9
Attaching the Wood Frame to the Door - DFUR Models
1. If the door is attached to the unit, remove by unscrewing the top allen head set screw at the top hinge. Remove
the door by angling the door off of the bottom hinge pin.
2. Peel back the door gasket to expose the screw holes.
3. Set the wood frame flush to the front of the door in the desired location. Clamp the wood frame to the door if
necessary.
4. Insert the wood screws through the back of the door into the pilot holes in the wood frame and tighten.
5. Reinstall the door gasket by pressing into the door channel. Make certain the corners are inserted fully.
6. Install the door to the unit. Use the supplied plastic washer as shown in the figure below.
7. Realigning the door may be necessary. Any final door adjustments can be made using a 1/8” allen head driver to
adjust the door’s hinges. (See figure below)
8. Attach the door light striker plate as shown using the 5/16” hex or phillips head screws provided. Make certain the
light is able to turn on and off when the door is opened and closed.
9. Attach the door to the unit by reversing step number 1 above.
CAUTION
Door can become
disengaged if washers
are not installed.
CAUTION
Door can become
disengaged if
washers are not
installed.
Cabinet
Hinge
Wood
Frame
Door Hinge
Door Hinge
Shoulder bushing
3/4” OD x 7/16”
ID Washer
3/4” OD x 1/4” ID
Washer
(3) Nylon hardware
components at
bottom hinge
CAUTION
Door may not swing properly
if all nylon components are
not installed as shown
Bottom Hinge Cover
Wood Frame
Hinge Hardware Installation
Details
Magnetic door gasket
Rear of Door
Door light striker plate
Bottom of
door
Door hinge adjustment
screws
Attached wood
frame
5/8”x 7/32” ID washer
Shoulder
bushing
3/8” clearance holes
for frame wood screws
- 8 holes
(2) Nylon
hardware
components at
top hinge
Top Hinge Cover
1/8” allen head screws for hinge
adjustment
8
Selecting and Preparing the Wood Frame - DFUR Model
FOR A 3-1/2” TOE KICK
(COVERS THE ENTIRE DOOR EXTRUSION)
1/4” X 3/8” Deep hinge screw clearance hole. Locate and drill using
door hinge hole after the door has been aligned to the unit and when
the wood is positioned on door
1/4” X 3/8” Deep hinge screw clearance hole. Locate and drill using
door hinge hole after the door has been aligned to the unit and
when the wood is positioned on door
Mounting surface
(Non-face) side
Mounting surface
(non-face) side
Mounting surface
(non-face) side
Min. 5/8” (1.7 cm)
Max. 3/4” (1.9 cm)
14 5/16”
(36.4 cm)
7 5/32” (18.2 cm)
23/32”
(1.8 cm) TYP
1 23/32” (4.4) cm min.
width to cover door
extrusion
23/32”
(1.8 cm)
TYP
BACK
VIEW
OF
OVERLA
Y P
ANEL
30 5/16”
(77.0 cm)
Pre-drilled piolt holes -
8 places
7 13/16”
(19.8 cm)
TYP
15 5/32”
(38.5 cm)
TYP
22 1/2”
(57.2 cm)
TYP
15./2” (1.2 cm)