23
7.6 Antifreeze
This mode, which can only be activated when the system is operating in heating mode, lets you set a
minimum temperature value ( setpoint) to avoid damage to the pipework or to keep it from falling below
a certain safety level when you are away for lengthy periods in the winter.
The "antifreeze" mode is activated directly from the Settings menu.
Once activated, antifreeze mode is identified by the
icon above the temperature indicator.
Fig. 21: Antifreeze mode
7.7 Remote reduction
Remote reduction is a useful way to "centralize" energy saving if there are multiple 02910 thermostats in
different rooms of the same house.
Example: Before going to bed, using a simple switch, all the thermostats in the house are set onto "reduc-
tion" at the same time.
This mode comes into operation when the multi-function input is activated only if this has been
suitably configured; the multifunction input is activated solely when the timer-thermostat, before
the activation, is in Manual mode (otherwise the multi-function input is ignored).
In "Remote reduction" mode, the device regulates the temperature to a value equal to Tcomfort -
; in this condition, the display and the relevant buttons must not be used (this is because the device is
controlled by remote).
The "Remote reduction" mode is identified by the
and
icons located simultaneously above the
temperature indicator.