© 2010 Viking Preferred Service
32
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.
Service Diagnostics and Procedures–Disassembly
Water Filter
The unit has a water filter system designed to filter
a flow rate of 0.78GPM and a maximum pressure of
120 PSI.
To access the water filter:
1.
Locate water filter. Press release button to
release filter and pull filter out.
2.
Turn water filter cap clockwise to remove from
water filter.
3. Reverse procedure to reinstall.
Upper Refrigerator Light Bulbs
The unit uses standard 40W, 120VAC light bulbs to
illuminate the upper refrigerator compartment.
To access the upper light bulbs:
1.
Open refrigerator door and press in button to
release light cover.
2. Slide cover to rear wall to remove cover.
4. Remove/replace light bulb.
5. Reverse procedure to reinstall.
Button
Water Filter Cap