71
13.10.5 Viewing and changing auxiliary output status
This is a test function used to verify the operation of the auxiliary output and external relay connected
to it�
Important
: The auxiliary output MUST be used to control an external auxiliary relay and not to control
the load directly�
Besides viewing the state of the output, this function is also used for activation (
Act
) and deactivation
(
dIs
), for the auxiliary output test�
To verify the operation of the auxiliary output, proceed as follows:
- enter the GSM menu;
- using button select the item
GSM COnF
and press
;
- using button select the item
Out StAt
and press
;
The display (in the temperature field) shows the current state of the auxiliary output (
dIs
or
ACt
)�
Pressing button
or
exits displaying the state of the auxiliary output while with button you
access the test mode for this output; again using button you select the desired state (the state
flashes)� Finally press
to confirm or
to cancel the operation�
On accessing the auxiliary output test mode the display shows
tEST Out
�
13.10.6 Viewing and changing auxiliary output configuration parameters
This function is used to set and check the auxiliary output configuration parameters (see paragraph
13�7 on page 59); to view and edit these configuration parameters proceed as follows:
- enter the GSM menu;
- using button select the item
GSM COnF
and press
;
- using button select the item
Out COnF
and press
;
The display (in the temperature field) will show the current setting (
BI
=two-position stable or
MOn
=one-position stable)�
With button you can change this setting; with
you confirm while with
you cancel the
change made�
Confirmation of the two-position stable setting concludes the procedure for setting the auxiliary output
and you are returned to the main menu�
Confirmation of the one-position stable setting, instead, continues with the display of the output
activation time; this value is displayed in the temperature field and is included between 0�1s and 60 min