20
• Timed switch-off
- Repeatedly press button
until the display shows OFF and, alongside the temperature value, the
OFF
symbol
blinking
- Press button
; the display will show two blinking digits indicating the number of hours (h) to set�
- Use button
to select the desired number of hours (from 1 to 99) then press button
to confirm�
The chronothermostat display shows the phase of setting the number of hours with the following indications:
- if the set number of hours is included in the current day, the chronothermostat shows the time when the
“Timed
Switch-Off”
setting ends with two segments blinking on the time printed under the display;
- If the set number of hours exceeds those of the current day (therefore moving on to the next days), the
chronothermostat will show not only the time when the
“Timed Switch-Off”
setting ends (see above), but also the
day when this setting ends; the
arrow will be shown blinking on the day printed above the display�
The chronothermostat then remains in
Off
mode for the set length of time at the end of which it returns to the previously
set operating mode�
• Antifreeze
- Repeatedly press button
until the display shows
Anti
and, alongside the set antifreeze temperature value,
the
*
symbol blinking
- Press button
to confirm� If the setting is not confirmed within approximately 40 seconds, the chronothermostat
will return to the previously set operating mode�
The Antifreeze value can be selected with the procedure for setting the temperature levels that can be activated by
pressing button
