Speed Control Interface
1.
Position:
2. Circuit:
3. The microcomputer will wait for
a speed information in order to
start.
4. The speed signal wave form (continuous pulse train) shall be as follows:
5. The maximum and minimum rating for speed input signals are:
INPUT VOLTAGE SYMBOL Min Type Max Unit
HIGH
Vhigh
4.5
5.0
5.5
V
LOW
Vlow
-0.2
0
0.2
V
REVERSE
VOLTAGE
VR
6
V
ISOLATION
VOLTAGE
(AC
for
1
min.)
Viso
5
V
FORWARD
CURRENT
IF
3
5
10
mA
REVERSE
CURRENT
IR
10
µ
A
The pulse frequency (edge sensitive, duty cycle from 10 to 90% is OK) will determine the motor
speed as shown in the curve below:
6. Minimum speed 1600RPM -- Maximum speed 4500 RPM
7. If the inverter does not receive the speed signal for more than 33 shaft turns, the motor stops.