10
ALARM RESET
Power Failure
ALARM RESET
Temp
NOTE
Door Ajar
Temp
Door Ajar
ALARM RESET
This alarm condition can be reset by closing the door or
momentarily pressing the "On/Off" keypad, (i.e.-if you
are cleaning the storage compartment, etc.). The alarm
will recur in 5-minutes if the alarm condition persists.
USING YOUR ELECTRONIC CONTROL
•
Power failure -
If power to the appliance is inter-
rupted the System Status indicator will turn-off and
the "Power Failure" indicator will fl ash. Additionally, an
"ALARM RESET" indicator will be displayed below the
"On/Off" keypad. No audible tone will sound. This alarm
condition can be reset by momentarily pressing the
"On/Off" keypad. If this alarm occurs, it is recommend-
ed that you check the condition of any perishables,
even if the appliance is operating normally and the tem-
perature has recovered, as prolonged power outages
could result in excessive temperature excursions which
may spoil perishables.
•
Temperature alarm -
If the storage compart-
ment temperature deviates excessively from your
set-point temperature for an extended period of time,
the "TEMP" indicator will fl ash, and an audible tone
will sound every 60 seconds. Additionally, an "ALARM
RESET" indicator will be displayed below the "ON/
OFF" keypad.
Multiple alarms are possible, i.e.- "Door Ajar" for a pro-
longed period may trigger a "Temp" alarm, in which case
both "Door Ajar" and "Temp" indicators will activate.
•
Door ajar -
If the door is open, or not closed prop-
erly, for more than 5-minutes the System Status OK
indicator will turn-off, the "Door Ajar" indicator will fl ash,
and a tone will sound every 60 seconds. Additionally,
an "ALARM RESET" indicator will be displayed below
the "On/Off" keypad.
Alarms:
The control will alert you to conditions that could adversely
affect the performance of the appliance.
This alarm condition can be reset by momentarily pressing
the "On/Off" keypad. If this alarm occurs it is recommended
that you check the condition of your stored contents, even
though the appliance is operating normally and the temper-
ature has recovered, as prolonged temperature excursions
could spoil perishables.
NOTE
The audible alarm can be muted, for each occurrence, by
pressing the lock keypad.
NOTE
The audible alarm can be muted, for each occurrence,
by pressing the lock keypad.
NOTE
NOTE
After a high temperature alarm condition, check all perish-
ables to ensure they are safe for consumption.
The temperature alarm may occur as a result of high usage
or introduction of warm contents to the storage compart-
ment. If the temperature alarm continues to occur, your unit