61
Note
: No response SMS message is required from the chronothermostat 01913�
Example�
If the set user code is the default 1234 and you want to configure the auxiliary output as one-position
stable with an activation time of 0�5 s, send the following SMS message:
1234.R1.MONO.05
13.7.4 Reading auxiliary output configuration
This function enables viewing the configuration assigned to the auxiliary output�
The SMS message to send is the following one:
<user code>.?R1
The chronothermostat will send an SMS reply message with the following format:
GSM-01913 1/1
R1
<auxiliary output customized label>
two-position stable/one-position stable:<time>s
Example�
If the set user code is the default 1234 and:
- the SMS label of the auxiliary output has been set as “staircase lights”;
- the operating mode is configured as one-position stable with an activation time of 2 s�
On sending the SMS message:
1234.?R1
The chronothermostat 01913 will send the following SMS response message:
GSM-01913 1/1
R1
staircase light
ONE-POSITION STABLE:2s