17
•
(historical data reset): this option lets you delete ALL the historical data saved
by the energy probe; since this operation cannot be undone, an additional confirmation
screen is displayed (
YES
to delete and
NO
not to delete).
• (hourly consumption): enables you to scroll one by one through the hours prior to
the current one; the indices range from “0h” (current hourly consumption) to “-23h”
(hourly consumption of 23 hours ago).
• (daily consumption): enables you to scroll one by one through the days prior to the
current one; the indices range from “-0D” (current daily consumption) to “-30D” (daily
consumption of 30 days ago).
• (monthly consumption): enables you to scroll one by one through the months prior to
the current one; the indices range from “-1M” (monthly consumption of the last month)
to “-11M” (monthly consumption of 11 months ago).
N.B.
: Monthly consumption (or generation) is considered to be the consumption (or
generation) recorded in a fixed period of 30 days. The month “-
1M
” therefore represents
the consumption recorded in the period from 30 days ago until yesterday. The month
“
-2M
” represents the consumption recorded in the period from 60 days ago until 31
days ago, etc.
• (yearly consumption): enables you to scroll one by one through the years prior to the
current one; the indices range from “
-1Y
” (yearly consumption of the last year) to “
-3Y
”
(yearly consumption of 3 years ago).
N.B.
: Yearly consumption (or generation) is considered to be the consumption (or
generation) recorded in a fixed period of 365 days. The year “
-1Y
” therefore represents
the consumption recorded in the period from 365 days ago until yesterday. The year
“
-2Y
” represents the consumption recorded in the period from 730 days ago until 366
days ago, etc.
Confirming the selection will then display the energy consumed or generated in
Wh
or
kWh
. Obviously, if the energy probe was installed at a time when there were not yet any
data for the period of consultation, the historical energy data will be 0.
For example, if the probe was installed 20 days ago and we are consulting the term "-3
months" then the consumption is obviously 0 Wh.