CUSTOM WOOD FRAME INSTALLATION INSTRUCTIONS

(DFUR Model) 
Note:  Weight of wood panel must not exceed 20 lbs.

Wood Screws
1.  A #10 pan head wood screw should be used to properly secure the wood frame. A total of 8 screws will be needed

for a 3 1/2” (8.9 cm) kickplate or 7 screws for a 4” (10.2 cm) kickplate. 

2.  Only use pan head screws. 
3.  DO NOT select a screw that is longer than the wood thickness at

the screw locations. 

4.  Use recommended pilot holes for the frame material. (See chart) 

Working Material

Wood Screw Size #10

Hardwood 

3/32 (0.24 cm) 

Softwood 

5/64 (0.20 cm)

Assembling Door Hinge Brackets

(Disregard if hinge brackets are already attached) 

1.  Attach the top and bottom door hinge brackets to the door with the #10-32 machine screws and a 1/8” allen head

driver as shown in Figure 1 below. 

2.  Press in the shoulder bushings to the top and bottom door hinge brackets. Make certain that the shoulder is to the

outside of the door as shown in Figure 1 below. 

3.  Test fit the door to the unit to make certain door will hang correctly. The door is hung correctly when the top of the

door is parallel to the top of the unit. (See Figure 2) Adjustments can be made by loosening the door hinge
machine screws and moving the door hinge brackets on the door. 

4.  Tighten all four (4) machine screws after adjustments have been made. 
5.  Remove the door from the unit by removing the units top hinge set screw and angling the door off of the bottom

hinge pin. 

Figure 1

Figure 2

Shoulder Bushing

Door Hinge Bracket

#10-32 Machine

Screw

Door Hinge
Screw Holes

Door Front
Surface

This surface parallel to the unit.  
(Right hinge door shown

Typical Top and Bottom
Door Hinge Bracket
Assembly

6

AREA REQUIREMENTS
Units Certified for Indoor Use - (black outer cabinet)
1.  Place unit so the front side will be completely unobstructed to provide proper air flow.  The unit may be closed in

on the top and three sides, but the front MUST BE unobstructed for air circulation and proper operation.
Installation should be such that the cabinet can be moved for servicing if necessary.

2.  Unit should be in a well ventilated area with temperature above 55

0

F (13

0

C) and below 110

0

F (43

0

C).  Best results

are obtained at temperatures between 65

0

F (18

0

C) and 80

0

F (27

0

C) for built-in models and between 65

0

F (18

0

C) and

90

0

F (32

0

C) for freestanding models.

3.  Provisions for electricity should be determined before placing unit in proper place.

Units Certified for Outdoor Use - (stainless steel outer cabinet)
MUST BE INSTALLED IN AN AREA PROTECTED FROM THE ELEMENTS, SUCH AS WIND, RAIN, WATER (SPRAY OR DRIP).
1.  Place unit so the front side will be completely unobstructed to provide proper air flow.  The unit may be closed in

on the top and three sides, but the front MUST BE unobstructed for air circulation and proper operation.
Installation should be such that the cabinet can be moved for servicing if necessary.

2.  Unit should be in a well ventilated area with temperature above 40

0

F (4

0

C) and below 110

0

F (43

0

C).  

3.  Provisions for electricity should be determined before placing unit in proper place.

Note:  Hinge bracket location shown is for right-hinge swing.

Door swing pin

Top hinge
bracket

Logo

Bottom hinge

bracket

Light switch activator

REVERSIBLE DOOR (Glass Door Units Only)
PROFESSIONAL SERIES

You can change the door swing from right to left hinge very easily.
1.  Simply unscrew the top hinge door swing pin with an 1/8” allen

drive unit and lift door off of the bottom hinge bracket.  Flip the
door, remove the light switch activator and replace the light switch
activator on the other end of the door.

2.  Remove the door swing pin from bottom right hinge.  Move the

bottom, right hinge bracket to the upper, left side of the cabinet
and fasten it in place with its original mounting screws.  

3.  Install the hinge door swing pin into the top right hinge bracket

and move the bracket to the lower left side of the cabinet.  Fasten
it in place with its original screws.  

