© 2010 Viking Preferred Service
42
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power to unit using power
switch before servicing. Wires removed during disassembly must be replaced on proper terminals to insure
correct earth ground and polarization. After servicing, reconnect power using power switch.
Service Diagnostics and Procedures–Disassembly
Emitter Board
1. Open ice maker door.
2. Remove phillips screws.
3.
Lower door into freezer compartment
and disconnect wiring.
4. Remove phillips screws to remove board.
5. Reverse procedure to reinstall.
Upper Freezer Light Bulb
The unit uses a standard 40W, 120VAC light bulb to
illuminate the upper freezer compartment.
To access the upper light bulb:
1.
Remove Ice maker,
(see ice maker section,
page
39)
.
2. Press tabs and remove bulb cover.
4. Remove/replace light bulb.
5. Reverse procedure to reinstall.
Screw
Wiring
Screw
Tabs