4.
Individual upper oven tests (DDOE305T – cont.)
Individual oven tests (DSOE305T – cont.)
Step To test:
Test
Result
To exit:
17
Press SET
Door Lock State
Position of door lock switch
Enter, Clear, or
Down arrow
18
Press SET
Door Unlock
Engage door lock to unlock door
Enter, Clear, or
Down arrow
19
Press SET
Door Lock State
Position of door lock
switch
Enter, Clear, or
Down arrow
To exit this test, select the “ENTER”, “CLEAR”, or “DOWN ARROW” pad.
5. Individual lower oven tests (DSOE305T)
This test allows the individual to scroll to a specific component and then select it for testing. To enter this
test, enter diagnostic mode
(see accessing the diagnostic section, page 18)
. With the unit in diagnostic
mode, press the “DOWN ARROW” pad to scroll to the Individual lower oven test and press the “ENTER”
Pad. When you have selected this test, the first screen you will see will be the one shown below.
The following is a table consisting of all the individual components that can be tested in this program.
To scroll through each test, use the “UP ARROW” or “DOWN ARROW” pad, and then press “SET” or
“ENTER” to run the selected component test.
Step To test:
Test
Result
To exit:
1
Press SET
Inner Bake Element
SKIP THIS TEST
(No amperage should be read on
Step 1. Not used on DSOE and
DDOE models )
Enter, Clear, or
Down arrow
2
Press SET
Outer Bake Element
Run bake element***
Enter, Clear, or
Down arrow
3
Press SET
Inner Broil Element
Position of door lock switch
Enter, Clear, or
Down arrow
4
Press SET
Outer Broil Element
Run inner broil element
Enter, Clear, or
Down arrow
***If no amperage is read, check STEP 1 (Inner Bake Element). If amperage is read, the plug on the relay