background image

Model CTG-1 (DOD# 460) with CTGF-BKD Software

PM

TIME

/ CANCEL

-

+

MODE

ALERT TONES

SINGLE

DOUBLE

TRIPLE

VIKING

©

MODEL CTG-1

LOCK

SET DAY

SET TIME

SET EVENTS

REVIEW/CANCEL

CLOCK CONTROLLED

TONE GENERATOR

VOL

9V BATTERY

BACKUP

1 2 3 4 5 6 7 8 9 10 11 12

LED1

S1

C

LED3 LED2

C C

1

3

2

ON

VIKING

©

VIKING

ELECTRONICS

HUDSON, WI 54016

ENTRY CONTROLLER

WITH CALL FORWARD

POWER 13.8V AC

MODEL C-250

AUT

ANSWER

1

EARTH GND

1

TRIGGER MODE

2

LEARN MODE

3

POWER

CALLING

LINE IN

2

3

PHONES

4

5

ENTR

Y

6

7

TRIGGER

INPUT

8

9 10 11 12

DOOR

STRIKE  

N.C. 

N.O. 

COM

P

P

r

r

o

o

g

g

r

r

a

a

m

m

m

m

i

i

n

n

g

g

A. Accessing the Programming Mode

The 

C-250

can be programmed from any touch tone phone connected to the house phone port or by calling into the

unit from a remote touch tone phone. A 6-digit security code is used to gain access, or set DIP switch 3 to the ON posi-
tion for immediate access. If a command is entered correctly, 2 beeps will be heard, 3 beeps signal an error.

Once in the remote programming mode if no commands are entered for 20 seconds, you will hear 3 beeps and the pro-
gramming mode will be terminated. If you do not want to wait 20 seconds, just enter “##7” and the programming mode
will be terminated immediately.

3

C. Using the C-250 with a Proximity Card Reader or a Separate Keyless Entry Keypad

Step 1.

Program the 

ES-1

“Relay Activation Time” to match the “Doorstrike Activation Time” on the 

C-250

.

Step 2.

Connect the 

ES-1

relay output in parallel with the doorstrike output contacts on the 

C-250

.

STAND-ALONE

DOOR CONTROLLER

ENTRY SYSTEM

VIKING

PROGRAM

PHONE

GANG
PROG

COMM

ELECTRONICS

HUDSON, WI 54016

VIKING

©

MODEL ES-1

POWER 12 VDC

BLK

RED

GRN

WHT

ENTRY POINT

WIEGAND

DEVICE

LOG
BUS

Viking PROX-1 Proximity Card Reader

(shown, not included, DOD# 221)

OR

Viking HID-2 Keypad

(not included, DOD# 199)

and/or

(Power typically not

required for gate controllers)

Doorstrike/

Magnetic Lock

5A@30VDC/
250VAC
maximum

Viking E-70 Entry Phone

(shown, not included, DOD# 207)

OR

Viking E-75 Entry Phone

(not included, DOD# 208)

LED1

S1

C

LED3 LED2

C C

1

3

2

ON

VIKING

©

VIKING

ELECTRONICS

HUDSON, WI 54016

ENTRY CONTROLLER

WITH CALL FORWARD

POWER 13.8V AC

MODEL C-250

AUT

O ANSWER

1

EARTH GND

1

TRIGGER MODE

2

LEARN MODE

3

POWER

CALLING

LINE IN

2

3

PHONES

4

5

ENTR

Y

6

7

TRIGGER

INPUT

8

9 10 11 12

DOOR

STRIKE  

N.C. 

N.O. 

COM

B.  Using the C-250 with the CTG-1 or a Toggle Switch for Immediate Call Forwarding

Certain Hours of the Day

Note: 

DIP Switch 2 must be ON.

Summary of Contents for C--250

Page 1: ...to the next number Built in door strike relay with 1 or 2 digit commands Remote programming Auto answer Detects touch tones as fast as 50 milliseconds Trigger input for postal lock Request to Exit REX...

Page 2: ...trikes and other electrical surges PART 15 LIMITATIONS This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits...

Page 3: ...nt to wait 20 seconds just enter 7 and the programming mode will be terminated immediately 3 C Using the C 250 with a Proximity Card Reader or a Separate Keyless Entry Keypad Step 1 Program the ES 1 R...

Page 4: ...Ignore touch tones for programming entry phone To reset all programming to factory default settings Exit programming The following commands are used during normal operation Enable Immediate Call Forw...

Page 5: ...onnected to the door phone The C 250 determines which direction the touch tone is coming from and only responds to touch tones from the called phone Because of this single digit codes must be a minimu...

Page 6: ...to the phone line if there is no answer at the house phone To enable this mode enter Q1 when in programming To cancel the No CO mode enter Q0 M Door Bell mode Q2 Q3 If the door strike relay is not be...

Page 7: ...bled each time the house phone goes off hook a single beep will be heard in order to let the user know that this mode is on To cancel the Immediate Call Forward mode pick up the house phone and enter...

Page 8: ...rough another Door Strike timing cycle If DIP Switch 2 is in the ON position the Trigger Switch input now controls whether or not the house phone will ring when the entry phone goes off hook If the Tr...

Reviews: