Refrigeration and Freezer Compartment Theory of Operation
WARNING
To avoid electrical shock which can cause severe personal injury or death, disconnect power
to refrigerator using power switch before servicing. Wires removed during disassembly must
be replaced on proper terminals to insure correct earth ground and polarization. After
servicing, reconnect power using power switch.
If both freezer and fresh food thermistors are
warm, their resistance drops (see table
Refrigerator and Freezer Thermistor in
Temperature Control Section) and the electronic
signals for compressor / condenser fan motor
operation and for operation of fresh food fan. (See
previous section on Freezer and Refrigeration
Compartment Theory of Operation for adapter
board control.)
After freezer thermistor cools sufficiently to raise
resistance and block the signal to the
electronic
control,
compressor / condenser fan motor will shut off.
However, fresh food fan will continue to run
until fresh food thermistor cools and signal is
blocked to electronic control.
If fresh food thermistor cools before freezer
thermistor, electronic control will interrupt
circuit to fresh food fan while evaporator fan
motor will continue to operate under control
of freezer-thermistor.
34
Summary of Contents for DFSB483D
Page 1: ...VCSB483D DFSB483D DDSB483D COVER F90597...
Page 4: ...VCSB483D with ICE and WATER 4...
Page 5: ...CABINET AIR FLOW 5...
Page 6: ...MACHINE COMPARTMENT AIR FLOW 6...
Page 7: ...REFRIGERANT FLOW 7...
Page 8: ...WATER FLOW 8...
Page 27: ...VCSB483 WIRING DIAGRAM 27 27...
Page 28: ...VCSB483D WIRING DIAGRAM DISPENSER MODEL 28...
Page 38: ...CONTROL BOARD OPERATION 38...
Page 39: ...TROUBLESHOOTING 39...
Page 40: ...TROUBLESHOOTING con t 40...
Page 45: ...45...