To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
WARNING
!
Troubleshooting
©2012 Viking Preferred Service
41
High Voltage Board
Component
Test
Point
Reading
Refrigerator/Con-
densate Fans
E1-E11
24 VDC
Evaporator Fans
E2-E11
115 VAC
L1
E3-E11
115 VAC
Compressor / Con-
denser Fan
E4-E11
115 VAC
Defrost Terminator
(closed)
E5-E11
0 VAC
Defrost Terminator
(open)
E5-E11
115 VAC
Defrost Heater
E6-E11
115 VAC
Ref door switch (top
right light)
E7-E11
115 VAC
Freezer door switch
(left light)
E8-E11
115 VAC
Neutral In
E9-E11
N/A
Line In
E10-E11 115 VAC
Ground
E11
N/A
Neutral In (lights)
E12-E11 N/A
Neutral Out (lights)
E13-E11 115 VAC
Aux Heater (Dis-
penser units only)
E14-E11 115 VAC
E11 Ground
E1 Refrigerator/
Condensate Fans
E4 Compressor
E3 Line In–120 VAC
E2 Evaporator Fan
E7 Refrigerator Door
Switch
E8 Freezer Door Switch
E9 Neutral
L1 Line In - 120 VAC
E5 Defrost Terminator
E6 Defrost Heater
E12 Neutral in
E13 Light Relay
E14
E14 Aux Heater
High Voltage Board
Summary of Contents for Quiet Cool VCFB5301
Page 48: ...Schematic 48 2012 Viking Preferred Service 30 All Freezer Schematic Upper Section...
Page 49: ...Schematic 2012 Viking Preferred Service 49 30 All Freezer Schematic Lower Section...
Page 50: ...Schematic 50 2012 Viking Preferred Service 36 All Freezer Schematic Upper Section...
Page 51: ...Schematic 2012 Viking Preferred Service 51 36 All Freezer Schematic Lower Section...
Page 52: ...Wiring Diagrams 52 2012 Viking Preferred Service UPPER SECTION WIRING 30...
Page 53: ...Wiring Diagrams 2012 Viking Preferred Service 53 LOWER SECTION WIRING 30...
Page 54: ...Wiring Diagrams 54 2012 Viking Preferred Service UPPER SECTION WIRING 36...
Page 55: ...Wiring Diagrams 2012 Viking Preferred Service 55 LOWER SECTION WIRING 36...