36”
(91.
1 cm)
10-1/4”
(26.0 cm)
14”
(35.6 cm)
5”
(12.7
cm)
5”
(12.
7 cm)
6” m
in.
(15.2
cm)
27
-1/2”
(69.
9 cm)
Gas inlet
pipe location
36”
(91.
1 cm)
10-
1/4”
(26.0 cm)
24-3/4”
(62.9
cm)
5”
(12.
7 cm)
6”
mi
n.
(15.
2 cm)
27
-1/2”
(69
.9
cm)
5”
(12.7
cm)
Gas inlet
pipe location
OUTDOOR—COOKING
Built-In Gas Side Burner, 24”W. Rangetop,
Wok/Cooker, & TruSear
™
Infrared Grillers
P L A N N I N G A N D D E S I G N G U I D E
V I K I N G R A N G E . C O M • 1 - 8 8 8 - V I K I N G 1
R E L E A S E D 1 2 / 1 / 0 7
© 2 0 0 7 V R C — INFORMATION SUBJECT TO CHANGE
Dimensions & Specifications
CUTOUT DIMENSIONS
VGSB152T/VGIB151T
VGRT244T/VGWT241T/VGIB242T
VGSB152T
VGRT244T
VGWT241T
VGIB151T
VGIB242T
Cutout width
14” (35.6 cm)
24-3/4” (62.9 cm)
24-3/4” (62.9 cm)
14” (35.6 cm)
24-3/4” (62.9 cm)
Cutout height
10-1/4” (26.0 cm)
Cutout depth
27-1/2” (69.9 cm)
27-1/2” (69.9 cm)
27-3/8”(69.5 cm) min. to
27-1/2” (69.9 cm)
27-1/2” (69.9 cm)
27-7/8” (70.8 cm) max.
15”W. SIDEBURNERS & GRILLERS
1. Maintain a minimum of 6” (15.2 cm)
from the sides of the side burners
(above the cooking surface) to
adjacent vertical combustible
construction. Do not install under
overhead, unprotected combustible
construction.
2. Allow at least 6” side clearance to
non-combustible construction above
the cooking surface for counter space.
3. When choosing a suitable location,
consider factors such as wind
exposure, proximity to traffic paths,
keeping gas supply lines as short as
possible. Install only in a well-
ventilated area. Never install in a
building, garage, breezeway, shed, or
other such fully enclosed areas.
24”W. RANGETOP/WOK/GRILLER
PROXIMITY TO CABINET INSTALLATION
The unit may be installed directly
adjacent to the existing base cabinets.
The side trim must be 3/8” (0.95 cm)
above the adjacent base cabinet
countertop. There is a 0” side and rear
clearance to non-combustible surfaces.
The unit cannot be installed directly
adjacent to combustible sidewalls. There
must be a minimum of 6” (15.2 cm) side
and rear clearance from the unit to such
combustible surfaces. This unit cannot be
placed under an overhead which is
unprotected and combustible.