8.10 Energy probe setting
When the energy probe is connected to the device, the menu is accessible and allows you to enable or
disable the measurement of each phase or configure the "power threshold" alarm.
There are the following submenus:
• If “
P1
” or “
P2
” or “
P3
” blink it is possible to enter the submenu for configuring phases 1, 2 and 3 of
the energy probe.
• If the
and ”
kW
” icons blink it is possible to enter the "power threshold" alarm submenu.
8.10.1 Configuring a phase to be measured
To measure the power/voltage of phases 2 and 3 (or 1 if previously disabled) you need to enable
them via this submenu and for each one of them set the calibration value of its current probe
01457.
• With
confirm the selection of “
P1
”,“
P2
”,“
P3
”, using
and
you can enable or
disable the respective phase by selecting
ON
or
OFF
and confirming with
.
• After the above setting, if the channel is enabled, the display will prompt you to enter the 3-digit
number printed on the label applied to each probe 01457 (for example, 12B); using
,
and confirming with
enter the 3 digits one at a time.
Note: If the channel (1 or 2 or 3) is disabled, the probe will ignore the voltage/power value meas-
ured by that channel; so even if physically there is a power other than 0 which runs through the
disabled phase, the probe will still display the value 0.
8.10.2 Configuring the “power threshold” alarm
The menu lets you set an overall power level (i.e. the sum of all 3 channels) read by the energy
probe and on exceeding which the timer-thermostat will emit an audible "alarm" warning. This
feature is useful to warn the user of exceeding a defined consumption threshold and give her
the chance to intervene by turning off the source of excessive consumption. This will help to
avoid potential disconnection of the residual current device or to optimize power consumption
according to need.
The alarm lasts as long as the measured power remains above the alarm level and stops when
it falls back below that level.
Confirm with
.
8.11 Buzzer (beep) setting
This menu is available only if the timer-thermostat is connected to the circuit board 02915 and the ener-
gy probe 02960 connected to it is working (vice versa the menu will not be displayed).
This menu lets you enable/disable the device's buzzer; if it is disabled there will no longer be any sound
when you touch the buttons or in cases of confirmation/error.
Whereas, in the event of an alarm, the sound signal will always be guaranteed.
Using
and
select “
ON
” or “
OFF
” and confirm with
.