background image

The 

C-250

allows single line telephones or a

telephone system to share a phone line with a
single Viking entry phone.  Tenants may answer
an entry phone call, converse with the visitor
and let them in with a touch tone command.

The 

C-250 

also has a built in five number dialer

to make an outside call if there is no answer on
the inside phone. If the outside call is busy or
ring no answer, the 

C-250

can call up to four

more numbers.

The 

C-250

provides a “Call Waiting” tone when the phone line is in use. Tenants may

also call out to the entry phone for monitoring purposes. 

Single Entry Phone Controller with Call

Forwarding and Door Strike Control

P

P

r

r

a

a

c

c

t

t

i

i

c

c

e

e

T

T

E

E

L

L

E

E

C

C

O

O

M

M

S

S

O

O

L

L

U

U

T

T

I

I

O

O

N

N

S

S

F

F

O

O

R

R

T

T

H

H

E

E

2

2

1

1

S

S

T

T

C

C

E

E

N

N

T

T

U

U

R

R

Y

Y

TECHNICAL

TECHNICAL

C-250

C-250

Entry Phone Controller 

with Call Forwarding

May 18, 2012

•  Allows single line telephones or a telephone system 

to share a phone line with a Viking entry phone

•  Double burst ring pattern allows you to distinguish 

entry phone calls from CO calls

•  Built in five number dialer

•  Detects busy or ring no answer and goes onto the 

next number

•  Built in door strike relay with 1 or 2 digit commands

•  Remote programming

•  Auto answer

•  Detects touch tones as fast as 50 milliseconds

•  Trigger input for postal lock, Request to Exit (REX)

or immediate call forwarding

•  Produces “Call Waiting” tones if the entry phone

is activated when the house phones are already
on a call

•  Compatible with any Viking 

E

Series or 

K

Series 

entry phone or use with any standard analog phone

F

F

e

e

a

a

t

t

u

u

r

r

e

e

s

s

P

P

h

h

o

o

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

8

8

8

8

6

6

1

1

h

h

t

t

t

t

p

p

:

:

/

/

/

/

w

w

w

w

w

w

.

.

v

v

i

i

k

k

i

i

n

n

g

g

e

e

l

l

e

e

c

c

t

t

r

r

o

o

n

n

i

i

c

c

s

s

.

.

c

c

o

o

m

m

Power: 

120VAC / 13.8VAC 1.25A, UL listed adapter provided

Dimensions: 

133mm x 104mm x 44mm (5.25" x 4.1" x 1.75")

Shipping weight: 

0.9kg (2 lbs.)

Environmental:  

0°C to 32°C (32°F to 90°F) with 5% to 95%

non-condensing humidity

Ring Output: 

5 REN, capable of ringing (10) 0.5 REN phones

Talk Battery:

32V DC

Relay Contact Rating:

5A @ 30VDC / 250VAC Maximum

Connections: 

(12) cage clamp screw terminals

S

S

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

•  Add an entry phone to your standard home or 

office phones to provide door communication

•  Provide commercial or residential security via 

two-way handsfree communication at the door 
or gate

•  Connects in series with a single phone line or 

with a phone system’s line/trunk input

A

A

p

p

p

p

l

l

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

Summary of Contents for C--250

Page 1: ...to the next number Built in door strike relay with 1 or 2 digit commands Remote programming Auto answer Detects touch tones as fast as 50 milliseconds Trigger input for postal lock Request to Exit REX...

Page 2: ...trikes and other electrical surges PART 15 LIMITATIONS This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits...

Page 3: ...nt to wait 20 seconds just enter 7 and the programming mode will be terminated immediately 3 C Using the C 250 with a Proximity Card Reader or a Separate Keyless Entry Keypad Step 1 Program the ES 1 R...

Page 4: ...Ignore touch tones for programming entry phone To reset all programming to factory default settings Exit programming The following commands are used during normal operation Enable Immediate Call Forw...

Page 5: ...onnected to the door phone The C 250 determines which direction the touch tone is coming from and only responds to touch tones from the called phone Because of this single digit codes must be a minimu...

Page 6: ...to the phone line if there is no answer at the house phone To enable this mode enter Q1 when in programming To cancel the No CO mode enter Q0 M Door Bell mode Q2 Q3 If the door strike relay is not be...

Page 7: ...bled each time the house phone goes off hook a single beep will be heard in order to let the user know that this mode is on To cancel the Immediate Call Forward mode pick up the house phone and enter...

Page 8: ...rough another Door Strike timing cycle If DIP Switch 2 is in the ON position the Trigger Switch input now controls whether or not the house phone will ring when the entry phone goes off hook If the Tr...

Reviews: