background image

NT-50907501-KUBAIR-F400-AN-210312

 9/28 

ENGLISH

KUBAIR

®

 F400 MV

with vertical axis motor

TCDZ05*

TCDZ03

TCDZ03

SIL

TCDZ 04

TCDZ 07

TCDZ 02

TCDZ 09

or

or

or

or

Optional accessory according to selection.

TCDZ08

Summary of Contents for KUBAIR F400

Page 1: ...F400 AN 210312 INSTRUCTION MANUAL INSTALLATION WIRING COMMISSIONING MAINTENANCE AFNOR CERTIFICATION ISO 14001 Environnement AFNOR CERTIFICATION ISO 9001 Q u a l i t é KUBAIR F400 Smoke extract unit F400 120 400 C 120 min ...

Page 2: ...sing assembly 17 4 ELECTRICAL CONNECTION 18 4 1 Preliminary precautions 18 4 2 Technical Characteristics 18 4 3 Wiring of versions without INTZ safety switch 20 4 4 Wiring of versions with INTZ safety switch 21 4 5 Wiring of PILOTAIR control panel French regulation 23 4 6 Electrical connection of pressure switch 23 5 START UP 24 6 MAINTENANCE 24 6 1 Maintenance periodicity 24 6 2 Spare parts KUBAI...

Page 3: ...o corrosive chemical agents 1 2 Safety instructions Wear appropriate IPE Individual Protection Equipment before any intervention Before installing the smoke extract unit make sure that the support and placement are sufficiently resistant to withstand the unit s weight and that of the accessories Do not open the access doors without first switching off the electrical power supply with the padloc ka...

Page 4: ...400 C 120 min KUBAIR F400 CC complete unit with multi directional suction plenum with horizontal or vertical axis motor KUBAIR F400 MV single ventilation unit with horizontal or vertical axis motor 8 sizes 355 400 450 500 560 630 710 800 Flow of 500 to 23 000 m3 h Construction Removable galvanised steel sheet panels Modular structure with aluminium frame Connection by 2 KUBZ 12 smooth flanges whic...

Page 5: ...C C D E EC F G GC H J K KC L 355 627 695 327 645 263 559 606 790 660 31 50 315 102 677 954 321 400 699 767 361 678 297 631 606 864 732 31 50 349 102 711 1022 321 450 779 847 392 738 326 711 606 990 812 31 50 378 102 743 1081 321 500 858 925 424 784 338 768 700 1039 890 42 62 402 112 805 1145 351 560 954 1021 441 817 354 864 700 1139 986 42 62 419 112 822 1178 351 630 1066 1133 488 912 403 977 700 ...

Page 6: ...5 39 42 59 65 560 0 75 0 37 113 120 161 175 400 0 55 49 53 72 80 630 1 1 0 55 120 125 164 182 450 1 1 67 72 92 102 710 3 0 75 146 155 266 290 500 1 5 88 94 114 126 800 4 1 1 226 238 309 337 560 2 2 111 118 159 173 MOTOR 2 SPEEDS TRI BOB DAHL 4 8 P MOTOR 1 SPEED 3 PHASES 6 POLES 355 0 6 0 15 41 44 61 67 355 0 18 39 42 59 65 400 0 6 0 15 51 55 74 82 400 0 37 49 53 72 80 450 1 2 0 3 69 74 94 104 450 ...

Page 7: ...7 28 ENGLISH 3 2 Summary charts of assembly and accessories KUBAIR F400 CC MSDZ KUBZ 04 straight MSCZ KUBZ 12 KUBZ 06 KUBZ 02 KUBZ 08 KUBZ 10 KUBZ 12 KUBZ 17 KUBZ 06 KUBZ 15 CC KUBZ 01 CC KUBZ 16 KUBZ 12 KUBZ 07 KUBZ 10 KUBZ 04 straight ...

