP telephones. 

6.  Register Fails (Re-Resolve or Alternate Server)

4.  Outbound Proxy 

If your SIP provider requires an outbound proxy IP address enter it in the Outbnd Proxy field. If outbound proxy is not
required enter the SIP sever IP address into the Outbnd Proxy field.

NOTE: 

If not required, this field must match your

SIP server IP address.

5.  Authentication ID

If your SIP provider requires Authentication ID, enter it in the Authentic. ID field. If Authentication ID is not required,
leave this field blank.

2.  SIP Server

1.  Unit Name

Up to a 31 character unit name can be assigned to the 

1600-IP Series 

Phone being programmed. 

Programming Features

When registered to a SIP server in the event that registration is lost you can program the unit to re-resolve using the
current SIP server IP address or route pages through an alternate SIP server. With Alternate Server selected enter the
IP address of the alternate SIP server in the field next to the Register Fails drop down box.  

Note: 

With an alternate

SIP server IP address programmed, the IP address for the SIP server and alternate SIP server will be limited to 31
characters.

Enter the IP address or URL of your SIP server or service provider in this field. The SIP server IP address is limited to
74 characters.  

Note: 

If an alternate SIP server IP address is programmed, the IP address for the SIP server and

alternate SIP server will be limited to 31 characters. 

Note: 

If outbound proxy is not required, enter the SIP server IP

address into the Outbnd Proxy field.

Summary of Contents for 1600-IP Series

Page 1: ...95 non condensing Humidity EWP Products Up to 100 Audio Codecs G711u G711a G722 Network Compliance IEEE 802 3 af PoE SIP 2 0 RFC3261 100BASE TX with auto cross over Regulatory Compliance CE FCC Part 1...

Page 2: ...Express CUCME Elastix epygi QX200 Freeswitch Grandstream Interactive Intelligence iPECS Ericsson LG Iwatsu ECS Kamailio Mitel 3300 NEC OfficeSIP OpenSIPS Panasonic with SIP Extension Card PolyCom SIP...

Page 3: ...14 gauge marine grade 316 stain less steel with 4 brushed finish T 10 Torx Security Screws Model E 1600 22 IP HxWxD 5 0 x 5 0 x 2 25 Mounting Flush mount in a standard double gang electrical box or s...

Page 4: ...Protocol is an Internet protocol standard that specifies a way for programs to manage the real time transmission of multimedia data over either unicast or multicast network services Server A computer...

Page 5: ...itch optional Speaker Microphone MAC Address Label The MAC address is a unique 12 digit number used by routers to send network traffic to the correct IP address PoE LAN Port 10 100 PoE Class 1 4 Watts...

Page 6: ...aterial 062 16 gauge steel Finish E 1600 IP Red powder paint E 1600 45 IP Yellow powder paint E 1600 60 65 IP Blue powder paint Connections Gel filled butt connectors Mounting Surface mount to walls p...

Page 7: ...ting Flush mount in elevator cabs ATMs stairwells hallways etc Suggested Hardware 6 8 x 3 4 flat head phillips sheet metal type A screws not included Optional Enhanced Weather Protection EWP Available...

Page 8: ...aled per IP67 Dimensions 183mm x 149mm x 39mm 7 22 x 5 36 x 1 55 Material 14 gauge Marine grade 316 brushed stainless steel panel Shipping Weight 1 36 kg 3 lbs Connections Gel filled butt connectors M...

Page 9: ...faceplate and push button switches sealed per IP67 Laser Etched Graphics Note The black plastic rough in box part 259576 may be purchased separately Example Mounting boxes to studs before the walls a...

Page 10: ...nced Weather Protection EWP The optional EWP products feature foam rubber gaskets and boots sealed connections gel filled butt connectors as well as urethane or thermal plastic potted circuit boards S...

Page 11: ...th and or using a rough in box with inadequate depth can apply force to the circuit board causing physical damage Important When warm air comes in contact with cold surfaces such as outside walls and...

Page 12: ...t included Peel paper liner and adhere gasket to back of panel centering over mounting holes Caution For rough surfaces ie brick stucco etc additional caulking may be required Optional VE 5x5 Surface...

Page 13: ...15 0 19 EWP 3 50 3 58 EWP 3 20 2 0 2 04 EWP 0 63 0 67 EWP 1 5 2 63 2 71 EWP Mylar Speaker Dimensions Speaker Gasket EWP only Standard Mic Mounting Boot Glue or screw directly behind 0 04 0 125 diamete...

