To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
WARNING
!
Disassembly
©2012 Viking Preferred Service
25
The 30” unit uses a fan motor to pull air over
the evaporator coil and circulate it throughout
the unit.
The 36” unit uses two fan motors to pull
air over the evaporator coil and circulate it
throughout the unit.
Freezer Fan
Note:
The trim pieces and slide mounts
have a clip attached that engages in a
catch. To remove assembly, disengage clip
from catch.
1. To access the freezer fan,
remove all shelves, drawers,
and ice maker (see Ice Maker
section).
2. Remove lower light covers (see
lower light section) and left and
right trim pieces.
3. Remove left and right slide mounts.
4. Remove screws, remove rear cover, and
disconnect wiring.
30” Unit
Summary of Contents for Quiet Cool VCFB5301
Page 48: ...Schematic 48 2012 Viking Preferred Service 30 All Freezer Schematic Upper Section...
Page 49: ...Schematic 2012 Viking Preferred Service 49 30 All Freezer Schematic Lower Section...
Page 50: ...Schematic 50 2012 Viking Preferred Service 36 All Freezer Schematic Upper Section...
Page 51: ...Schematic 2012 Viking Preferred Service 51 36 All Freezer Schematic Lower Section...
Page 52: ...Wiring Diagrams 52 2012 Viking Preferred Service UPPER SECTION WIRING 30...
Page 53: ...Wiring Diagrams 2012 Viking Preferred Service 53 LOWER SECTION WIRING 30...
Page 54: ...Wiring Diagrams 54 2012 Viking Preferred Service UPPER SECTION WIRING 36...
Page 55: ...Wiring Diagrams 2012 Viking Preferred Service 55 LOWER SECTION WIRING 36...