Page 8: ...V KUBZ 08 KUBZ 10 KUBZ 17 KUBZ 12 KUBZ 03 KUBZ 11 KUBZ 12 KUBZ 08 KUBZ 03 KUBZ 06 KUBZ 03 KUBZ 15 MV KUBZ 01 MV KUBZ 16 KUBZ 10 KUBZ 07 The TCDZ accessories on the diagram below can be used with the KUBAIR F400 MV with a vertical axis motor example opposite side ...

Page 9: ...T 50907501 KUBAIR F400 AN 210312 9 28 ENGLISH KUBAIR F400 MV with vertical axis motor TCDZ05 TCDZ03 TCDZ03 SIL TCDZ 04 TCDZ 07 TCDZ 02 TCDZ 09 or or or or Optional accessory according to selection TCDZ08 ...

Page 10: ...e vertical wall of the motor cowl Mounting holes are provided so that it can be re assembled using the self drilling screws A B Connecting flange This connecting flange is attached to the smooth flange at its 4 corners for the purpose of attaching a duct A A ØF Circular connection to the MV suction horizontal motor axis This connection is used with the KUBAIR F400 MV for a duct connection which do...

Page 11: ...ivery and suction Other smooth flanges can be supplied and mounted A B B A C Covering necessary for external use horizontal axis motor Assembly of the cover the cover is attached with 4 MV version or 8 CC version 4 8 x 12 self drilling screws which are supplied J A B Over pressure flaps to be mounted on the discharge side for horizontal shaft motor Ensures good water and air tightnass when the uni...

Page 12: ... Pstat Pa 76 4 pôles 41 6 pôles 8 pôles 8 pôles 41 44 35 26 29 41 77 80 65 61 61 68 67 Qv m3 h 42 6 pôles Plage d utilisation KUBZ10 71 4 pôles 26 KUBZ 10 airflow adjustment range 8 poles 8 poles 6 poles 6 poles 4 poles 4 poles MSDZ MSCZ KUBZ 02 to 08 KUBZ 10 12 16 and 17 Weight kg Model A B C D E ØF H J K KUBZ 01 KUBZ 03 KUBZ 04 KUBZ 06 KUBZ 07 KUBZ 08 355 559 263 197 194 160 400 670 80 224 7 0 2...

Page 13: ... 72 64 63 71 62 47 30 41 39 32 31 47 Plage d utilisation KUBZ10 40 KUBZ 10 airflow adjustment range 8 poles 6 poles 8 poles 12 poles 12 poles 6 poles KUBAIR F400 MV 710 KUBAIR F400 MV 800 0 400 800 1200 1600 2000 2400 2800 3200 0 100 200 300 400 500 600 700 800 0 5000 10000 15000 20000 Pabs W Pstat Pa Qv m3 h 6 pôles 6 pôles 54 8 pôles 12 pôles 8 pôles 12 pôles 54 48 39 39 40 83 84 78 76 76 67 67 ...

Page 14: ...3 40 37 34 38 49 32 47 78 83 75 72 68 67 73 82 Plage d utilisation KUBZ10 4 pôles 4 poles KUBZ 10 airflow adjustment range 4 poles 6 poles 8 poles 8 poles 6 poles Plage d utilisation KUBZ10 0 300 600 900 1200 1500 1800 0 100 200 300 400 500 600 0 2000 4000 6000 8000 10000 12000 Pabs W Pstat Pa Qv m3 h 6 pôles 6 pôles 49 82 8 pôles 12 pôles 8 pôles 12 pôles 45 44 38 39 43 34 30 29 78 77 70 76 67 63...

Page 15: ...Straight inclined and acoustic upstand According to DTU 43 1 it is possible to attach a TCDZ 03 energy saving component or a TCDZ 05 excluding TCDZ 09 adapter plate which is placed inside the upstand For any casing with an acoustic straight upstand TCDZ 09 Take into account 80Pa pressure drop E G 150 100 100 α 100 G N E R E G N 800 100 G E ØD T TCDZ 05 Adapter plate The adapter plate allows to con...

