3
1. Timer-Thermostat 02910
Wall-mounting, battery-powered timer-thermostat with interface with capacitive keys and equipped with
user-friendly functions to facilitate energy saving.
Designed to control heating and air-conditioning via C, NC, NO relay output.
Equipped with multi-function input for remote control (reduction, activation, summer/winter switching).
Can be connected, via circuit board 02915, to the energy probe 02960 (not supplied) for viewing consumption/
generation of electricity and corresponding historical data.
If the device is used in combination with the energy probe 02960 a built-in buzzer is available.
2. Field of application
The appliance is designed to control room temperature by acting on the control circuit of the burner or circu-
lation pump (heating) or on the control circuit of the air conditioner
(air conditioning), ensuring an ideal temperature.
The graphical user interface, thanks to special views, facilitates system management helping the user to oper-
ate while maintaining a state of energy saving.
Consultation of the energy consumption (or generation) carried out by connecting to the energy probe 02960,
lets you monitor up to 3 separate phases (with common neutral), for a maximum of 10kW per phase. The
device will not activate/deactivate loads, depending on the powers read (only monitoring with audible alarm,
if any).
3. Installation
The appliance must be installed on a wall at a height of 1.5 m off the floor in a suitable position for correctly
detecting the ambient temperature. It must not be installed in niches, behind doors and curtains or in areas
affected by sources of heat or atmospheric factors.
The timer-thermostat is a wall-mounting device that can be installed directly on a wall or on 2 and 3 module
back boxes.
It should be used in dry, dust-free places at a temperature between 0°C and +40°C.
4. Connections
4.1 Relay connection
L
N
U1
NO NC C
L
N
U1
APRE
CHIUDE
NO NC C
Circulation pumps, burners, solenoid valves
Motorized valves