To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
WARNING
!
Troubleshooting
©2012 Viking Preferred Service
43
Troubleshooting Guide
Below and on the following page are some general guides should a problem be detected. Please
refer to the test procedures in this manual to determine the defective component.
Problem
Probable Cause
Correction
Unit will not operate
Power supply
Circuit breaker
Power switch
Verify voltage
Reset breaker
Turn to the “ON” position
Water over
fl
ows
defrost pan
Unit not level
Float switch
Pan heater
Ensure unit is level
Verify operation of
fl
oat switch
Verify heater is working
Ice maker will not operate Freezer too warm
Shut off arm
Open TCO or defective ice maker
Water valve
Water supply
Verify freezer temperature
Verify the arm is in the “ON” position
Replace Ice Maker
Verify valve operation
Verify water supply
Freezer too warm
(AF Model)
Control setting
Door seal
Dirty condenser Defective thermistor
Control board
Move control to medium setting
Verify closure, replace if needed
Clean condenser coil
Replace thermistor
Verify operation
Freezer too cold
(AF Model)
Temperature setting
Defrost thermostat
Defective thermistor
Control board
Move to medium setting
Verify thermostat is closing
Replace thermistor
Verify operation
Unit runs continually
Control setting
Door seal
Dirty condenser
Condenser/evaporat
or fan Defective
thermistor Control
board
Move to medium setting
Verify closure, replace if needed
Clean condenser coil
Verify movement/operation of fan
Replace thermistor
Verify operation
Frost on evaporator
Defrost thermostat
Evaporator fan
Defrost heater
Door not sealing
properly
Check indicator
Check connection and possible short open condition
Check connection and possible short open condition
Adjust door seal or replace.
Unit running and no lights Sabbath Mode
Open circuit
Take out of Sabbath Mode
Repair/replace wiring
Summary of Contents for Quiet Cool VCFB5301
Page 48: ...Schematic 48 2012 Viking Preferred Service 30 All Freezer Schematic Upper Section...
Page 49: ...Schematic 2012 Viking Preferred Service 49 30 All Freezer Schematic Lower Section...
Page 50: ...Schematic 50 2012 Viking Preferred Service 36 All Freezer Schematic Upper Section...
Page 51: ...Schematic 2012 Viking Preferred Service 51 36 All Freezer Schematic Lower Section...
Page 52: ...Wiring Diagrams 52 2012 Viking Preferred Service UPPER SECTION WIRING 30...
Page 53: ...Wiring Diagrams 2012 Viking Preferred Service 53 LOWER SECTION WIRING 30...
Page 54: ...Wiring Diagrams 54 2012 Viking Preferred Service UPPER SECTION WIRING 36...
Page 55: ...Wiring Diagrams 2012 Viking Preferred Service 55 LOWER SECTION WIRING 36...