Page 16: ... 500 4 0 6 0 400 450 500 560 3 6 3 1 2 5 1 7 37 0 560 630 4 5 8 0 450 500 560 630 5 1 4 5 3 7 2 7 45 0 710 800 6 0 11 0 560 630 710 11 8 10 3 8 3 65 0 Accessory TCDZ 04 TCDZ 07 30 TCDZ 09 TCDZ 08 Size R Weight Kg Weight Kg Weight Kg Weight Kg 355 400 300 500 700 11 0 15 5 20 0 11 2 34 0 6 2 450 500 300 500 700 13 5 19 0 25 0 14 8 51 0 10 5 560 630 300 500 700 20 5 29 5 38 0 24 2 65 5 12 2 710 800 ...

Page 17: ...material not supplied is recommended between the support surface and the base of the casing A maximum incline of 2 5 is tolerated between the motor axis and the vertical axis see diagram below 2 5 Make sure that the support is adapted to the weight of the whole machine and its various accessories Attach the casing at the Ø20 holes provided for this purpose You are advised to use a LL washer Any sc...

Page 18: ...el Rated P kW Nom I A 230V Id In Start up time s Circuit breaker 230V VARZ voltage variator VAPZ coordinated voltage variator SINGLE PHASE MOTOR WITH 1 SPEED AND 4 POLES 355 0 25 2 5 2 7 4 DIJZ 05 4 VARZ 3A200 VAPZ 3A200 400 0 55 3 9 3 2 3 DIJZ 05 4 VARZ 6A200 VAPZ 5A200 SINGLE PHASE MOTOR WITH 1 SPEED AND 6 POLES 355 0 18 1 6 1 8 3 DIJZ 05 2 5 VARZ 3A200 VAPZ 3A200 400 0 25 2 3 2 0 2 DIJZ 05 2 5 ...

Page 19: ...1 49 4 1 4 0 37 0 55 0 55 0 37 500 0 55 IE3 2 52 1 45 4 8 4 0 37 0 55 0 55 0 37 560 0 75 IE2 3 39 1 95 4 5 5 0 55 0 75 0 55 0 55 560 0 75 IE3 3 36 1 93 5 2 5 0 55 0 75 0 55 0 55 630 1 1 IE2 4 83 2 78 4 7 5 1 1 1 1 1 1 1 1 630 1 1 IE3 4 68 2 69 4 9 5 1 1 1 1 1 1 0 75 710 3 0 IE2 12 7 7 30 5 7 6 4 0 3 0 710 3 0 IE3 12 0 6 91 6 0 6 4 0 3 0 800 4 0 IE2 16 5 9 46 6 0 7 5 5 800 4 0 IE3 15 6 8 99 6 5 7 5...

Page 20: ...4 2 63 5 8 5 1 6 4 DEMZ BI 3 1 4 2 710 3 0 75 8 04 3 78 6 6 5 5 7 800 4 1 1 16 2 4 45 6 5 5 5 9 THREE PHASE MOTOR WITH 2 SPEEDS DAHLANDER WINDINGS 4 8 POLES 355 0 6 0 15 1 82 0 81 5 5 3 1 1 1 DEMZ DA 1 2 3 400 0 6 0 15 1 82 0 81 5 5 3 1 2 2 DEMZ DA 1 2 3 450 1 2 0 3 2 92 1 29 5 5 3 1 3 3 DEMZ DA 1 3 3 1 500 1 6 0 4 3 85 1 45 5 7 3 2 3 3 DEMZ DA 1 7 4 2 560 2 2 0 55 4 84 2 00 6 9 3 5 3 3 DEMZ DA 2 ...

Page 21: ...vered already assembled and wired in the factory Comment the safety switch is dimensioned for use in smoke extraction for a 400 V three phase or 230 V single phase network connection 4 4 1 KUBAIR F400 wiring with 1 speed and with INTZ 1V15 safety switch U2 Z1 Z1 U1 PE N Ph 3 7 1 5 2 6 1 3 5 7 2 4 6 8 1 phase inlet 1S 230Vac 50Hz 1 phase motor 230V L1 L2 L3 1 3 5 7 2 4 6 8 W1 V1 U1 PE V2 U2 W2 3 7 ...

Page 22: ... 1S 400Vac 50Hz Three phases motor 1S Y230 D400 V 4 4 4 KUBAIR F400 wiring with 2 speeds and with INTZ 2V15 safety switch LS inlet 400Vac 50Hz HS inlet 400Vac 50Hz Three phases 2S 400V 4 4 5 KUBAIR F400 wiring with 2 speeds and with INTZ 2V22 or INTZ 2V29 safety switch LS inlet 400Vac 50Hz HS inlet 400Vac 50Hz Three phases 400V motor 2S ...

Page 23: ...he ventilation failure 88 57 40 Ø80 110 P g 1 1 Ø 5 5 Cote de fixation A pressure switch is attached outside of the casing Connection by a cable with a cross section of 0 75 mm is advised Access to terminals and for adjustment Slightly raise and then remove the lid of the base Flashing light for the ventilation failure Flashing light for normal operating mode Power supply compliant with NF C 15 10...

Page 24: ...ice How to change the operating modes Then hand over to the user with the technical instructions for use of the casing and assembled accessories control panel etc so that they can be accessed at all times 6 MAINTENANCE The maintenance frequency depends on the operating conditions If the air is dirty poor quality the duration between two visits must be shortened WARNING Before any maintenance opera...

Page 25: ...E2 1 5kW 646818 MTTE KUBAIR 500 4PT IE2 1 5kW Spare motor impeller KUBAIR F400 500 4PT IE3 1 5kW 646819 MTTE KUBAIR 500 4PT IE3 1 5kW Spare motor impeller KUBAIR F400 560 4PT IE2 2 2kW 646820 MTTE KUBAIR 560 4PT IE2 2 2kW Spare motor impeller KUBAIR F400 560 4PT IE3 2 2kW 646821 MTTE KUBAIR 560 4PT IE3 2 2kW Spare motor impeller KUBAIR F400 355 6PT IE1 0 18kW 646822 MTTE KUBAIR 355 6PT IE1 0 18kW ...

Page 26: ...646859 MTTE KUBAIR 800 8PT IE3 2 2kW Spare motor impeller KUBAIR F400 MV CC THREE PHASE 2 SPEEDS DALHANDER WINDINGS KUBAIR F400 355 4 8PT 0 60 0 15kW 646870 MTTE KUBAIR 355 4 8PT 0 60 0 15kW Spare motor impeller KUBAIR F400 400 4 8PT 0 60 0 15kW 646871 MTTE KUBAIR 400 4 8PT 0 60 0 15kW Spare motor impeller KUBAIR F400 450 4 8PT 1 20 0 30kW 646872 MTTE KUBAIR 450 4 8PT 1 20 0 30kW Spare motor impel...

Page 27: ...en boxes and other non dangerous wastes must be made reusable by an approved service provider It is strictly prohibited to burn bury or dump them in nature 7 2 Treatment of a Professional WEEE This product must not be dumped or treated with household refuse but must be deposited in an appro priate collection point for waste electrical and electronic equipment WEEE ...

Page 28: ...ly concerned about improving his equipment the manufacturer re serves the right to make all technical changes without notice VIM Les prés de Mégy Sud SOUDAN CS 60120 79401 ST MAIXENT L ECOLE CEDEX Tél 05 49 06 60 38 ou 05 49 06 60 25 Fax 05 49 06 60 36 sav vim fr www vim fr ...

Reviews: