43
Sensors are out of sync
The temperature sensors MAY be out of sync by 2°F or 3°F. Call for Service.
Sensors are out of sync -Call for service*
The temperature sensors ARE out of sync. The fault above has been established for at least 1 hour. Call for Service.
Sensor A Fault, Senor B Fault – Sensor A, Sensor B
A temperature sensor or sensor circuit has failed. Call for Service.
Miscellaneous Messages
Communications error
The control panel is not receiving communication from the System. Call for Service.
Test software installed
The Control System is operating with test software. Call for Service.
°F or °C is replaced by °T
The Control System is in Test Mode. Call for Service.
* This message can be reset from the control panel.
System-Related Messages
Program memory failure*
At Power-Up, the system has failed the Program Checksum Test. This indicates a problem with the firmware (operation program) and
requires a service call.
The settings have been reset (Persistent Memory Error)*
Contact your dealer or service organization if this message appears on more than one powerup.
The clock has failed*
Contact your dealer or service organization.
Configuration error (Spa will not Start Up)
Contact your dealer or service organization.
A pump may be stuck on
Water may be overheated. POWER DOWN THE SPA. DO NOT ENTER THE WATER. Contact your dealer or service
organization.
Hot fault
A Pump Appears to have been Stuck ON when spa was last powered. POWER DOWN THE SPA. DO
NOT ENTER THE WATER. Contact your dealer or service organization.
*This message can be reset from the control panel.
Reminder Messages
General maintenance helps.
Reminder Messages are suppressed from the factory, but can be activated in the settings by using the Preferences Menu. See Page 14.
Clean the filter
May appear on a regular schedule, i.e. every 30 days. Clean the filter media as instructed in the owner’s manual. See Filter
Maintenance.
Test the RCD
Will appear every 65 days.
The RCD is an important safety device and must be tested on a regular basis to verify its reliability.
A RCD will have a TEST and RESET button on it that allows a user to verify proper function.
DISPLAY MESSAGES & ERROR MESSAGES