39
Configuration of the video door entry unit.
All the main standard functions of the video door entry unit seen in the chapter “FUNCTIONS OF THE VIDEO
DOOR ENTRY UNIT” are configured with the buttons on the front of the device (see fig. 6); for the advanced
programming of the video door entry unit (optional functions such as setting groups, association of buttons with
specific commands, configuration of the intercom calls, association with the landing audio/video call buttons, etc.)
it is necessary to use the PC and the USB 02024 interface and the “SaveProg” software.
Configuration of the standard functions of the video door entry unit.
Configuration of the standard functions of the video door entry unit enables satisfying the application requirements
of most of the systems that are installed. According to the state of operation of the monitor (ON or OFF) it is pos-
sible to set and program different functions that are as follows.
Enabling the self-start function.
To use this function it is necessary to configure the panel so that it is enabled to receive the self-start command
(see the panel parameters in the Two Wire documentation - parameter enabled by default).
WITH THE MONITOR ON, sending the self-start command allows sequential viewing of the images sent from the
video cameras of the video panels present besides the main one (it is necessary to set the self-start sequence on
the MASTER panel with the PC and the USB 02024 interface with “SaveProg” software).
Enabling the “User Away” function.
This type of function allows the user, via the external panel, to signal his own absence to the guard room consumer
unit (if applicable); it can moreover be used also in the case in which the user is at home but doesn’t want to be
disturbed. When the function is enabled the video door entry unit that receives the call doesn't emit any audible
warning and it doesn't turn on the monitor.
Audio/video communication for landing calls.
If there is the need to install one or more indoor audio/video call stations (“landing call”), there are two different
types:
- landing calls, “audio only";
- landing calls, “audio/video”.
According to the chosen type, the installation of modules and auxiliary accessories is necessary.
Landing calls, audio only.
If there is a speech unit on the landing with only the audio function (art. 20577 or 14577), the video door entry unit
must be configured for being able to receive the audio communication from the landing call button.
To associate the landing call button with the video door entry unit carry out the following procedure:
1. Code the landing call button (see the instructions sheet of art. 20577 or 14577)
2. Associate the video door entry unit/audio door entry unit with the landing call button 20577/14577 using
the PC and the USB 02024 interface with “SaveProg” software (see the chapter “CONFIGURATION OF THE
OPTIONAL FUNCTIONS OF THE VIDEO ENTRYPHONE” - Association of the landing calls) of this manual.
NOTE: To associate the video/audio door entry unit with the landing call solely of the audio type it is necessary to
keep the call type selection jumper (set on the removable terminal side of 20577/14577) in position “A.”
Video door entry system