background image

Due to the dynamic nature of the product design, the information contained in this document is subject to change without notice. Viking Electronics, and its affiliates and/or
subsidiaries assume no responsibility for errors and omissions contained in this information. Revisions of this document or new editions of it may be issued to incorporate
such changes.

Fax Back Doc 210

ZF301780 Rev A

Printed in the U.S.A.

P

P

r

r

o

o

d

d

u

u

c

c

t

t

S

S

u

u

p

p

p

p

o

o

r

r

t

t

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

8

8

6

6

6

6

6

6

F

F

a

a

x

x

B

B

a

a

c

c

k

k

L

L

i

i

n

n

e

e

.

.

.

.

.

.

7

7

1

1

5

5

.

.

3

3

8

8

6

6

.

.

4

4

3

3

4

4

5

5

C. Changing the Call Time-Out

The 

E-10

and 

E-20A

are equipped with an adjustable call time-out feature which automatically hangs-up the unit after

the pre-set time has elapsed. To change the time-out, adjust the call time pot as shown above.  The time can be adjust-
ed from approximately 6 seconds to 5 minutes (factory set to approximately 3 minutes).

P

P

r

r

o

o

g

g

r

r

a

a

m

m

m

m

i

i

n

n

g

g

A. Adjusting Speaker Volume

The 

SPKR VOL

pot can be adjusted to increase or decrease the speaker volume to the level desired as shown above.

B. Adjusting the Microphone Volume

In certain noisy locations (background traffic, machinery or wind), the microphone volume may need to be decreased.
A symptom of this is one-way talk path, in which the distant party cannot be heard over the speaker.  A

MIC VOL

pot

is provided for increasing or decreasing the microphone volume.  

Note: 

If the microphone volume is set too high or too

low, one-way talk path may occur.

D. DIP Switch Programming

DIP switch 1 is for turning the Auto Answer feature ON and
OFF. The speaker phones are factory set to auto answer
when an inbound call is detected.  

1   2   3

ON

DIP

Switches

OFF   ON

Speaker Volume

(see section A)

-or-

E-10/E-20A E-10-EWP/E-20A-EWP

Microphone Volume

(see section B)

-or-

E-10/E-20A E-10-EWP/E-20A-EWP

Call Timer

(see section C)

-or-

E-10/E-20A E-10-EWP/E-20A-EWP

1. Auto Answer Feature ON/OFF (DIP Switch 1)

The call timer switch allows the user to turn off/disable the
call timer feature.  With DIP switch 2 in the OFF position, the
call time will be unlimited and the speaker phone will not
automatically hang up until a 300ms or longer CPC break is
detected.  

Warning:

If your telephone line/phone system

extension does not supply a 300ms or longer CPC break, the call timer feature must be used, DIP switch 2 ON.

2. Call Timer ON/OFF (DIP Switch 2)

With DIP switch 3 in the ON position (factory default), the VOX switching speed (delay time between talk and listen
mode) is set to FAST (0.3 seconds). In the OFF position, it is set to SLOW (0.7 seconds).

3. VOX (Talk/Listen) Switching Speed (DIP Switch 3)

Rear View of Speaker Phone models:

E-10/E-20A/E-10-EWP/E-20A-EWP

DIP

Switch

1

1

2

2

3

3

Position

ON

OFF

ON

OFF

ON

OFF

Description

Auto-Answer ON (factory default)

Auto-Answer OFF

Call Timer ON (factory default)

Call Timer OFF

VOX Speed Fast (factory default)

VOX Speed Slow

Note: 

Pots are shown in factory default settings.

Summary of Contents for E-10

Page 1: ...L S Sp pe ec ci if fi ic ca at ti io on ns s F Fe ea at tu ur re es s Telephone line powered Weather resistant Optional Enhanced Weather Protection EWP Adjustable microphone and speaker volume Adjustable call time out to limit prank calls and false alarms approximately 6 seconds 5 minutes Call timer ON OFF switch Selectable auto answer feature allows remote monitoring Two way handsfree communicati...

Page 2: ...duplicate problem frequency of failure etc 2 Packing Return equipment in original box or in proper packing so that damage will not occur while in transit Static sensitive equipment such as a circuit board should be in an anti static bag sandwiched between foam and individual ly boxed All equipment should be wrapped to avoid packing material lodging in or sticking to the equipment Include ALL parts...

Page 3: ...E 10 E 10 EWP DLE 200B Two Way Ringdown Circuit not included C O Line or analog PABX KSU station programmed for ringdown Gel Filled Butt Connectors EWP Only To dedicated phone or unused trunk line input of phone system IMPORTANT Electronic devices are susceptible to lightning and power station electrical surges from both the AC outlet and the telephone line It is recommended that a surge protector...

Page 4: ...ed for increasing or decreasing the microphone volume Note If the microphone volume is set too high or too low one way talk path may occur D DIP Switch Programming DIP switch 1 is for turning the Auto Answer feature ON and OFF The speaker phones are factory set to auto answer when an inbound call is detected 1 2 3 ON DIP Switches OFF ON Speaker Volume see section A or E 10 E 20A E 10 EWP E 20A EWP...