4.  Place the plastic washer over the bottom door swing pin on the

top surface of the bottom, left hinge.  

5.  Position the door on the bottom, left hinge pin and push the door

under the top, left hinge.  

6.  Line-up the top left hinge hole with the door bushing hole and

insert swing pin.   Screw down the door swing pin with the 1/8”
allen drive unit until its head is flush with the top surface of the
top, left hinge.  

7.  Reposition the logo.  Your installation is now complete.

GENERAL INFORMATION

Unpack
1.  Remove banding from bottom of carton.  Lift carton up and off of the refrigerated beverage center
2.  Remove all tape and packaging material from the outside and inside of the cabinet.
3.  Keep all carton packaging until your refrigerated beverage center has been thoroughly inspected and found to be in

good condition.

Summary of Contents for DFUR154

Page 1: ...ont Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com Viking Use Installation Guide 15 Wide Undercounter Freestanding Refrigerated Beverage Center ...

Page 2: ... responsibility to be sure your refrigerated beverage center is located so the front is not blocked to restrict incoming or discharge air flow properly leveled located in a well ventilated area connected to the proper kind of outlet with the correct electric supply and grounding A 115 volt 60 Hz 15 amp fused electrical supply is required NOTE Time delay fuse or circuit breaker is recommended not u...

Page 3: ...m 21 3 16 53 8 cm 23 5 8 60 0 cm 24 5 8 62 5 cm 21 3 16 53 8 cm 23 7 16 59 5 cm 37 3 16 94 5 cm 37 3 16 94 5 cm to front of locally supplied custom panel 4 SPECIFICATIONS DIMENSIONS PROFESSIONAL SERIES Basic Electric Data 115 VAC 60 Hz Maximum amps 3 0 Approximate Shipping Weight 110 lbs 49 5 kg Front View Side View 30 3 4 78 1 cm Min 34 1 4 87 0 cm to Max 35 88 9 cm with leveling legs fully exten...

Page 4: ... 180 C and 900 F 320 C for freestanding models 3 Provisions for electricity should be determined before placing unit in proper place Units Certified for Outdoor Use stainless steel outer cabinet MUST BE INSTALLED IN AN AREA PROTECTED FROM THE ELEMENTS SUCH AS WIND RAIN WATER SPRAY OR DRIP 1 Place unit so the front side will be completely unobstructed to provide proper air flow The unit may be clos...

Page 5: ...et Hinge Wood Frame Door Hinge Door Hinge Shoulder bushing 3 4 OD x 7 16 ID Washer 3 4 OD x 1 4 ID Washer 3 Nylon hardware components at bottom hinge CAUTION Door may not swing properly if all nylon components are not installed as shown Bottom Hinge Cover Wood Frame Hinge Hardware Installation Details Magnetic door gasket Rear of Door Door light striker plate Bottom of door Door hinge adjustment s...

Page 6: ... soapy water If buildup occurs do not use steel wool abrasive cloths cleaners or powders If it is necessary to scrape stainless steel to remove encrusted materials soak with hot wet cloths to loosen the material then use a wood or nylon scraper Do not use a metal knife spatula or any other metal tool to scrape stainless steel scratches are almost impossible to remove WIRING DIAGRAM UNDERCOUNTER 15...

Page 7: ...12 OPERATING INSTRUCTIONS Setting the Controls The total available temperature range of the indoor unit is from 39 420 F 4 0 5 60 C to 54 560 F 12 130 C The total available temperature range of the outdoor unit is from 33 350 F 0 5 1 10 C to 54 560 F 12 130 C The higher the number selected the cooler the temperature within the unit As with any refrigerated beverage center there is a slight tempera...

Page 8: ...or service or part there of which gives rise to the claim WARRANTY SERVICE Under the terms of this warranty service must be performed by a factory authorized Viking Range Corporation service agent or representative Service will be provided during normal business hours and labor performed at overtime or premium rates shall not be covered by this warranty To obtain warranty service contact the deale...

Page 9: ...uct by anyone other than an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from indoor units being used in outdoor situations This warranty does not apply to commercial usage Warrantor is not responsible for consequential or incidental damage whether arising out of breach of warranty breach of contract or otherwise Some jurisdictio...

Reviews: