Saw, deburr, and clean the pipe
FIGURE 5-43: Sawing device
1. Clamp the pipe in a sawing device so the pipe is not deformed.
2. Cut the pipe to length with a hacksaw. Do not use any pipe cutter or angle grinder.
Pipe Outer Diameter
0.24 inches (6 mm)
0.39 inches (10 mm)
Straight minimum pipe length H
min
(without bending)
1
1.38 inches
2
(35 mm)
1.58 inches
2
(40 mm)
Minimum installation length L
min
1.77 inches
(45 mm)
1.97 inches
(50 mm)
1
The straight pipe end must not deviate from the dimension tolerance of the pipe in accor-
dance with DINEN10305-1 regarding roundness and straightness in the entire zone “H”.
2
If twice the height of the union nut is a higher value, maintain the higher value.
Summary of Contents for Oxeo
Page 1: ...Installation and Maintenance Manual Oxeo Inert Gas Extinguishing System...
Page 10: ...Inst and Maint Manual Oxeo PR LCP F_101921 Rev 02 10 2022 en 4...
Page 32: ...Inst and Maint Manual Oxeo PR LCP F_101921 Rev 02 10 2022 en 26...
Page 42: ...Inst and Maint Manual Oxeo PR LCP F_101921 Rev 02 10 2022 en 36...
Page 134: ...Inst and Maint Manual Oxeo PR LCP F_101921 Rev 02 10 2022 en 128...
Page 148: ...Inst and Maint Manual Oxeo PR LCP F_101921 Rev 02 10 2022 en 142...
Page 156: ...Inst and Maint Manual Oxeo PR LCP F_101921 Rev 02 10 2022 en 150...
Page 176: ...Inst and Maint Manual Oxeo PR LCP F_101921 Rev 02 10 2022 en 170...
Page 206: ...Inst and Maint Manual Oxeo PR LCP F_101921 Rev 02 10 2022 en 200...
Page 220: ...Inst and Maint Manual Oxeo PR LCP F_101921 Rev 02 10 2022 en 214...
Page 221: ...Oxeo PR LCP 10 2022 en 215 15 SafetyDataSheet IG 01 Argon...
Page 228: ...Oxeo PR LCP 10 2022 en 222...
Page 229: ...Oxeo PR LCP 10 2022 en 223 16 SafetyDataSheet IG 100 Nitrogen...
Page 236: ...Oxeo PR LCP 10 2022 en 230...
Page 237: ......