background image

3

G

GA

AS

S  C

CO

ON

NN

NE

EC

CT

TIIO

ON

N

Verify the type of gas supply to be used, either natural or LP, and make sure the marking on the rating plate

agrees with that of the supply.  Never connect an unregulated gas line to the appliance.  An installer supplied gas shut-
off valve must be installed in an easily accessible location.  All installer supplied parts must conform to local codes, or
in the absence of local codes, with the National electrical Code, ANSI/NFPA 70 and the National Fuel Code, ANSI
Z223.1.  IIn

n  C

Caan

naad

daa::    Installation must be in accordance with the current CAN/CGA-B149.1, Natural Gas Installation

Code or CAN/CGA-B149.2, Propane Installation Code and/or local codes.  All pipe sealants must be an approved type
and resistant to the actions of LP gas.  Never use pipe sealant on flare fittings.  All gas connections should be made by
a competent technician and in accordance with local codes and or ordinances.  In the absence of codes, the installation
must comply with the National Fuel Gas Code ANSI Z223.1.  

The gas burner and its individual shut-off valve must be disconnected from the gas supply piping system

during any pressure testing of that system at test pressures in excess of 1/2 PSIG (3.5 kPa).  The unit must be isolated
from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of that
system at test pressures equal to or less than 1/2 psi (3.5 kPa).

B

BA

AS

SIIC

C  S

SP

PE

EC

CIIF

FIIC

CA

AT

TIIO

ON

NS

S

D

De

essccrriip

pttiio

on

n

V

VG

GIIB

B1

15

51

1T

T

V

VG

GIIB

B2

24

42

2T

T

Overall Width

15-5/16”  (38.9 cm)

26 1/4” (66.7 cm)

Overall Depth

To end of landing ledge 

31-9/16”  (80.2 cm)

To end of knobs

32-5/8” (82.9 cm)

Overall Height

10 1/2” (26.3 cm)

Cutout Width

14” (35.6 cm)

24 3/4” (62.9 cm)

Cutout Depth

27-1/2” (69.9 cm)

Cutout Height

10-1/4” (26.0 cm)

Gas 

Natural:

standard residential 1/2” (1.3 cm) ID gas service line.

Requirements

LP/Propane:

equipped with high capacity hose/regulator assembly for
connection to standard 5gal, 20 lb. LP/Propane gas cylinder
with Type 1, QCC-1 connection or standard residential 1/2”
(1.3 cm) ID gas service line.

Infrared Burner

21,500 BTU Nat./20,000 BTU LP 

Rating

(6.3 kW Nat./5.9 kW LP)                                

Approximate Shipping

55 lbs. (24.8 kg)

160 lbs. (72.0 kg)

Weight

F

FLLA

AM

ME

E  H

HE

EIIG

GH

HT

T

T

Trru

uS

Se

eaarr  B

BU

UR

RN

NE

ER

R

1/4”

(.64 cm)

B

BU

UR

RN

NE

ER

R  A

AD

DJJU

US

ST

TM

ME

EN

NT

T

Orifice

There is no burner adjustment for the infrared burner.  Once heated, the flames should glow a bright red color.

Summary of Contents for TruSear VGIB151T

Page 1: ...Viking Use Installation Guide Outdoor Built In TruSearTM Infrared Griller Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA ...

Page 2: ...ve all local and national codes and ordinances The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference Installation must conform with local codes or in the absence of codes the National Fuel Gas Code ANSI Z223 1 I In n C Ca an na ad da a Installation must be in accordance with the current CAN CGA B149 1 Natural Gas and Pr...

Page 3: ...e testing of that system at test pressures in excess of 1 2 PSIG 3 5 kPa The unit must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of that system at test pressures equal to or less than 1 2 psi 3 5 kPa B BA AS SI IC C S SP PE EC CI IF FI IC CA AT TI IO ON NS S D De es sc cr ri ip pt ti io on n V VG GI IB B1 15 51 1T T V ...

Page 4: ...egulator arrow points in the direction of the gas flow towards the unit and away from the supply Attach the regulator assembly to the grill unit by pulling back the female coupler sleeve towards the regulator Insert the coupler into the male coupler fitting on the grill until the sleeve snaps forward securing the connection D DO O N NO OT T f fo or rg ge et t t to o p pl la ac ce e t th he e i in ...

