LP/PROPANE FIXED PIPING CONNECTION

Connection:  

Standard Residential 1/2” ID gas service line - 1/2” NPT male with 3/8” flare adapter.

Operating Pressure:

10.0” W.C.P. Nat. 

Supply Pressure:

11” to 14” W.C.P. Nat. If in excess of 14” W.C.P., a step-down regulator is required.

Check with your local gas utility company or with local codes for instructions on installing gas supply lines.  Be sure to check on
type and size of run and how deep to bury the lines.  If the gas line is too small, the unit will not function properly.

To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 3/8” female flare adaptor to the
3/8” male flare adaptor to the regulator assembly.  Ensure that the regulator arrow points in the direction of the gas flow
towards the unit and away from the supply.  Attach the regulator assembly to the unit with the 3/8” female flare adapter on the
regulator assembly to the 3/8” male flare adaptor on the unit.
DO NOT forget to place the installer supplied gas valve in an accessible location.

NATURAL FIXED PIPING CONNECTION

Connection:  

Standard Residential 1/2” ID gas service line - 1/2” NPT male with 1/2” flare adapter.

Operating Pressure:

4.0” W.C.P. Nat. 

Supply Pressure:

6” to 14” W.C.P. Nat. If in excess of 14” W.C.P., a step-down regulator is required.

Check with your local gas utility company or with local codes for instructions on installing gas supply lines.  Be sure to check on
type and size of run and how deep to bury the lines.  If the gas line is too small, the unit will not function properly.

To connect the supplied regulator assembly to the incoming flexible gas line, attach with a 1/2” (1.3 cm) female flare adaptor
to the 1/2” (1.3 cm) male flare adaptor on the regulator assembly.  Ensure that the regulator arrow points in the direction of the
gas flow towards the unit and away from the supply.  Attach the regulator assembly to the unit by pulling back the female
coupler sleeve towards the regulator.  Insert the coupler into the male coupler fitting on the grill until the sleeve snaps forward
securing the connection.  DO NOT forget to place the installer supplied gas valve in an accessible location.

NOTE:  If using a Viking GSH12 flexible hose,  remove the 3/8” flare adapter and attach hose to the  the 1/2” (1.3 cm) male

flare on the regulator assembly.

5

4

Summary of Contents for VGSB5152

Page 1: ...nt Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com F20921 EN 000000 Viking Installation Guide Outdoor 15 Wide Double Side Burners ...

Page 2: ...can cause death or serious illness and which are known to cause cancer birth defects or other reproductive harm For example benzene is a chemical which is part of the gas supplied to the cooking product It is consumed in the flame during combustion However exposure to a small amount of benzene is possible if a gas leak occurs Formaldehyde and soot are by products of incomplete combustion Properly ...

Page 3: ...are adapter on the regulator assembly to the 3 8 male flare adaptor on the unit DO NOT forget to place the installer supplied gas valve in an accessible location NATURAL FIXED PIPING CONNECTION Connection Standard Residential 1 2 ID gas service line 1 2 NPT male with 1 2 flare adapter Operating Pressure 4 0 W C P Nat Supply Pressure 6 to 14 W C P Nat If in excess of 14 W C P a step down regulator ...

Page 4: ... force equal to the weight of the tank without tipping over The tank can not tip over or deflect more than 1 00 inch when a 38 lb horizontal force is applied to a 20 lb LP Propane tank Connection 1 2 1 3 cm NPT male with a 3 8 95 flare adapter Operating Pressure 10 0 W C P To connect to LP Propane regulator hose assembly Although the flow of gas is stopped when the quick disconnect system is disco...

Page 5: ...nt concerns such as exposure to wind proximity to traffic paths and keeping gas supply lines as short as possible Locate only in a well ventilated area Never locate in a building garage breezeway shed or other such enclosed areas 4 In a built in construction where an LP Propane tank is going to be used there MUST be some type of support braces cut out etc to prevent tank from moving within the ins...

Page 6: ... of air to the burner Once adjusted turn the burner off tighten the set screw on the air shutter replace the valve panel for the side burners and the grate support burner bowls and grates for the side burners To ensure proper installation of the side burners slide opening in air shutters over the orifice located in the front of the unit 11 Air Shutters Orifice 1 3 8 cm 3 8 95 cm FLAME HEIGHT 1 At ...

Page 7: ...buildup occurs do not use steel wool abrasive cloths cleansers or powders If it is necessary to scrape stainless steel to remove encrusted materials soak with hot wet cloths to loosen the material then use a wool or nylon scraper Do not use a metal knife spatula or any other material tool to scrape stainless steel Scratches are almost impossible to remove REPLACEMENT PARTS Only authorized replacem...

Page 8: ...Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you Owner shall be responsible for proper installation providing normal care and maintenance providing proof of purchase upon request and making the appliance reasonably accessible for service If the product or one of its component parts contains ...

Page 9: ...17 16 ...

Reviews: