background image

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or subsidiaries assume no respon-
sibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate such changes.

DOD# 172

ZF302800 Rev B

Printed in the U.S.A.

P

P

r

r

o

o

d

d

u

u

c

c

t

t

S

S

u

u

p

p

p

p

o

o

r

r

t

t

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

8

8

6

6

6

6

6

6

F

F

a

a

x

x

B

B

a

a

c

c

k

k

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

4

4

3

3

4

4

5

5

8

C

C

o

o

m

m

p

p

a

a

t

t

i

i

b

b

l

l

e

e

P

P

r

r

o

o

d

d

u

u

c

c

t

t

s

s

Single Gang and Double Gang Entry Phones Available in 5 Attractive Finishes

E-40-SS

“Brushed Stainless Steel”

(similar to brushed nickel)

Compact single gang entry phone.
See 

DOD# 187

.

E-60-PB

“Polished Brass”

(with clear gloss powder paint to 
prevent tarnishing)

Double gang entry phone. 
See 

DOD# 206

.

E-65-WH

“Satin White”

(satin white powder paint)

Double gang entry phone with built-in 
color video camera. See 

DOD# 203

.

E-75-SS

“Brushed Stainless Steel”

(similar to brushed nickel)

Double gang entry phone with built-in 
proximity card reader and color video 
camera. See 

DOD# 208

.

E-70-BK

“Satin Black”

(fine texture satin black powder paint)

Double gang entry phone with built-in 
proximity card reader. See 

DOD# 207

.

The 

C-250

has a Trigger Input for an external Postal Lock switch, or a Request to Exit (REX) switch. The switch must

have a momentary, normally open contact. Once the 

C-250

detects a contact closure on terminal positions 8 and 9, the

door strike will be energized for the amount of programmed Door Strike Activation Time. If the contact is still made after
the programmed time is up, the 

C-250

will re-energize the door strike relay and go through another Door Strike timing

cycle. 

If DIP Switch 2 is in the ON position, the Trigger Switch input now controls whether or not the house phone will ring
when the entry phone goes off hook. If the Trigger Input is shorted, the house phone ringing will be skipped (Immediate
Call Forward Mode), if open, the 

C-250

will ring the house phone when the entry phone goes off hook. The touch tone

command 

QQQ

overrides the status of the Trigger Input when DIP Switch 2 is ON.

D. Activating the Door Strike Relay

Anytime the house phone is connected to the entry phone, the tenant can actuate the door strike by entering the door
strike command on their touch tone keypad. The 

C-250

determines if the touch tones are coming from the house phone

or the entry phone and only accepts commands from the house phone. Once a valid command is detected, the door
strike relay will actuate for the amount of programmed Door Strike Activation time. If an invalid command is entered,
wait a few seconds and try again. The 

C-250

will wait 3 seconds after any touch tone entered to assure no more tones

are coming, then it looks for a command match. The 

C-250

can be programmed to handle either a 1 digit or 2 digit Door

Strike Command (position #41). If a single digit is being used, the minimum touch tone length is 100 milliseconds.
During this time the 

C-250

must determine if the touch tone is coming from the entry phone or the called party. If the

C-250

is having trouble detecting touch tones from a remote phone because the tones are too fast, use a 2 digit door

strike command. When using 2 digits, the touch tones can be as fast as 50 milliseconds, but the entry phone will be
dropped after the first digit is detected. The 

C-250

can then be sure that the touch tones are coming from the called

phone.

E. Trigger Input

E-50-BN

“Oil Rubbed Bronze”

(satin dark brown powder paint 
with fine copper metallic)

Compact single gang entry phone with 
built-in color video camera. See 

DOD# 191

.

Summary of Contents for C--250

Page 1: ...to the next number Built in door strike relay with 1 or 2 digit commands Remote programming Auto answer Detects touch tones as fast as 50 milliseconds Trigger input for postal lock Request to Exit REX...

Page 2: ...trikes and other electrical surges PART 15 LIMITATIONS This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits...

Page 3: ...nt to wait 20 seconds just enter 7 and the programming mode will be terminated immediately 3 C Using the C 250 with a Proximity Card Reader or a Separate Keyless Entry Keypad Step 1 Program the ES 1 R...

Page 4: ...Ignore touch tones for programming entry phone To reset all programming to factory default settings Exit programming The following commands are used during normal operation Enable Immediate Call Forw...

Page 5: ...onnected to the door phone The C 250 determines which direction the touch tone is coming from and only responds to touch tones from the called phone Because of this single digit codes must be a minimu...

Page 6: ...to the phone line if there is no answer at the house phone To enable this mode enter Q1 when in programming To cancel the No CO mode enter Q0 M Door Bell mode Q2 Q3 If the door strike relay is not be...

Page 7: ...bled each time the house phone goes off hook a single beep will be heard in order to let the user know that this mode is on To cancel the Immediate Call Forward mode pick up the house phone and enter...

Page 8: ...rough another Door Strike timing cycle If DIP Switch 2 is in the ON position the Trigger Switch input now controls whether or not the house phone will ring when the entry phone goes off hook If the Tr...

Reviews: