background image

32

Installation topology.

In practice there are different installation topologies for creating video door entry systems; the type of each system 
in fact depends on the structure of the property, the number of outdoor and indoor stations that is desired to be 
installed and the functions to be enabled. 

The most recurrent diagrams are typically those where there is one or more outdoor calling stations and one 
or more indoor answering stations. These outlines then differ according to the functions and services required 

(connection of a number of video door entry units in parallel, bell repeaters, actuators for external services, etc.) 
for which it is necessary to introduce specific supplementary modules (supplementary power supplies, external 

relays, etc.).

Examples:

TE

SE

AL

   K

2

2

2

2

21553

VV

Video door entry system

Figure 23 - Video door entry system 2 indoor stations

AL -  Power Supply Art. 02030

TE  -   Video external entrance panel Art. 02003

 

K  -  Landing call button

SE -  Electric lock 12 Vdc 

VV -  Multimedia video touch screen 21553

Summary of Contents for 21553

Page 1: ...Instructions manual 21553 Multimedia video touch screen 10in Full Flat ...

Page 2: ......

Page 3: ...NÙ 3 2 1 Notices 4 3 SETTINGS 5 3 1 General 5 3 2 Vimar Web Server IP network 12 3 3 Video door entry system 14 3 4 User Management 58 3 5 Update 65 3 6 Procedure for Installing Applications from Market Vimar Group 67 5 INSTALLATION RULES 70 4 REGULATORY COMPLIANCE 70 ...

Page 4: ...lling the entire home automation system automation intrusion detection alarm system and video door entry system but also browsing certain websites weather forecasts news RSS feed reader web radio displaying video or photographs listening to music mp3 files writing notes and linking them to an acoustic alarm signal date and time creating graphic notes with real drawings thanks to the blackboard fun...

Page 5: ...3 Main Menu 2 MAIN MENU To display all the other icons scroll horizontally with your finger over the area covering them ...

Page 6: ...the associated functions please see chap 3 4 on page 58 2 1 Notices In case of special settings or events for example video door entry call alarm silencing etc the multimedia video touch screen will display the following warnings User absent Ringtone off Door open indicator SD card not inserted SD card inserted 51 75 SD card inserted 76 100 Indicator for lost call video door entry system and new n...

Page 7: ...g the icon takes you to the Settings menu 3 1 General Touching the icon displays the following options System info Reserved System info Date and Time Language and Unit of Measurement Energy Saving Line Out Configuration Save Restore Settings ...

Page 8: ...e multimedia video touch screen Settings Date and Time By touching the icon it is possible to adjust the time and date displayed By touching the relevant icons it will be possible to select Automatic or Manual mode viewing the time in AM PM or 24h mode the time zone and set the current date ...

Page 9: ...7 Automatic Manual Settings ...

Page 10: ...measurement with which the multimedia video touch screen will display the temperature of the various system environments Touch the drop down menu on Language and select the desired one Touch the icon corresponding to the unit of measurement for the temperature in C or F the set unit of measure ment will then be used in the Weather application Settings ...

Page 11: ...o on the SD card enables viewing the current day date and time The drop down menu alongside the Screen Saver ON icon is used to set the time out at the end of which the screen saver will be displayed By selecting it is possible to set only the monitor switch off timer the display of the video touch screen will switch off The drop down menu alongside the monitor switch off timer icon is used to set...

Page 12: ...ndent sound source Touching the icon displays the icons for single or joint control of the audio channels To adjust the default volume of the speakers during a call touch the cursor of the scroll bar and move it to the left or right according to the desired volume the level is highlighted by the illumination of the bar Settings ...

Page 13: ...he screen that is used to save the configuration made or restore the one prior to the changes Then touch the icon or to carry out the desired operation When saving the configuration a pop up is displayed that allows you to choose where you want to save it Settings ...

Page 14: ...e configuration options for the network settings and for the interfacing between the multimedia video touch screen and the Vimar Web Server 01945 IP Network Parameters Configuration The network parameters can be set automatically by the device or by manually entering the addresses to be linked ...

Page 15: ...13 Vimar Web Server IP network Vimar Web Server Configuration With the icon you seek and automatically link the Web Server 01945 to the multimedia video touch screen ...

Page 16: ...960 or control pan els with video door entry unit 01956 the following applies The maximum number of indoor stations per pillar or after separator 692S made with art 21550 20550 14550 01960 01963 is 4 that is a maximum of 4 independent home automation subsys tems connected to the pillar of the Due Fili system It is possible to connect other Due Fili devices art 21553 21554 01955 20557 20577 21550 2...

Page 17: ... Description of terminals The connector on the pillar side through which all the connections from and to the video door entry unit are made has 8 terminals inputs and outputs divided according to the functions described in the table on the fol lowing page Operation of the Two Wire system The Two Wire system enables digital coding of the devices and the commands that are sent or that come from the ...

Page 18: ...nce of video signal 02022 digital relay with 2 independent contacts and maximum load of 3A 230V per contact As regards all the technical characteristics supply voltage current delivered power input description of terminals etc see the technical manuals General information on the digital controls The digital controls are packets of data that can be sent from to each digital device and contain the i...

Page 19: ...iliary relay to set up art 02022 see technical documentation art 02022 NOTE There are up to a maximum of 16 AUX SERVICES in the system Each single command is sent by pressing a button associated with the same command on the device Other commands can be associated and programmed as preferred on the available buttons via pc interface USB 02024 and EVCom software The main function of the device is to...

Page 20: ...e adapted according to the installation topology of the plant especially to assure the maximum quality of the video signal The connector TV video termination must be jumpered according to the prescriptions given in the following table position A no termination if the bus enters and exits the device position B termination 100 Ohm if the bus terminates in the device position C termination 50 Ohm alt...

Page 21: ...evices but not advanced programming this programming is anyhow enough for the operation of the devices in most systems Device programming phases For the correct configuration and programming of the system follow this procedure in sequence Install and connect all the system devices For video door entry systems set the jumper for video termination as shown on the connection diagrams If present in th...

Page 22: ...alphanumeric keyboard it is enough to key in this code and send it to the device by pressing the confirmation button on the panel while if you have a push buttons panel send the call with the button that you want to associate with the video door entry unit on the panel Lastly check that the multimedia video touch screen answers the call with an alphanumeric panel key in the set code and press the ...

Page 23: ... one that is starting from the third one By using the USB 02024 interface with PC and EVCom software it is possible to program the activation of the bell of all the video door entry units without all the monitors coming on at the same time then only the monitor of the video door entry unit being answered from is activated with the self start push button in such a way as not to have to use any addi...

Page 24: ...ff speakerphone to answer the call and communicate with the speech unit it is sufficient to touch the icon To break off the communication touch the icon again The call time is set as a panel parameter these parameters can all be set in the phase of programming the external panel MASTER and involve various functions such as timing recording users etc for a full list of the parameters please see the...

Page 25: ...er secondary panels fitted the progressive sequence is programmable as a panel parameter using the PC USB 02024 interface and the EVCom software The self start on further additional stand alone video cameras type CCTV for instance 20560 14560 20565 14565 is constrained by the presence of the audio video interface 02016 For greater details see the chapter AUDIO VIDEO INTERFACE FOR VIDEO CAMERAS in ...

Page 26: ... a sensor with a N O contact to the terminals PA and M of the panel of the Two Wire system The icon turns on when at least one of the enabled doors closes the contact on the respective panel Example of installation Video door entry system Figure 12 Connection of the door open signal with additional power supply TE Video external entrance panel Art 02003 CP Lock opening button SE Electric lock 12 V...

Page 27: ...dc and dedicated power supply The activation time can be programmed as a panel parameter see the chapter PROGRAMMING THE TWO WIRE PANEL the LOCK command is activated with both the MONITOR ON and OFF Example of installation Figure 13 Electrical Lock 12Vdc 200mA max Figure 14 Electrical Lock 15Vac 2A max AL Elvox Power Supply Art 832 030 TE Video external entrance panel Art 02003 RL Relay Art 02021 ...

Page 28: ...related actuator of the panel use the terminal 12V as positive and F1 or F2 as negative to enable an external auxiliary relay to setup For loads supplied at 230 V it is recommended to use relays of 12 Vdc with output 230 Vac 3 A The staircase lighting command is always active in both states of operation MONITOR OFF and MONITOR ON respectively Example of installation Figure 15 Staircase lighting wi...

Page 29: ...ones that have not already been used e g to switch on the stair lights or the AUX 1 2 SERVICE commands up to a max of 16 independent services and that are free from other uses with the support for an external digital relay art 02022 The command is activated by touching the appropiate icon or the combination of buttons that sends the selected command see the map of the combinations in 2ndF in chapt...

Page 30: ...ugh Finally to make the audio video call from the landing it is necessary to use the audio video interface for video cameras 02016 see the chapter AUDIO VIDEO COMMUNICATION FOR LANDING CALLS of this manual Example of installation Alimentatore Targa principale Chiamata Fuori Porta Audio Video Montante Art 02037 Art 02037 D C B A Art 02037 20577 14577 CH 1 2 E E FP A B C M 12 2 12 S 1 0 28V 1 PRI 2 ...

Page 31: ...2 Art 02032 IF Art 02016 TV A B C A V 21553 VV Loading calls Audio Video Power supply Entrance panel Pilar Figure 19 Landing calls audio video For further details on the connections see the technical documentation of the single articles call button video cameras etc and the related diagrams given therein AL1 Power Supply Art 02030 AL2 Power Supply Art 02032 IF Audio video interface for video camer...

Page 32: ... so as not to exceed the permissible delivery of the main power supply 02030 In the phase of configuration it is possible to set call groups that are groups of video door entry units that at the same time answer the same call in two different modes that can be set via advanced programming with PC and the USB 02024 interface with EVCom software for the details see chapter CONFIGURATION OF THE OPTIO...

Page 33: ...y Example of installation Cavo All Alimentatore Art 02037 CH 1 1 2 2 E E FP A B C M 12 1 2 Art 02037 Art 02037 Art 02037 CH 1 2 E E FP A B C M 12 AL2 CH 1 2 E E FP A B C M 12 PRI AL1 NT M Art 02031 Art 02030 U 21553 VV 21553 VV 21553 VV Figure 22 Video door entry units with simultaneous video calls AL1 Power Supply Art 02031 AL2 Power Supply Art 02030 M Pillar NT Network VV Multimedia video touch ...

Page 34: ...or more indoor answering stations These outlines then differ according to the functions and services required connection of a number of video door entry units in parallel bell repeaters actuators for external services etc for which it is necessary to introduce specific supplementary modules supplementary power supplies external relays etc Examples TE SE AL K 2 2 2 2 21553 VV Video door entry syste...

Page 35: ... a building complex it is necessary to insert further supplementary modules such as concentrators CC additional power supplies AL1 and AS separators SP Appartamento 1 Appartamento 2 20557 14557 TE AS AL AL SP DV DV K K VV CV CV SE 20557 14557 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 21553 VV 21553 Flat 1 Flat 2 Figure 24 Video door entry system multi family AL Power Supply Art 02030 AS Additional power Suppl...

Page 36: ...en in the attached diagrams INSTALLATION EXAMPLES AND DIAGRAMS or the Two Wire technical diagrams Examples 20577 14577 K CV CV 20577 14577 K AL2 CC AL1 AL2 SE SE TE TE 2 2 2 2 2 2 2 2 2 2 2 2 2 21553 VV Video door entry system Figure 25 Video door entry system 2 outdoor stations AL1 Power Supply Art 02030 AL2 Power Supply Art 02031 CC Relay Art 02019 TE Video external entrance panel Art 02003 K La...

Page 37: ...ry system in building complex AL Power Supply Art 02030 AS Additional power Supply Art 02032 for LED power supply CE Elvox Audio Door Entry Unit Art 6209 DV Video distributor Art 682D SP Separator Art 02020 TE Video external entrance panel Art 02003 VE Elvox Video Door Entry Unit Art 6309 6309 C 6009 6209 6145 6009 C 6200 6145 K Landing call button SE Electric lock 12 Vdc CV Audio Door Entry Unit ...

Page 38: ... User Away function This type of function allows the user via the external panel to signal his own absence to the guard room consumer unit if applicable it can moreover be used also in the case in which the user is at home but doesn t want to be disturbed When the function is enabled the video door entry unit that receives the call doesn t emit any audible warning and it doesn t turn on the monito...

Page 39: ...NTRYPHONE Association of the landing calls of this manual NOTE To associate the video audio door entry unit with the landing call of the audio video type it is necessary to keep the call type selection jumper set on the removable terminal side of 20577 14577 in position V IMPORTANT The video audio door entry unit can be associated with up to a maximum of 4 different landing call buttons the identi...

Page 40: ... Audio Door Entry Unit Art 6209 SP Separator Art 02020 TA Audio external entrance panel Art 89F3 89F4 IF Audio video interface for video cameras Art 02016 CP Landing call button Art 20577 14577 K Landing call button CV Audio Door Entry Unit Art 20557 14557 SE Electric lock 12 Vdc TC Video Camera Art 20560 20565 VV Video Door Entry Unit Art 20550 01963 Figure 28 Landing calls audio video Flat 2 Fla...

Page 41: ...ansion modules maximum 16 video cameras Whereas if the interface is not identified but only associated with the landing call button 20577 or 14577 the video cameras corresponding to the calls sent from the landing buttons maximum 4 landing calls with the related video camera can be turned on and self start is also possible on the various video cameras connected to the interface making a fictitious...

Page 42: ...face with EVCom software see the related technical documentation 1 2 U V M I A B C D PRI NT Art 02032 PA TV TV SE B2 B1 EXT EXT VLED X M PA CA M S S 12V L SR F2 F1 M T U V M I A B C D PRI NT Art 02032 T U V M I A B C D PRI NT NT Art 02032 T U V M I A B C D PRI TC TC TC TC AL AL AL AL Art 02032 T 0 28V 1 PRI 2 B1 B2 AL Art 02030 IF Art 02016 NT SP V3 MV3 MV4 A3 A4 V4 MA3 MA4 A PROGRAM EXPANSION MOD...

Page 43: ...ary to use the PC and the USB 02024 interface with EVCom software see the related technical documentation On sending the audio video call by pressing the landing nameplate button art 20577 or 14577 the interface will enable the video camera associated with it With this type of configuration it is possible to connect up to 4 video cameras for the 4 possible landing call buttons NOTE It is possible ...

Page 44: ...io door entry unit intercom call Interphone In the main window touch the icon and subsequently the icon Video door entry system The ringtone must be set by selecting the one you want from a predefined list of ringtones alternatively to these it is possible to upload mp3 files Touch the icon to set the ringtone associated with the call from the panel Touch the icon to see the list of default ringto...

Page 45: ...e selection made Touch the icon to set the ringtone associated with the intercom call Touch the icon to see the list of default ringtones and touch the one you want Touch the icon to confirm the selection made If you want to associate an mp3 file previously uploaded to the multimedia video touch screen via the USB or SHDC port with the ringtone it is sufficient to touch the icon and select the des...

Page 46: ...iated with the button for example what is controlled 4 icon associated with the button Touch the icon to confirm the selection made Video door entry system Ringtone volume adjustment The volumes of the ringtones described above are unmistakeably adjusted in a similar manner for all the types of call from external panel landing or intercom Touch the cursor of the scroll bar and move it to the left ...

Page 47: ...d The position of one button in relation to the others depends only on where it is located in the creation list this position can be changed by means of the and icons Finally the icon enables deleting the corresponding button Video door entry system ...

Page 48: ...ain window touch the icon and then the icon View the list of video cameras For each button it is necessary to set 1 ID of the panel MASTER panel panel 2 15 2 video camera index 1 16 3 text associated with the button for example the room where the video camera is installed 4 icon associated with the button Touch the icon to confirm the selection made Video door entry system ...

Page 49: ...mera The position of one button in relation to the others depends only on where it is located in the creation list this position can be changed by means of the and icons Finally the icon enables deleting the corresponding button Video door entry system ...

Page 50: ...er In the main window touch the icon and then the icon For each button it is necessary to set 1 recipient of the call ID 1 200 2 text associated with the button for example the room where the indoor station is installed 3 icon associated with the button Touch the icon to confirm the selection made Video door entry system ...

Page 51: ...ation between the speakers The position of one button in relation to the others depends only on where it is located in the creation list this position can be changed by means of the and icons Finally the icon enables deleting the corresponding button Video door entry system ...

Page 52: ...e button by setting one of the following options 1 The associated lock is that of the last call received default behaviour 2 The associated lock is the one defined in the phase of configuration In this section it must therefore be possible to enable option 2 and specify the associated ID panel1 panel15 1 200 In the main window touch the icon and then the icon Setting the operation of the icon with...

Page 53: ...ing images and sound In the main window touch the icon and then the icon Set the answer time by entering a value in the shown range Video door entry system recording is set as follows timeout starts with the call request at the end of the timeout if the user has not answered the video door entry system answering machine function is started Video door entry system ...

Page 54: ...tone disabled icon is displayed Touching the icon disables the User absent function and on the right of the title bar the User absent icon is displayed Finally at bottom right there are the following icons to view the icons associated with the intercom calls configured in the system to cyclically view the images transmitted from the video cameras each touch changes video camera to view a list of c...

Page 55: ...he LOCK or AUXILIARY SERVICE button to send the code of the called device to the calling video door entry unit The video door entry unit responds to program ming with an audible warning 2 Set the button for sending the FUNCTION F1 F2 using a device that is able to do it for instance audio video door entry units already configured panels USB 02024 interface for PC EVCom software send the FUNCTION F...

Page 56: ...ry identification code see the chapter SECONDARY NUMERICAL CODING OF THE VIDEO DOOR ENTRY UNIT of this manual that enables inserting the video door entry unit in a group of devices audio video door entry units that at the same time receive a call this association can also be made via advanced programming with USB 02024 interface for PC EVCom software There are four possible different groups G1 G2 ...

Page 57: ...strate solely the method of programming with the alphanumerical keypad on the front of the Two Wire panel for configuration with the PC see the related technical documentation To access the panel configuration menu carry out the following operations Press buttons and at the same time Enter the password to access programming key in 654321 for the first configuration default password set by the fact...

Page 58: ...00 00 Timed code enabling No First timed code No association Last timed code No association Code validity time bands No association Self start sequence Master entrance panel only No association Monitor audio door entry units configuration Monitor audio door entry units function button assignment Intercommunicating Self start Auxiliary services F1 function assignment F2 function assignment F1 funct...

Page 59: ...ing panel without a call coming from the entrance panel or landing panel respectively Intercom Optional function that permits audio communication between two indoor stations Bus Physical connection permitting the transit of the electrical signals necessary for the operation of the system gener ally both analogue audio and video and digital commands electrical signals can transit on the Bus and als...

Page 60: ...rs and editing ones already config ured Before displaying the screen for user management the multimedia video touch screen requests authentication by the administrator by entering name and password The default passwords namely the ones to use when first switching on that will then be subsequently able to be changed are the following Administrator password admin Installer password inst When creatin...

Page 61: ...ing the icon displays the screen that enables managing the three types of user Administrator Installer User The table shown on the page alongside illustrates the three types of user and the functions associated with them in the phase of creating users then it will suffice to link to each one of these the privileges that you want to assign User Management ...

Page 62: ...Out Save Restore Configuration VIMARWEBSERVERIPNETWORK IP Network Parameters configuration Vimar Web Server configuration VIDEO DOOR ENTRY Installation Ringtones Accessory Functions video cameras Intercom Door Opening Video door entry system answer ing machine USER MANAGEMENT Users Groups Permissions UPDATING Operating System Applications User Management ...

Page 63: ...cess to Calendar Application not modifiable Access to Blackboard Application not modifiable Access to Weather Application not modifiable Access to News Application not modifiable Access to Feed Reader Applica tion not modifiable Added and change Blackboard messages not modifiable Added and change Feed not modifiable Added and change News not modifiable Added and change Weather location not modifia...

Page 64: ...62 Touching changes the settings for already configured groups deletes the selected group adds a new group User Management ...

Page 65: ... shows the screen that enables assigning users with the menus and applica tions they can access Touching the icon for the user and the desired application enables this user to utilize the selected function User Management ...

Page 66: ...64 User Management ...

Page 67: ...65 3 5 UPDATE Touching the icon displays the options that enable updating the multimedia video touch screen Update ...

Page 68: ...ng the or icon displays the screens that enable downloading the firmware of the operating system and of the applications used by the multimedia video touch screen After selecting the firmware to download shown in the pop up window touch to confirm the update ...

Page 69: ...used by the end user The following procedure describes how to carry out these operations by taking the Secuviewer application as an example of reference to control the Elvox Vimar Group DVR and Elvox Vimar Group PTZ type cameras Starting from the main menu with no Secuviewer icon tap the icon and log in as Installer In the left column as the last option you will see the icon N B If the icon does n...

Page 70: ...from Market Vimar Group Tapping the icon with the name of the application chosen for activation in this case and then the icon displays a pop up with which you can proceed with your request for activation or cancel the operation ...

Page 71: ...n again After a few seconds a screen will appear for installing the application in this case Secuviewer Continue with the operation leaving all the provided options selected and tap Install On completion Application Installed will be displayed Tap the End icon to complete installation The new application is installed and ready for use Please note the procedure and operations described above apply ...

Page 72: ...e installed CAUTION To prevent injury the appliance must be secured to the wall as described in the installation instructions Above the power supply there must be a bipolar circuit breaker that is easily accessible with a contact gap of at least 3 mm 5 REGULATORY COMPLIANCE LV directive EMC directive Standards EN 60950 1 EN 61000 6 1 EN 61000 6 3 Installation rules Regulatory compliance ...

Page 73: ...71 ...

Page 74: ...21553 installatore EN 03 1307 VIMAR Marostica Italy Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax 39 0424 488 709 http www vimar com ...