Page 5: ... flexible gas line attach with a 3 8 female flare adapter to the 3 8 male flare adapter to the regulator assembly Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply Attach the regulator assembly to the grill unit with the 3 8 female flare adapter on the regulator assembly to the 3 8 male flare adapter on the grill D DO O N NO OT T f fo...

Page 6: ... s se ea al la an nt t u us se ed d m mu us st t b be e a an n a ap pp pr ro ov ve ed d t ty yp pe e a an nd d b be e r re es si is st ti iv ve e t to o t th he e a ac ct ti io on ns s o of f L LP P P Pr ro op pa an ne e g ga as s 3 8 flare adapter Type 1 QCC 1 connector 3 8 flare coupling L LP P P PR RO OP PA AN NE E T TA AN NK K R RE EQ QU UI IR RE EM ME EN NT TS S A dented or rusty LP Propane t...

Page 7: ...esent 7 Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part recommended by the manufacturer Do not attempt to repair the cylinder valve if it should become damaged The cylinder must be replaced 8 If you are unable to stop a leak shut off the gas supply at the cylinder valve Remove the cylinder from the grill Call an authorized gas appliance service tec...

Page 8: ... counter space 3 When determining a suitable location for the unit take into account concerns such as exposure to wind proximity to traffic paths and keeping gas supply lines as short as possible Locate only in a well ventilated area Never locate in a building garage breezeway shed or other such enclosed areas I IM MP PO OR RT TA AN NT T G Ga as s f fi it tt ti in ng gs s r re eg gu ul la at to or...

Page 9: ...lified installer should carry out the following checks All internal packaging removed Specified clearances maintained to combustible materials Pressure regulator connected and set Manual shut off valve installed and accessible Check air shutter adjustment sharp blue flame no yellow tipping Check for gas leaks odors at all gas connections Each burner lights satisfactory individually or with adjacen...

Page 10: ... ly y v va al lv ve e a an nd d c ch he ec ck k t th he e c co on nn ne ec ct ti io on ns s f fo or r g ga as s l le ea ak ks s b be ef fo or re e e ea ac ch h u us se e CAUTION T To o l li ig gh ht t T Tr ru uS Se ea ar r i in nf fr ra ar re ed d g gr ri il ll le er r Before lighting the burner remove the stainless steel cover Push in turn the TruSear infrared control knob until the High position...

Page 11: ... ve er re ed d w wi it th h t th he e p pr ro ov vi id de ed d s st ta ai in nl le es ss s s st te ee el l c co ov ve er r f fo or r p pr ro ot te ec ct ti io on n f fr ro om m o ou ut ts si id de e e el le em me en nt ts s s su uc ch h a as s r ra ai in n F FO OO OD D W WE EI IG GH HT T O OR R C CO ON NT TR RO OL L S SU UG GG GE ES ST TE ED D T TH HI IC CK KN NE ES SS S S SE ET TT TI IN NG G C CO...

Page 12: ...ese small amounts of surface rust can easily be removed by applying Soft Scrub Gel to a damp sponge and wiping with the stainless steel grain It is important to make sure you wipe with the grain for the most efficient removal of surface rust S St ta ai in nl le es ss s S St te ee el l P Pa ar rt ts s Some stainless steel parts may have a plastic protective wrap which must be peeled off Do not expo...

Page 13: ...lems contact Viking at 888 845 4641 or write to V VI IK KI IN NG G P PR RE EF FE ER RR RE ED D S SE ER RV VI IC CE E 111 Front Street Greenwood Mississippi 38930 USA R Re ec co or rd d t th he e i in nf fo or rm ma at ti io on n i in nd di ic ca at te ed d b be el lo ow w Y Yo ou u w wi il ll l n ne ee ed d i it t i if f s se er rv vi ic ce e i is s e ev ve er r r re eq qu ui ir re ed d The model ...

Page 14: ...y labor shall be performed by an authorized Viking Range Corporation service agency or representative Warranty shall not apply to damage resulting from abuse accident natural disaster loss of electrical power to the product for any reason alteration improper installation improper operation or repair or service of the product by anyone other than an authorized Viking Range Corporation service agenc...

Page 15: ...15 ...

Page 16: ...330D PS0606VR VIKING RANGE CORPORATION 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For more product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com ...

Reviews: