SPRINKLER VK354 (K8.0)

TECHNICAL DATA

Page 1 of 3

The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058

Telephone: 269-945-9501  Technical Services: 877-384-5464  Fax: 269-818-1680  Email: techsvcs@vikingcorp.com

Visit the Viking website for the latest edition of this technical data page www.vikinggroupinc.com.

Form No. F_033214     18.11.05     Rev 18.3.P65

1.  DESCRIPTION

The Viking Microfast

®

 Quick Response Conventional (Old Style) Sprinkler 

VK354 is a small, thermosensitive, glass-bulb spray sprinkler available in sev-

eral different finishes, temperature ratings, and K-Factors to meet design re-

quirements. The special Polyester, and Electroless Nickel PTFE (ENT) coatings 

can be used in decorative applications where colors are desired. In addition, 

these coatings have been investigated for installation in corrosive atmospheres 

and are listed/approved as corrosion resistant as indicated in the Approval 

Charts. 

2.  

LISTINGS AND APPROVALS

cULus Listed: 

Category VNIV

LPCB Approved: 

Certificate 096e/03

CE Certified: 

Standard EN 12259-1, EC-certificate of constancy of performance 0832-CPR-S0021

MED Certified:

 Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003

NOTE: 

Other International approval certificates are available upon request.

Refer to Approval Chart 1 and Design Criteria for cULus Listing requirements.

3.  TECHNICAL DATA

Specifications:

Minimum Operating Pressure: 7 psi (0.5 bar)* 

Maximum Working Pressure: 175 psi (12 bar) wwp. 

Factory tested hydrostatically to 500 psi (34.5 bar)

Testing: U.S.A. Patent No. 4,831,870

Thread size: 3/4” NPT, 20 mm BSP

Nominal K-Factor: 8.0 U.S. (115.2 metric**)

 

Glass-bulb fluid temperature rated to -65 °F (-55 °C)

Overall Length: 2-5/16” (59 mm)

 *cULus Listing and NFPA 13 installs require a minimum of 7 psi (0.5 bar). The minimum operating pressure for LPCB and CE Approvals ONLY is 5 

psi (0.35 bar). 

** Metric K-factor measurment shown is in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0.

Material Standards:

Frame Casting: Brass UNS-C84400 or QM Brass

Deflector: Brass UNS-C26000

Bulb: Glass, nominal 3 mm diameter

Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with PTFE Tape

Screw: Brass UNS-C36000

Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400

For Polyester Coated Sprinklers:

 

Belleville Spring-Exposed

For ENT Coated Sprinklers: Belleville Spring-Exposed, Screw and Pipcap-ENT plated

Ordering Information:

 (Also refer to the current Viking price list.)

Order Viking Microfast

®

 Quick Response Conventional (Old Style) Sprinkler VK354 by first adding the appropriate suffix for the 

sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. 

Finish Suffix: Brass = A, Chrome = F, White Polyester = M-/W, Black Polyester = M-/B, and ENT = JN

Temperature Suffix (°F/°C): 135°/57° = A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G

For example, sprinkler VK354 with a 3/4” thread, Brass finish and a 155 °F/68 °C temperature rating = Part No. 18261AB

Available Finishes And Temperature Ratings: 

Refer to Table 1.

Accessories:

 (Also refer to the Viking website.)

Sprinkler Wrench: 

Standard Wrench: Part No. 21475M/B (available since 2017)

 

Replaces Form No. F_060714 Rev 18.3

(Added P65 Warning.)

NOTE: As of May 2018 all logos have been removed from 

the wrench boss.

Summary of Contents for MICROFAST VK354

Page 1: ...tent No 4 831 870 Thread size 3 4 NPT 20 mm BSP Nominal K Factor 8 0 U S 115 2 metric Glass bulb fluid temperature rated to 65 F 55 C Overall Length 2 5 16 59 mm cULus Listing and NFPA 13 installs require a minimum of 7 psi 0 5 bar The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi 0 35 bar Metric K factor measurment shown is in Bar When pressure is measured in kPa divide the m...

Page 2: ...ist price schedule or contact Viking directly TABLE 1 AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Classification Sprinkler Nominal Temperature Rating1 Maximum Ambient Ceiling Temperature2 Bulb Color Ordinary 135 F 57 C 100 F 38 C Orange Ordinary 155 F 68 C 100 F 38 C Red Intermediate 175 F 79 C 150 F 65 C Yellow Intermediate 200 F 93 C 150 F 65 C Green High 286 F 141...

Page 3: ... Chart 1 UL Viking Microfast Quick Response Conventional Sprinkler VK354 Maximum 175 PSI 12 bar WWP Base Part Number1 SIN Thread Size Nominal K Factor Overall Length Listings and Approvals3 Refer also to Design Criteria NPT BSP U S metric2 Inches mm cULus4 VdS LPCB 8 18261 VK354 3 4 20 mm 8 0 115 2 2 5 16 59 A1 A2 B27 B2 NOTICE Product Below Limited Availability Contact Local Viking Office 06768B ...

Page 4: ... the model of sprinkler used DO NOT install sprinklers onto piping at the floor level Install sprinklers after the piping is in place to prevent mechanical damage DO NOT allow impacts such as hammer blows directly to sprinklers or to fittings pipe or couplings in close proximity to sprinklers Sprinklers can be damaged from direct or indirect impacts DO NOT attempt to remove drywall paint etc from ...

Page 5: ...CAPS MUST BE REMOVED FROM SPRINKLERS BEFORE PLACING THE SYSTEM IN SERVICE Figure 1 Sprinkler shield being removed from a pendent sprinkler Figure 2 Sprinkler cap being removed from a pendent sprinkler Figure 3 Sprinkler cap being re moved from and upright sprinkler HOW TO REMOVE SHIELDS AND CAPS No tools are necessary to remove the shields or caps from sprinklers DO NOT use any sharp objects to re...

Page 6: ...hese sprinklers NOTE The protective cap is temporarily removed during installation and then placed back on the sprinkler for protection until finish work is completed Do not over tighten the sprinklers into fittings during installation Do not use the sprinkler deflector to start or thread the sprinklers into fittings during installation Do not attempt to remove drywall paint etc from the sprinkler...

Page 7: ...r installation to protect the corrosion resistant properties of the sprinkler Use care when locating sprinklers near fixtures that can generate heat Do not install sprinklers where they would be exposed to temperatures exceed ing the maximum recommended ambient temperature for the temperature rating used Inspect the coated sprinklers frequently soon after installation to verify the integrity of th...

Page 8: ...ction of fire protection products are provided herin as they relate to legally mandated jurisdictional regions WARNING STATE OF CALIFORNIA USA Installing or servicing fire protection products such as sprinklers valves piping etc can expose you to chemicals including but not li mited to lead nickel butadiene titaninum dioxide chromium carbon black and acrylonitrile which are known to the State of C...

Reviews: