GRAVITY DRAIN PUMP MODEL DRAIN INSTALLATION

1. Place the ice machine in front of the installation opening. Adjust leveling legs to the approximate height.
2. Insert drain tube through the routing hole in the back panel.
3.  Remove the upper back panel if needed for access to drain connection.

Note: If you are connecting a gravity drain model and the drain opening has been located in the floor under the base
pan according to the pre install specifications, follow steps 3 through 5 to drain the unit through the base. If not,
proceed to step 6b.

4. Remove the clamp and barbed elbow and take off the plastic cover in the base pan below the drain hose.
5. Connect a straight 5/8” barbed connector to the drain hose, securing with the clamp removed in step 4.
6. Cut an 8” piece of 5/8” ID X 7/8” OD tygon (clear plastic) tubing. Slide one end of the tube onto the outlet of the

barbed connector and secure with a clamp. Leave the other end of the tube lying on the floor of the base pan until
the unit is positioned over the floor drain.

7. Route the drain tube. Either a) Insert the drain tube through the base pan into the floor drain or b) Route the drain

tube through the left hole in the lower back panel and connect to barbed elbow and secure with a clamp.

8. Reinstall any panels removed.

Back View, Gravity Drain Model

Water Inlet
Tube (field
supplied)

Drain Hose

Barbed Elbow

Drain Hose,
Route to
building drain

CAUTION

Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice. Gravity drain tubing
must be vented, have no kinks and slope to the building drain. Air gaps are typically required by local code.

WATER & DRAIN INSTALLATION

The recommended water supply tubing is 1/4” OD copper. Stainless steel flex or reinforced PVC tube may also be
used. Install an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be
installed behind the unit.

The water connection is at the back of the cabinet.  Connect using a
compression fitting, one is supplied tied to the water inlet tube at the back
of the cabinet.  

When built-in:  Coil enough tubing behind the machine so it can be pushed
into the cavity without kinking the tubing.

DRAINS

There are two types of ice machine models, one that drains by gravity and
one that has an internal drain pump.

Drain Pump Model drain installation
1. Locate the coil of 3/8” ID plastic drain tubing secured to the back of the unit.
2. Route the plastic drain tube from the back of the unit to the drain connection point.

The drain connection can be as high as 10 feet (3.05 m) above the ice machine.  the drain pump includes a check valve
to prevent re-pumping water into the drain hose.

IMPORTANT NOTE: Often an air gap is required by local codes between the ice maker drain tube and the drain
receptacle.

Back View, Drain Pump Model

Water Inlet
Tube (field
supplied)

Drain Tube,
Route to
building drain

Connect water supply
here,  Fitting is supplied
in bag tied to tube.

Installation (con’t)

Installation (con’t)

Summary of Contents for FGNI515

Page 1: ...ront Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit our web site at vikingrange com in the US or brigade ca in Canada UL C UL Installation Guide 15 W Undercounter Freestanding Nugget Ice Machine ...

Page 2: ...nty Please observe all local and national codes and ordinances Please ensure that this product is properly grounded The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference A GFI shall be used if required by NFPA 70 National Electric Code federal state local laws or local ordinances The required use of a GFI is normally re...

Page 3: ...ance in a way that minimizes the possibility that children will find it There have been many cases in years past of children crawling inside junked and abandoned refrigeration units and becoming trapped or suffocated Contact your municipal waste disposal authority to find out the best and safest way to dispose of your old refrigeration unit 14 3 4 37 5 cm 3 7 8 9 8 cm Floor drain access hole 90 0 ...

Page 4: ...5 9 cm 22 3 4 57 8 cm 25 1 4 64 1 cm Cutout width 15 38 1 cm Cutout height 34 1 4 86 4 cm min to 35 1 4 89 5 cm max Cutout depth 24 61 0 cm Electrical requirements 115V 60 Hz 15 amp dedicated circuit 6 3 wire cord attached to product Maximum amp usage 5 0 amps Inlet water requirement 1 4 OD copper tubing inlet waterline 20 psi min to 80 psi max 50 F 10 C min to 100 F 38 C max Drain requirements 5 ...

Page 5: ...plied with ice machine 1 Remove the gasket and retain for later use 2 If the door panel is stainless steel remove any plastic covering the stainless steel panel 3 Place the panel onto the outside of the door and secure it to the door using two machine screws located at the left center and right center behind door gasket 4 Fasten the panel to the door using the 6 screws supplied with door panel In ...

Page 6: ...op of door and bottom of countertop edge from cabinet opening This is the maximum door length 5 Cut panel to width 6 Cut panel to length cabinet space kickplate space top clearance length 7 Determine top of panel 8 Mark hole locations using drawing on the back of these instructions Drawing assumes top of panel will be flush with top of door Measure hole locations from the top of the panel 9 Drill ...

Page 7: ...at insert a stop into the provided hole in the top and bottom hinges Drive the pin into the hole until the head is against the hinge HINGE COVERS After the hinge pins are installed if used and the door panel has been attached attach the hinge covers 1 Slide the hinge cover over each hinge 2 Attach the side cover over the hinge by peeling off the covering over the adhesive and placing it over the s...

Page 8: ...ION Restrictions in the drain system to the machine will cause water to back up into the ice storage bin and melt the ice Gravity drain tubing must be vented have no kinks and slope to the building drain Air gaps are typically required by local code WATER DRAIN INSTALLATION The recommended water supply tubing is 1 4 OD copper Stainless steel flex or reinforced PVC tube may also be used Install an ...

Page 9: ...REFERENCE Model and Serial number The ice machine is supplied with a power cord DO NOT remove the grounding pin from the cord s plug DO NOT use extension cords Follow all codes Connect the machine to its own 115 volt 15 amp circuit FINAL INSTALLATION 1 If the electrical outlet for the ice maker is behind the unit plug in the unit 2 Snap the black caps over the bottom of the leveling legs 3 Positio...