Page 14: ...R24 RL1 C58 R18 C17 R39 R50 R54 R65 R11 R32 R12 R34 R53 J3 J3 J3 J3 L9 C68 CR3 XTAL 2 TPG Z11 Z9 CR4 CR1 C C25 5 C37 7 c35 C5 L12 L11 L10 L8 R19 Z14 Z7 Z15 Z8 C59 R55 R58 L Z13 XTAL4 XTAL1 XTAL3 C55 5...

Page 15: ...nel Remove backing and adhere gasket to front panel of the E 1600 55 IP centering over speaker and microphone holes as shown Red LED anode Black LED cathode Note If you do not want to use the LED tuck...

Page 16: ...IP67 Push for Help Button Info Button available on model E 1600 TP2 IP EWP E 1600 TP IP EWP E 1600 TP2 IP EWP Dimensions 241mm x 299mm x 51mm 9 5 x 11 75 x 2 Shipping Weight 2 9 kg 6 4 lbs Mounting F...

Page 17: ...e and push button switch sealed per IP67 Push for Help Button E 1600 GT IP EWP Dimensions 254mm x 305mm x 51mm 10 0 x12 0 x2 Shipping Weight 2 9 kg 6 4 lbs Mounting Flush mount to GAI TRONICS towers w...

Page 18: ...enter E 1600 IP in the search box 2 Click E 1600 IP in the search results 3 Scroll down the page to Downloads click IP Programming Software 4 Install the programming software by saving or opening the...

Page 19: ...ing you to trouble shoot the failure A Connect Disconnect Open the Viking IP Programming software on the PC and the start screen shown below will appear Any Viking IP phones that are connected to the...

Page 20: ...ings tab Step 6 Select the appropriate value Static IP Settings or DHCP for Set Unit IP Address via Note changing the IP address will cause you to have to reconnect to the unit Enter the values for th...

Page 21: ...sconnecting the LAN Cable RJ45 plug Step 2 Press and hold the Call button then reconnect the LAN Cable RJ45 plug Step 3 Continue to hold Call button until you hear 2 beeps approximately 6 seconds Then...

Page 22: ...Microphone Volume 0 9 0 Auto factory set to 5 23 27 Talk Listen Delay VOX 0 1 0 9 seconds factory set to 0 5 seconds 24 27 In Band Audio Call Progress Enabled Disabled factory set to Enabled 25 27 In...

Page 23: ...is not required leave this field blank 2 SIP Server 1 Unit Name Up to a 31 character unit name can be assigned to the 1600 IP Series Phone being programmed Programming Features When registered to a S...

Page 24: ...ode Simply call the 1600 IP Series Phone set to auto answer auto answer secure the unit will automatically answer the line and output one beep You then enter the programmed 1 6 digit access code 2 bee...

Page 25: ...ll to or from the Emergency Entry phone This mode is useful for turning on IR flood lights VoIP phones with cameras etc Doorbell Mode When programmed for Doorbell Mode the relay will momentarily activ...

Page 26: ...nly Pressing the button again after the call has been initiated will not terminate the call Factory Setting Enabled 19 Alternating Switch Action Panic Button Mode When set to Ring or Ring with AGC The...

Page 27: ...Ring No Answer limit or touch tone to hang up Factory Setting 3 minutes 29 Call Length Timeout This feature selects switching time between talk and listen modes VOX switching time The Talk Listen Del...

Page 28: ...e secure options for auto answer require the callers to dial the access code in order to transmit a page activate the relay or activate the optional RC 4A relays Factory Setting Auto Answer Disabled I...

Page 29: ...erent modes Factory Setting Entry Phone OFF Mode Useful for silent monitoring applications In this mode the LED will not light during normal operation It will only light blink if it cannot register wi...

Page 30: ...39 IP Firmware If new 1600 IP Series Phone firmware is available after opening the programming software a pop window will come up asking you if you would like to update firmware An alternative method...

Page 31: ...know the location of the emergency call by either the voice announcement or by decoding the touch tone I D number Once the Call Connected LED is on the key can be used to force the phone to hang up B...

Page 32: ...post single gang box or a VE GNP gooseneck pedestal Note The VE 3x5 is not compatible with the VE GNP pedestals and is not available in stainless steel The VE 3x5 is designed to be used with the E 40...

Page 33: ...voltage automatic battery disconnect to prevent deep cycling battery mounting hardware and 4 optional Chevron arrows with mounting templates included ARS TB100 6 wide x 9 tall Tactile Sign with 0 031...

Page 34: ...in the workmanship or materials under normal use and service for a period of two years from the date of purchase from any authorized Viking distributor If at any time during the warranty period the pr...