40
•
TCP – for data transfer;
•
UDP – for data transfer;
•
ICMP – for connection quality testing.
To prepare data logger for connection over Ethernet, you neet to setup IP address (DHCP is not
used, because to establish connection with right data logger, server always need to know static
address of data logger). To setup connection, in Communication>Ethernet enter basic data (IP
address, Gateway IP and Subnet mask), by pressing “Set” write data to data logger and Restart
data logger (see chapter
7.12
Restarting).
Pic 29
Setup Ethernet interface [Communication > Ethernet]
For security reasons IP filter is installed (data logger support up to 5 exceptions). Enable IP filter
and add at least one IP address in list of exceptions. After you „Set“ changes, device will not