35
Installation & Calibration
during the calibration process. To prevent
damage to the actuators, do not connect the
yellow power cable or the gray position
transmitter cable until instructed to do so
later on.
6.
Open the plastic cover of the capacity
motor by removing the four #10 screws.
Caution: there are wires attached to the
connector on the plastic cover. Handling
the cover too aggressively could break
the wires.
7.
Gently lift the cover and tilt it toward the
Turck connectors. Raise the cover enough
to be able to press the blue calibrate button
and be able to see the red LED on the top
of assembly.
8.
Press “Menu” on the main screen and then
press the “Slide Calibration” button, to
enter the slide calibration screen. (Note:
you must be in this slide calibration screen
before attaching the yellow power cable or
gray position transmitter cable.)
9.
Now connect the yellow power cable and
the gray position transmitter cable to the
actuator.
10. Press INC and DEC to move the slide
valve and check for the correct rotation.
See Table 1on page 48 for Actuator/
command shaft rotation specifications.
11. Note: If the increase and decrease buttons
do not correspond to increase or decrease
shaft rotation, swap the blue and brown
wires of the “yellow power cable”. This
will reverse the rotation of the actuator/
command shaft.
12. Quickly press and release the blue push
button on the actuator one time. This
places the actuator in calibration mode.
The red LED will begin flashing rapidly.
13. Note: When the actuator is in calibration
mode, it outputs 0V when the actuator is
running and 5V when it is still. Thus, as
stated earlier, the actuator voltage will
fluctuate during calibration. After the
actuator has been calibrated, 0V output
will correspond to the minimum position
and 5V to the maximum position.
14. Note: The “Slide calibration” screen on
the Vission/Vantage has a “Current”
window, which displays twice the actuator
output voltage. This value, (the % volume
and the % capacity) displayed in the
“Current Vol” and Current Cap” Windows
are meaningless until calibration has been
completed.
15. Use the DEC button on the Vission/
Vantage panel to drive the slide valve to its
minimum “mechanical stop” position.
Do
not continue to run the actuator in this
direction after the slide valve has
reached the stop. Doing so may cause
damage to the actuator or the slide
valve.
When the slide has reached the
mechanical stop position, use the INC
button to pulse the actuator to where the
slide is just off of the mechanical stop and
there is no tension on the motor shaft.
16. Quickly press and release the blue button
on the actuator again. The red LED will
now flash at a slower rate, indication that
the minimum slide valve position (0V
position) has been set.
17. Use the INC button on the Vission/Vantage
panel to drive the slide to its maximum
“mechanical stop” position.
Do not
continue to run the actuator in this
direction after the slide valve has
reached the stop. Doing so may cause
damage to the actuator or the slide
valve.
When the slide valve has reached
the mechanical stop position, use the DEC
button to pulse the actuator to where the
slide is just off of its mechanical stop and
there is no tension on the motor shaft.
18. Quickly press and release the blue button
on the actuator one more time. The red
LED will stop flashing. The actuator is
Summary of Contents for VSM 71-701
Page 1: ...1 VPN 35391S February 2006 Rev 05 Price 60 00...
Page 2: ...2...
Page 20: ...20...
Page 52: ...53 Pre Start Up Check List...
Page 99: ...99 Recommended Spare Parts List...
Page 104: ...104 Gate Rotor...
Page 110: ...110 Main Rotor VSS...
Page 112: ...112 Main Rotor VSR...
Page 114: ...114 Slide Valve Cross Shafts and End Plate...
Page 118: ...118 Capacity Slide Volume Slide Carriage Assembly Slide Valve Carriage Assembly...
Page 134: ...134 Miscellaneous Frame Components VSS Screw Compressor VSR Mini Screw Compressor...
Page 138: ...138 C FlangeAdapter Components 630 620 610 640 601 641 630 601 620 610 640 641 642 650 651...
Page 140: ...140 Replacement Parts Tools...
Page 144: ...144 GaterotorAssembly...
Page 148: ...148 Main Rotor Slide Valve Cross Shafts and End Plate Models 71 401 Only Counter clockwise...
Page 152: ...152 Main Rotor Slide Valve Cross Shafts and End Plate Model 501 701 Only Clockwise...
Page 154: ...154 Volume Ratio Capacity Slide Carriage Assembly Slide Valve Carriage Assembly...
Page 158: ...158 Miscellaneous Frame Components Model VSM 501 701 Model VSM 71 401...
Page 160: ...160 Replacement Parts Accessories Housing Accessories C Flange Assembly...
Page 166: ...166 Haight Pumps...
Page 170: ...3 Refrigerating Specialties Division...
Page 236: ......
Page 237: ......
Page 238: ......
Page 243: ......
Page 244: ...168...