Temperature Offset Calibration
Offset amounts adjusts temperatures for unit cut-ins and
cut-outs by the amount of offset. The chart shows the
indicator and the amount of offset from the factory default
setting.
•
Setting Refrigerator Temperature Offset (All
Refrigerator Only).
Press Ref Temp pad. Refrigerator temperature
indicator and one indicator will glow. Press Higher
pad to move offset to the next warmer setting.
Press Lower pad to move offset to the next colder
setting. Factory default setting is 3. The freezer
thermistor circuit is simulated. The freezer
temperature offset is factory set to 9 and MUST
NOT be changed.
•
Setting Freezer Temperature Offset (All Freezer
Only.
Press FRZ Temp pad. Freezer temperature indicator and one indicator will glow.
Press Higher pad to move offset to the next warmer setting. Press Lower pad to
move offset to the next colder setting. Factory default setting for the 36” W. All
Freezer is 5 and the 30” W. All Freezer is 6.
Defrost Mode Selection
Toggle Hidden Button pad to select adaptive or conventional defrost mode. Hidden
Button indicator glows when adaptive defrost has bee selected. If Hidden Button
indicator is off, conventional defrost is selected. Conventional defrost uses 8 hour CRTD
value (4,8,8…hours). The CRTD can be changed in Program Mode A.
Forced Defrost (All Freezer Only)
Defrost can be forced to start by pressing and holding the Alarm Off pad for 3 seconds.
Program changes will be saved permanently in EEPROM and program mode will exit to
Run Mode A.
Forced Pull Down
Compressor start can be forced by pressing and holding the Alarm Off pad for 3 seconds.
Program changes will be saved permanently in EEPROM. Compressor, evaporator fan
and condenser fan will come on
. Note: For All Refrigerators, there is two (2) minute
dwell time after the unit has been turned off. A forced pull down will NOT initiate until
after the dwell time has been met and the unit is powered on.
Exiting Program Mode
Press Activate Controls pad for 3 seconds to exit Program Mode. Tone will sound three
times. Changes made in Program Mode will be permanently saved in EEPROM.
Note: If
no pad is pressed for 10 minutes, Program Mode will be automatically exited. However,
no changes will be saved if Program Mode exits automatically.
Summary of Contents for Designer DDFB304
Page 1: ...F90612...
Page 2: ...F90612 VIKING RANGE CORPORATION P O DRAWER 956 GREENWOOD MS 38930 USA...
Page 22: ...21 Wiring Schematic 30 W All Freezer...
Page 23: ...22 AF 30 LIGHT CIRCUITS...
Page 24: ...23 AF 30 120V CIRCUIT...
Page 25: ...24 AF 30 SEALED SYSTEM...
Page 26: ...25 AF 30 ICEMAKER CIRCUIT...
Page 27: ...26 Wiring Schematic 36 W All Freezer...
Page 28: ...27 AF 36 LIGHT CIRCUITS...
Page 29: ...28 AF 36 120V CIRCUIT...
Page 30: ...29 AF 36 SEALED SYSTEM...
Page 31: ...30 AF 36 ICEMAKER CIRCUIT...
Page 32: ...31 Wiring Schematic 30 W All Refrigerator...
Page 33: ...32 AR 30 120V INPUT AR 30 LIGHT CIRCUITS...
Page 34: ...33 AR 30 SEALED SYSTEM...
Page 35: ...34 Wiring Schematic 36 W All Refrigerator...
Page 36: ...35 AR 36 120V INPUT AR 36 LIGHT CIRCUITS...
Page 37: ...36 AR 36 SEALED SYSTEM...
Page 39: ...38 ALL MODELS New Control Boards with adapter functionality...
Page 40: ...39...
Page 48: ...47 SEALED SYSTEM...