Summary of Contents for VGIB242TNSS

Page 1: ...Viking Use Installation Guide Outdoor Builtoln TruSear _MInfrared Griller VMr g g _ _ po_atior 1 1 1 Fron_ S_reet G_eenwood Miss _sippi 38 _0 USA ...

Page 2: ...s Goods Gas Manifold Pressure Natural gas 4 0 W C R LP Propane 10 0 W C R If the following instructions are not followed exactly a fire causing death or serious injury may occur Do not store a spare LP gas cylinder under or near this appliance Never fill the cylinder beyond 80 percent full Ifyou smell gas 1 Shut off gas to the appliance 2 Extinguishany open flame 3 Open lid 4 Ifodor continues keep...

Page 3: ...plied parts must conform to local codes or in the absence of local codes with the National electrical Code ANSI NFPA 70 and the National Fuel Code ANSI Z223 1 In Canada Installation must be in accordance with the current CAN CGA B149 1 Natural Gas Installation Code or CAN CGA B149 2 Propane Installation Code and or local codes All pipe sealants must be an approved type and resistant to the actions...

Page 4: ... the 1 2 1 3 cm male flare adapter on the regulator assembly Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply Attach the regulator assembly to the grill unit by pulling back the female coupler sleeve towards the regulator Insert the coupler into the male coupler fitting on the grill until the sleeve snaps forward securing the connect...

Page 5: ...ed regulator assembly to the incoming flexible gas line attach with a 3 8 female flare adapter to the 3 8 male flare adapter to the regulator assembly Ensure that the regulator arrow points in the direction of the gas flow towards the unit and away from the supply Attach the regulator assembly to the grill unit with the 3 8 female flare adapter on the regulator assembly to the 3 8 male flare adapt...

Page 6: ...be an approved type and be resistive to the actions of LP Propane gas O 3 8 f Iare f _ _ adapter 3 8 flare coupling Type 1 QCC 1 connector Tank must be mounted in vertical position for proper ventilation LP PROPANE TAN K REQUIREMENTS A dented or rusty LP Propane tank may be hazardous and should be checked by your tank supplier Never use a cylinder with a damaged valve All tanks should be equipped ...

Page 7: ...valve knob counter clockwise one turn to open 6 Blowing bubbles in the soap solution indicates that a leak is present 7 Stop a leak by tightening the loose joint or by replacing the faulty part with a replacement part recommended by the manufacturer Do not attempt to repair the cylinder valve if it should become damaged The cylinder must be replaced 8 If you are unable to stop a leak shut off the ...

Page 8: ... for counter space 3 When determining a suitable location for the unit take into account concerns such as exposure to wind proximity to traffic paths and keeping gas supply lines as short as possible Locate only in a well ventilated area Never locate in a building garage breezeway shed or other such enclosed areas IMPORTANT Gas fittings regulator and installer supplied shut off valve must be easil...

Page 9: ...out the following checks All internal packaging removed Specified clearances maintained to combustible materials Pressure regulator connected and set Manual shut off valve installed and accessible Check air shutter adjustment sharp blue flame no yellow tipping Check for gas leaks odors at all gas connections Each burner lights satisfactory individually or with adjacent burners lit Any adjustments ...

Page 10: ...nnections for gas leaks before each use To light TruSearinfrared grillec Before lighting the burner remove the stainlesssteel cover Pushin turn the TruBearinfrared control knob until the High position on the knob aligns with the indicator lineon the control panel and continue to hold the knob in Pressthe electronic ignition button which corresponds to the control knob You will hear a clicking soun...

Page 11: ... When theTruSear infrared griller isnotin use itmust becovered with theprovided stainless steel cover forprotection fromoutside elements such asrain TruSear Infrared Cooking Chart FOOD WEIGHT OR CONTROL THICKNESS SETTING Chicken Breast Bnls Hamburger 1 2 3 4 thick Steaks Ribeye 1 1 2 thick Steaks Filet 1 thick HI Reduce to medium setting halfway between Hi and LO HI HI HI SUGGESTED COOKING TIME 2 ...

Page 12: ... Wipe up any debris that may have collected in the drip tray with a hot soapy towel Dry and replace drip tray pans before next use REPLACEMENT PARTS Only authorized replacement parts may be used in performing service on the side burners Do not repair or replace any part of the outdoor grill unless specifically recommended in the manual All other servicing should be referred to a qualified technici...

Page 13: ...ou are unable to obtain the name of an authorized service agency or if you continue to have service problems contact Viking at 888 845 4641 or write to VIKING PREFERREDSERVICE 111 Front Street Greenwood Mississippi 38930 USA Record the information indicated below You will need it if service is ever required The model and serial number for your grill is located on an identification plate located un...

Page 14: ...om abuse accident natural disaster loss of electrical power to the product for any reason alteration improper installation improper operation or repair or service of the product by anyone other than an authorized Viking Range Corporation service agency or representative This warranty does not apply to commercial usage Warrantor is not responsible for consequential or incidental damage whether aris...