26
When set to “Enabled” the Remote Access Operation Commands (
0 to
1) to Un-Latch or Latch the relay are enabled.
These can be entered on a Inbound call after the access code is dialed (if programmed).
When set to “Disabled” the Remote Access Operation Commands (
0 to
1) to Un-Latch or Latch the relay are
disabled. Disabling the Latch commands can be useful in applications where you want to eliminate the possibility of
inadvertently entering a latch command leaving a gate open/closed, etc.
Factory Setting:
Enabled
18. Relay Latch Commands
The Speaker volume can be set from 0 - 9, 0 = lowest volume setting, 9= highest volume setting. Adjusting this will set
the volume level for incoming/outgoing Phone calls.
Factory Setting:
3
21. Speaker Volume
20. Speaker Mode
The Speaker Mode can be set to one of the following three modes.
Factory Setting:
ON
OFF/Silent Monitoring Mode:
In the “OFF” mode the speaker is disabled at all times. However, the speaker can be
enabled after communication has been established by entering touch tone command “
9#
”. The speaker will remain on for
the duration of the call.
ON (factory setting):
In the “ON” mode the speaker is enabled during In-bound and Out-bound calls.
OFF Until Answered:
In the “OFF Until Answered” mode the speaker will remain silent during dialing and will not turn
on until the called party has answered
.
With Alternate Switch Action Enabled the CALL button alternately connects and disconnects calls. With Alternate Switch
Action Disabled the CALL button connects calls only. Pressing the button again after the call has been initiated will not
terminate the call.
Factory Setting:
Enabled
19. Alternating Switch Action (Panic Button Mode)
When set to Ring or Ring with AGC, The
1600-IP Series Phone
will output a loud ring when it is called. The level can
be adjusted from 0 - 9.
Factory Setting:
5
22. Ring Volume
The relay activation tone is a buzzing sound that is heard from the speaker when the door strike relay is activated.
After the called party enters the correct relay activation command, the called party will hear 2 short confirmation beeps
and the entry phone will output a buzzing sound (relay activation tone) while the door strike relay is activated. The tone
(buzz) length will match the relay activation time up to a maximum of 5 seconds. The tone (buzz) can be programmed
to three different volume settings 1 = Low, 2 = Medium, 3 = High or it can be disabled.
Factory Setting:
3
17. Relay Buzz Volume
The one or two digit code stored in the Relay Activation Command is the touch tone command that the person being
called must enter on their phone in order to momentarily activate the relay to control a doorstrike, mag-lock, gate
controller, or other device. The code can contain the characters 0 - 9, # or
. The code cannot match a relay latching
command (
1,
0). The code must be entered while the remote phone is communicating with the Speaker phone.
Factory Setting:
15. Relay Activation Command
The value stored in the Relay Activation Time is the amount of time the relay will be energized after a correct momentary
touch tone command is entered. This number can range from 0.5 - 99 seconds. This also affects timing in Doorbell
Mode.
Factory Setting:
5 seconds
16. Relay Activation Time